FNOX FIO Disk Benchmarks,
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",61287,59830,59963
"vmware-v7000_2-ssd-prod-norepl-conf",60517,63947,61796
"vmware-v7000_2-ssd-prod-norepl-raid6",71455,70406,69880
"proact-netapp-ssd-sto1",95397,99160,99261
"proact-netapp-ssd-sto4",51673,51552,51043
"proact-netapp-ssd-sto1-lazy-thick",75650,73034,73217
"proact-netapp-ssd-sto1-eager-thick",76630,76781,77087
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",15329,16494,15940,16189
"vmware-v7000_2-ssd-prod-norepl-conf",20275,20975,20613
"vmware-v7000_2-ssd-prod-norepl-raid6",21364,22026,21794
"proact-netapp-ssd-sto1",61445,61900,62541
"proact-netapp-ssd-sto4",56926,55890,55669
"proact-netapp-ssd-sto1-lazy-thick",60916,61979,62546
"proact-netapp-ssd-sto1-eager-thick",60383,62242,62288
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",76975,76178,75397
"vmware-v7000_2-ssd-prod-norepl-conf",78661,79661,81408
"vmware-v7000_2-ssd-prod-norepl-raid6",82489,75656,83606,83411,82188,83498
"proact-netapp-ssd-sto1",96613,97369,94891
"proact-netapp-ssd-sto4",53316,52665,52771
"proact-netapp-ssd-sto1-lazy-thick",95884,98523,96262
"proact-netapp-ssd-sto1-eager-thick",95976,93507,99561,98450
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",21828,22340,22097
"vmware-v7000_2-ssd-prod-norepl-conf",29020,29581,29657
"vmware-v7000_2-ssd-prod-norepl-raid6",32112,33077,33367
"proact-netapp-ssd-sto1",36280,34424,42714,38316,34433,43529,37991,34338,41133,38517,34255,40726,39521,33540,40506
"proact-netapp-ssd-sto4",16712,16811,16841
"proact-netapp-ssd-sto1-lazy-thick",33821,43498,40954,34172,43473,38718,33887,43664,38276,34291,40941,38963,33522,40061,39667
"proact-netapp-ssd-sto1-eager-thick",41510,34063,30500,23068,35190,41997,38021,34221,41694,38919,34347,40342,40465,33883,40582
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",239.43,246.323,236.2
"vmware-v7000_2-ssd-prod-norepl-conf",251.847,245.166,255.397
"vmware-v7000_2-ssd-prod-norepl-raid6",281.184,284.276,284.937
"proact-netapp-ssd-sto1",387.637,391.341,386.903
"proact-netapp-ssd-sto4",206.364,206.187,206.013
"proact-netapp-ssd-sto1-lazy-thick",304.189,309.814,306.876
"proact-netapp-ssd-sto1-eager-thick",310.853,306.757,312.129
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",65.86,66.107,65.539
"vmware-v7000_2-ssd-prod-norepl-conf",82.821,82.865,81.29
"vmware-v7000_2-ssd-prod-norepl-raid6",88.204,86.669,86.454
"proact-netapp-ssd-sto1",250.405,250.889,248.868
"proact-netapp-ssd-sto4",224.82,220.843,221.094
"proact-netapp-ssd-sto1-lazy-thick",246.397,248.65,245.644
"proact-netapp-ssd-sto1-eager-thick",248.8,246.855,246.999
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",303.16,306.165,289.775
"vmware-v7000_2-ssd-prod-norepl-conf",316.708,322.195,325.365
"vmware-v7000_2-ssd-prod-norepl-raid6",326.987,325.334,330.385
"proact-netapp-ssd-sto1",377.013,373.409,378.486
"proact-netapp-ssd-sto4",210.828,211.344,212.256
"proact-netapp-ssd-sto1-lazy-thick",382.171,388.577,386.937
"proact-netapp-ssd-sto1-eager-thick",397.484,393.477,394.814
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"vmware-v7000_2-ssd-prod-repl",86.503,88.762,88.674
"vmware-v7000_2-ssd-prod-norepl-conf",117.711,117.678,118.503
"vmware-v7000_2-ssd-prod-norepl-raid6",133.989,127.926,134.309
"proact-netapp-ssd-sto1",152.577,137.265,175.946,161.814,135.719,174.689,156.267,135.827,172.45,151.336,135.231,166.379,153.492,136.199,163.17
"proact-netapp-ssd-sto4",67.624,67.069,68.251
"proact-netapp-ssd-sto1-lazy-thick",172.825,164.528,136.078,166.127,154.197,139.052,165.086,155.945,138.082,166.738,160.457,140.18,175.397,159.662,133.548
"proact-netapp-ssd-sto1-eager-thick",148.219,137.019,174.478,158.814,137.963,176.12,151.434,134.945,173.952,152.333,136.085,167.392,159.838,135.893,172.079