fiotest1

KVM testing on Ubuntu 18.04 via the Phoronix Test Suite.

Compare your own system(s) to this result file with the Phoronix Test Suite by running the command: phoronix-test-suite benchmark 2002259-RA-FIOTEST1394
Jump To Table - Results

Statistics

Remove Outliers Before Calculating Averages

Graph Settings

Prefer Vertical Bar Graphs

Multi-Way Comparison

Condense Multi-Option Tests Into Single Result Graphs

Table

Show Detailed System Result Table

Run Management

Result
Identifier
Performance Per
Dollar
Date
Run
  Test
  Duration
fio test prox6
February 24 2020
  12 Hours, 42 Minutes
Only show results matching title/arguments (delimit multiple options with a comma):
Do not show results matching title/arguments (delimit multiple options with a comma):


fiotest1 KVM testing on Ubuntu 18.04 via the Phoronix Test Suite. fio test prox6: Processor: Intel Xeon E3-12xx v2 @ 3.50GHz (6 Cores), Motherboard: QEMU Standard PC (i440FX + PIIX 1996) (rel-1.12.1-0-ga5cab58e9a3f-prebuilt.qemu.org BIOS), Chipset: Intel 440FX- 82441FX PMC, Memory: 4096MB, Disk: 34GB QEMU HDD, Graphics: EFI VGA, Network: Red Hat Virtio device OS: Ubuntu 18.04, Kernel: 4.15.0-38-generic (x86_64), Compiler: GCC 7.4.0, File-System: ext4, Screen Resolution: 800x600, System Layer: KVM Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3885 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 218 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 438 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 845 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1613 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3029 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3799 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 216 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 432 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 206 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 18.98 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 33.80 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1493 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 409 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3468 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3675 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3771 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 847 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1614 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2953 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 59.75 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 89.47 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 115 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 204 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 18.78 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 36.90 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 756 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1353 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1424 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1403 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 205 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 398 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1064 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 239 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 379 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3434 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3716 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3820 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 199 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 209 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 201 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 57.97 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 93.70 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 118 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1474 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 762 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1370 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1449 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 579 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 745 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 905 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1056 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 244 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 406 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 191 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 206 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1465 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1382 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1411 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1010 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1048 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1052 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 595 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 766 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 919 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3772 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 216 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 445 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1019 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1035 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1069 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 855 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1608 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2997 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3848 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 210 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 429 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 525 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 343 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 524 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1452 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 202 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 396 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3485 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3773 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3892 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 873 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1629 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2932 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 663 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 736 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 713 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 520 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 340 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 507 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 780 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1365 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1486 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1443 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 405 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1076 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 278 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 457 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3533 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3835 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3776 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 731 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 678 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 503 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 659 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 775 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 710 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1493 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1437 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1495 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 781 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1362 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1457 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 657 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 862 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 981 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1077 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 281 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 462 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 778 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 689 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 564 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1499 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1410 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1460 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1067 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1024 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1042 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 666 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 839 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1020 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1072 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1059 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1068 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3882 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55867 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 56067 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54100 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51633 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48467 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3796 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55400 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55033 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 203 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4876 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4323 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1489 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52867 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52300 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27400 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14700 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7538 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54167 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51667 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 47267 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3827 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2860 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1842 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 201 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4803 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4717 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48367 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42933 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 22767 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1399 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52400 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 50900 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1060 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 61067 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48233 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27467 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14867 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7637 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1584 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 831 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 398 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3707 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2995 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1876 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11567 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5891 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2891 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48767 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43833 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23200 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 37057 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23833 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14467 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1052 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 62367 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51933 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1525 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 822 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 410 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11733 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5526 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2819 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8075 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4190 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2099 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 38075 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 24500 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3768 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54833 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 56700 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8145 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4137 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2135 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51442 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 47967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3844 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 53392 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 521 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 87642 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 67117 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 50700 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27867 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14767 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7779 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55533 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52025 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 46933 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42350 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23525 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11392 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 516 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 86733 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 64950 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 49933 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1439 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52400 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1073 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 71233 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 58533 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 28267 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 15367 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7548 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5847 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2706 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1002 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42100 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 24800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11350 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11300 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5743 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2987 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 49667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43583 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23311 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42033 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27600 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 15700 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1073 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 71967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 59100 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 6223 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2754 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1124 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11633 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5639 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2917 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8530 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4094 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2080 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42633 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 26833 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 16300 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8576 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4233 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2132 |========================================================