FNOX FIO Disk Benchmarks

Virtual and Physical Appliance Disk Performance Testing

Compare your own system(s) to this result file with the Phoronix Test Suite by running the command: phoronix-test-suite benchmark 1603108-GA-1603092GA84
Jump To Table - Results

View

Do Not Show Noisy Results
Do Not Show Results With Incomplete Data
Do Not Show Results With Little Change/Spread
List Notable Results

Statistics

Show Overall Harmonic Mean(s)
Show Overall Geometric Mean
Show Wins / Losses Counts (Pie Chart)
Normalize Results
Remove Outliers Before Calculating Averages

Graph Settings

Force Line Graphs Where Applicable
Convert To Scalar Where Applicable
Prefer Vertical Bar Graphs

Additional Graphs

Show Perf Per Core/Thread Calculation Graphs Where Applicable
Show Perf Per Clock Calculation Graphs Where Applicable

Multi-Way Comparison

Condense Multi-Option Tests Into Single Result Graphs

Table

Show Detailed System Result Table

Run Management

Highlight
Result
Hide
Result
Result
Identifier
Performance Per
Dollar
Date
Run
  Test
  Duration
physical-ssd-raid1
February 17 2016
 
V7000gen2-ssd-raid1
February 17 2016
 
V7000-hdd-raid10
March 01 2016
 
physical-ibm840-fc
March 02 2016
 
kvm-ibm840-directsync
March 03 2016
 
kvm-ibm840-nocache
March 04 2016
 
kvm-ibm840-writeback
March 07 2016
 
kvm-ibm840-writethrough
March 07 2016
 
vmware-ssd-raid1
March 08 2016
 
vmware-ibm840-fc
March 09 2016
 
vmware-ibm840-rr
March 10 2016
 
Invert Hiding All Results Option
 

Only show results where is faster than
Only show results matching title/arguments (delimit multiple options with a comma):
Do not show results matching title/arguments (delimit multiple options with a comma):


FNOX FIO Disk Benchmarks, "Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS", Higher Results Are Better "physical-ssd-raid1",116400,116918,118346 "V7000gen2-ssd-raid1",81572,81575,81278 "V7000-hdd-raid10",18071,54493,38138,28832,44814,68191 "physical-ibm840-fc",124645,124728,140966,130112,124272,124179 "kvm-ibm840-directsync",117034,117903,117007 "kvm-ibm840-nocache",116966,117603,113350 "kvm-ibm840-writeback",190597,195785,192214 "kvm-ibm840-writethrough",198549,204548,201618 "vmware-ssd-raid1",125824,124871,125890 "vmware-ibm840-fc",100421,100822,100469 "vmware-ibm840-rr",101026,101007,100980 "Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS", Higher Results Are Better "physical-ssd-raid1",114081,114148,114352 "V7000gen2-ssd-raid1",62710,64667,62289 "V7000-hdd-raid10",4344,5586,5241,7604,6020,6927 "physical-ibm840-fc",102220,102240,102236 "kvm-ibm840-directsync",101980,102053,101942 "kvm-ibm840-nocache",102361,102086,102105 "kvm-ibm840-writeback",196803,206534,199858 "kvm-ibm840-writethrough",204494,201169,201377 "vmware-ssd-raid1",124311,124083,123290 "vmware-ibm840-fc",100789,100369,100465 "vmware-ibm840-rr",100926,101165,101195 "Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s", Higher Results Are Better "physical-ssd-raid1",467.379,456.576,470.079 "V7000gen2-ssd-raid1",316.452,315.949,324.824 "V7000-hdd-raid10",254.509,279.083,249.366,210.603,256.14,212.174 "physical-ibm840-fc",498.942,496.327,499.516 "kvm-ibm840-directsync",477.371,462.322,462.618 "kvm-ibm840-nocache",460.446,468.252,469.478 "kvm-ibm840-writeback",763.278,797.517,781.623 "kvm-ibm840-writethrough",796.308,805.795,814.881 "vmware-ssd-raid1",503.811,503.449,503.848 "vmware-ibm840-fc",402.115,403.496,401.824 "vmware-ibm840-rr",403.841,403.424,403.758 "Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s", Higher Results Are Better "physical-ssd-raid1",457.529,513.485,524.544,455.81,520.461,482.504 "V7000gen2-ssd-raid1",258.268,253.226,256.217 "V7000-hdd-raid10",20.663,42.22,45.273,20.816,17.801,24.398 "physical-ibm840-fc",408.868,408.946,409.122 "kvm-ibm840-directsync",408.19,408.116,402.251 "kvm-ibm840-nocache",409.632,408.151,408.662 "kvm-ibm840-writeback",792.708,762.864,729.092,778.607,772.575 "kvm-ibm840-writethrough",776.114,800.664,808.883 "vmware-ssd-raid1",494.782,494.107,493.949 "vmware-ibm840-fc",401.485,403.765,401.841 "vmware-ibm840-rr",404.532,404.327,402.837 "Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s", Higher Results Are Better "physical-ssd-raid1",138.724,137.401,135.954 "V7000gen2-ssd-raid1",165.006,163.516,158.143 "V7000-hdd-raid10",53.168,57.496,53.819,54.371,52.039,55.277 "physical-ibm840-fc",500.727,498.3,501.355 "kvm-ibm840-directsync",262.597,263.061,265.293 "kvm-ibm840-nocache",399.722,446.451,437.39,442.85,435.171,402.42 "kvm-ibm840-writeback",765.798,766.368,773.307 "kvm-ibm840-writethrough",96.159,97.551,96.706 "vmware-ssd-raid1",128.553,128.562,128.571 "vmware-ibm840-fc",494.663,493.67,494.769 "vmware-ibm840-rr",492.808,491.244,491.996 "Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS", Higher Results Are Better "physical-ssd-raid1",37046,35397,35162 "V7000gen2-ssd-raid1",39891,41184,40849 "V7000-hdd-raid10",13499,13916,14065 "physical-ibm840-fc",125079,124154,124209 "kvm-ibm840-directsync",56149,55170,55392 "kvm-ibm840-nocache",110983,116027,111153 "kvm-ibm840-writeback",192266,188616,192770 "kvm-ibm840-writethrough",25086,24310,24260 "vmware-ssd-raid1",32447,32122,32180 "vmware-ibm840-fc",123784,123690,123559 "vmware-ibm840-rr",123040,123154,123017 "Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS", Higher Results Are Better "physical-ssd-raid1",103041,104565,103359 "V7000gen2-ssd-raid1",55109,55805,54505 "V7000-hdd-raid10",17559,19492,18166,19333,19239,20531 "physical-ibm840-fc",156118,161717,155458 "kvm-ibm840-directsync",77779,78102,78235 "kvm-ibm840-nocache",148450,147067,149440 "kvm-ibm840-writeback",213501,243131,224389,216625,216831,251330 "kvm-ibm840-writethrough",61594,61574,61935 "vmware-ssd-raid1",103979,103571,103938 "vmware-ibm840-fc",125339,125175,125393 "vmware-ibm840-rr",125276,125304,125364 "Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s", Higher Results Are Better "physical-ssd-raid1",411.356,413.537,413.41 "V7000gen2-ssd-raid1",223.959,221.173,225.798 "V7000-hdd-raid10",77.772,74.419,76.638 "physical-ibm840-fc",644.542,647.073,643.292 "kvm-ibm840-directsync",369.286,376.414,369.893 "kvm-ibm840-nocache",586.595,576.919,596.838 "kvm-ibm840-writeback",849.379,930.306,900.948,824.977,894.647,896.412 "kvm-ibm840-writethrough",247.52,245.882,247.151 "vmware-ssd-raid1",415.17,415.82,415.444 "vmware-ibm840-fc",500.477,497.945,499.97 "vmware-ibm840-rr",499.118,501.243,501.37