Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 1602109-HA-1602107HA75
FNOX SAN Testing FIO,
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",50945,51655,51437
"V7000gen2-ssd-raid5",50548,50081,51028
"V7000-hdd-raid10",6823,29037,10910,5083,7305,7978
"V7000gen2-ssd-raid10",66771,66619,67662
"V7000gen2-hdd-raid10",6414,22974,49189,49730,50381,50253
"V7000gen2-hdd-raid10-comp",51765,57561,58135,58130,58113,57671
"ibm840-flash",58411,59235,59762
"V7000gen2-hdd-raid10-round2",10705,57589,58509,58210,58207,57846
"ibm840-flash-round2",55456,56009,56083
"ibm840-flash-round3",58743,58445,59129
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",19128,19837,19887
"V7000gen2-ssd-raid5",38619,38697,38973
"V7000-hdd-raid10",14273,11991,14600,13466,14525,13522
"V7000gen2-ssd-raid10",53976,53998,53517
"V7000gen2-hdd-raid10",31729,32292,31721
"V7000gen2-hdd-raid10-comp",13236,18758,17918,18358,18112,18717
"ibm840-flash",47192,47193,47638
"V7000gen2-hdd-raid10-round2",38866,40584,40199
"ibm840-flash-round2",55416,55576,55460
"ibm840-flash-round3",47485,48306,48216
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",66207,69201,69027
"V7000gen2-ssd-raid5",71078,70607,70886
"V7000-hdd-raid10",56548,59416,60323
"V7000gen2-ssd-raid10",90125,90438,80703,89889,88686,89898
"V7000gen2-hdd-raid10",72491,71493,71316
"V7000gen2-hdd-raid10-comp",76590,76694,75849
"ibm840-flash",82527,81886,83311
"V7000gen2-hdd-raid10-round2",83259,84201,83989
"ibm840-flash-round2",82373,77300,77514,76773
"ibm840-flash-round3",80333,81046,80479
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",27672,28575,28575
"V7000gen2-ssd-raid5",44151,44526,44729
"V7000-hdd-raid10",15645,14453,15514,16226,16063,16303
"V7000gen2-ssd-raid10",66343,66151,65681
"V7000gen2-hdd-raid10",45169,44638,45008
"V7000gen2-hdd-raid10-comp",13835,16068,14225,15342,13914,17089
"ibm840-flash",58402,57197,59083
"V7000gen2-hdd-raid10-round2",49517,49044,49630
"ibm840-flash-round2",54107,59625,58705,59907,59306,59593
"ibm840-flash-round3",59197,59182,59415
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",206.335,206.535,206.284
"V7000gen2-ssd-raid5",204.992,203.51,207.976
"V7000-hdd-raid10",103.633,190.247,138.204,96.394,195.888,181.748
"V7000gen2-ssd-raid10",273.835,273.498,275.178
"V7000gen2-hdd-raid10",202.013,204.051,203.982
"V7000gen2-hdd-raid10-comp",233.379,230.627,233.161
"ibm840-flash",235.791,237.937,238.593
"V7000gen2-hdd-raid10-round2",233.914,231.849,233.482
"ibm840-flash-round2",225.616,225.237,224.679
"ibm840-flash-round3",236.361,236.559,236.711
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",78.612,79.141,78.885
"V7000gen2-ssd-raid5",154.756,154.456,155.034
"V7000-hdd-raid10",58.852,52.071,58.61,52.254,58.056,51.35
"V7000gen2-ssd-raid10",217.249,217.391,216.626
"V7000gen2-hdd-raid10",128.469,128.571,129.697
"V7000gen2-hdd-raid10-comp",73.31,72.155,73.454
"ibm840-flash",188.917,188.974,188.905
"V7000gen2-hdd-raid10-round2",162.638,161.961,162.818
"ibm840-flash-round2",221.292,220.365,220.439
"ibm840-flash-round3",190.72,190.529,192.629
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",288.081,290.927,277.544
"V7000gen2-ssd-raid5",282.95,286.47,294.516
"V7000-hdd-raid10",205.54,213.583,225.046,224.382,230.299,221.243
"V7000gen2-ssd-raid10",356.568,338.94,361.072
"V7000gen2-hdd-raid10",288.736,285.238,289.953
"V7000gen2-hdd-raid10-comp",303.947,304.501,307.222
"ibm840-flash",331.996,332.512,329.097
"V7000gen2-hdd-raid10-round2",335.075,334.098,330.298
"ibm840-flash-round2",318.92,298.564,302.849
"ibm840-flash-round3",324.812,324.643,325.779
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",112.672,111.713,113.598
"V7000gen2-ssd-raid5",177.028,178.461,178.348
"V7000-hdd-raid10",65.28,65.49,65.782
"V7000gen2-ssd-raid10",264.891,264.122,261.272
"V7000gen2-hdd-raid10",182.133,179.865,182.422
"V7000gen2-hdd-raid10-comp",57.495,63.334,60.177,65.236,60.921,65.096
"ibm840-flash",234.38,234.479,232.225
"V7000gen2-hdd-raid10-round2",199.82,201.26,199.099
"ibm840-flash-round2",235.406,237.179,228.377
"ibm840-flash-round3",238.316,237.162,236.037