FNOX SAN Testing FIO
FNOX SAN Testing fio disk
V7000gen2-ssd-raid5-comp:
Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk
OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware
V7000gen2-ssd-raid5:
Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk
OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware
V7000-hdd-raid10:
Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk
OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware
V7000gen2-ssd-raid10:
Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk
OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware
Flexible IO Tester 2.1.13
Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS
IOPS > Higher Is Better
V7000gen2-ssd-raid5-comp . 51346 |==================================
V7000gen2-ssd-raid5 ...... 50552 |==================================
V7000-hdd-raid10 ......... 11189 |========
V7000gen2-ssd-raid10 ..... 67017 |=============================================
Flexible IO Tester 2.1.13
Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s
MB/s > Higher Is Better
V7000gen2-ssd-raid5-comp . 206.38 |=================================
V7000gen2-ssd-raid5 ...... 205.49 |=================================
V7000-hdd-raid10 ......... 151.02 |========================
V7000gen2-ssd-raid10 ..... 274.17 |============================================
Flexible IO Tester 2.1.13
Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS
IOPS > Higher Is Better
V7000gen2-ssd-raid5-comp . 19617 |================
V7000gen2-ssd-raid5 ...... 38763 |================================
V7000-hdd-raid10 ......... 13730 |===========
V7000gen2-ssd-raid10 ..... 53830 |=============================================
Flexible IO Tester 2.1.13
Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s
MB/s > Higher Is Better
V7000gen2-ssd-raid5-comp . 78.88 |================
V7000gen2-ssd-raid5 ...... 154.75 |===============================
V7000-hdd-raid10 ......... 55.20 |===========
V7000gen2-ssd-raid10 ..... 217.09 |============================================
Flexible IO Tester 2.1.13
Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS
IOPS > Higher Is Better
V7000gen2-ssd-raid5-comp . 68145 |===================================
V7000gen2-ssd-raid5 ...... 70857 |====================================
V7000-hdd-raid10 ......... 58762 |==============================
V7000gen2-ssd-raid10 ..... 88290 |=============================================
Flexible IO Tester 2.1.13
Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s
MB/s > Higher Is Better
V7000gen2-ssd-raid5-comp . 285.52 |====================================
V7000gen2-ssd-raid5 ...... 287.98 |====================================
V7000-hdd-raid10 ......... 220.02 |===========================
V7000gen2-ssd-raid10 ..... 352.19 |============================================
Flexible IO Tester 2.1.13
Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS
IOPS > Higher Is Better
V7000gen2-ssd-raid5-comp . 28274 |===================
V7000gen2-ssd-raid5 ...... 44469 |==============================
V7000-hdd-raid10 ......... 15701 |===========
V7000gen2-ssd-raid10 ..... 66058 |=============================================
Flexible IO Tester 2.1.13
Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s
MB/s > Higher Is Better
V7000gen2-ssd-raid5-comp . 112.66 |===================
V7000gen2-ssd-raid5 ...... 177.95 |==============================
V7000-hdd-raid10 ......... 65.52 |===========
V7000gen2-ssd-raid10 ..... 263.43 |============================================