FNOX SAN Testing FIO,
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",50945,51655,51437
"V7000gen2-ssd-raid5",50548,50081,51028
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",19128,19837,19887
"V7000gen2-ssd-raid5",38619,38697,38973
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",66207,69201,69027
"V7000gen2-ssd-raid5",71078,70607,70886
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",27672,28575,28575
"V7000gen2-ssd-raid5",44151,44526,44729
"Flexible IO Tester 2.1.13 - Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",206.335,206.535,206.284
"V7000gen2-ssd-raid5",204.992,203.51,207.976
"Flexible IO Tester 2.1.13 - Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",78.612,79.141,78.885
"V7000gen2-ssd-raid5",154.756,154.456,155.034
"Flexible IO Tester 2.1.13 - Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",288.081,290.927,277.544
"V7000gen2-ssd-raid5",282.95,286.47,294.516
"Flexible IO Tester 2.1.13 - Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s",
Higher Results Are Better
"V7000gen2-ssd-raid5-comp",112.672,111.713,113.598
"V7000gen2-ssd-raid5",177.028,178.461,178.348