r6d12c256drbd2mpio

Running pts/tiobench-1.2.0 via the Phoronix Test Suite.

Compare your own system(s) to this result file with the Phoronix Test Suite by running the command: phoronix-test-suite benchmark 1507084-DE-R6D12C25675
Jump To Table - Results

View

Do Not Show Noisy Results
Do Not Show Results With Incomplete Data
Do Not Show Results With Little Change/Spread
List Notable Results

Statistics

Show Overall Harmonic Mean(s)
Show Overall Geometric Mean
Show Wins / Losses Counts (Pie Chart)
Normalize Results
Remove Outliers Before Calculating Averages

Graph Settings

Force Line Graphs Where Applicable
Convert To Scalar Where Applicable
Prefer Vertical Bar Graphs

Multi-Way Comparison

Condense Multi-Option Tests Into Single Result Graphs

Table

Show Detailed System Result Table

Run Management

Highlight
Result
Hide
Result
Result
Identifier
Performance Per
Dollar
Date
Run
  Test
  Duration
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware
April 26 2015
 
Virtual disk
April 26 2015
 
Invert Hiding All Results Option
 
Only show results matching title/arguments (delimit multiple options with a comma):
Do not show results matching title/arguments (delimit multiple options with a comma):


r6d12c256drbd2mpio, "Dbench 4.0 - Client Count: 1", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",206.708,206.713,204.963 "Dbench 4.0 - Client Count: 6", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",337.684,338.804,338.34 "Dbench 4.0 - Client Count: 12", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",360.007,362.183,357.324 "Dbench 4.0 - Client Count: 48", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",401.258,396.84,402.346 "Dbench 4.0 - Client Count: 128", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",402.073,414.924,412.581 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 256MB - Thread Count: 8", Higher Results Are Better "Virtual disk",11.297,13.428,11.11,13.441,11.208,13.401 "Dbench 4.0 - Client Count: 256", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",312.541,355.636,341.526,362.569,351.719,349.47 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 64MB - Thread Count: 16", Higher Results Are Better "Virtual disk",12.491,12.432,12.491 "IOzone 3.405 - Record Size: 1MB - File Size: 2GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",111.845703125,111.9326171875,111.7705078125 "IOzone 3.405 - Record Size: 1MB - File Size: 4GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",105.0400390625,105.6005859375,105.7666015625 "IOzone 3.405 - Record Size: 1MB - File Size: 8GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",108.662109375,105.9658203125,107.673828125 "IOzone 3.405 - Record Size: 4Kb - File Size: 2GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",111.708984375,111.0498046875,111.6748046875 "IOzone 3.405 - Record Size: 4Kb - File Size: 4GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",105.93359375,105.62109375,104.3310546875 "IOzone 3.405 - Record Size: 4Kb - File Size: 8GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",106.9814453125,106.9462890625,108.2705078125 "IOzone 3.405 - Record Size: 1MB - File Size: 2GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",93.4345703125,88.490234375,90.7275390625 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 64MB - Thread Count: 32", Higher Results Are Better "Virtual disk",21.257,21.653,20.434 "IOzone 3.405 - Record Size: 1MB - File Size: 4GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",95.6171875,90.5771484375,94.8828125 "IOzone 3.405 - Record Size: 1MB - File Size: 8GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",93.4130859375,92.0087890625,92.5810546875 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 256MB - Thread Count: 32", Higher Results Are Better "Virtual disk",20.575,21.942,20.957 "IOzone 3.405 - Record Size: 4Kb - File Size: 2GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",90.591796875,93.439453125,87.4169921875 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 32MB - Thread Count: 16", Higher Results Are Better "Virtual disk",23.084,27.568,13.331,15.399,14.289,15.204 "IOzone 3.405 - Record Size: 4Kb - File Size: 4GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",92.6259765625,91.8662109375,93.494140625 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 32MB - Thread Count: 8", Higher Results Are Better "Virtual disk",11.136,17.647,17.235,11.305,17.631,17.247 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 64MB - Thread Count: 32", Higher Results Are Better "Virtual disk",112.181,111.973,112.033 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 32MB - Thread Count: 4", Higher Results Are Better "Virtual disk",11.303,10.037,10.882,9.916,10.876,9.844 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 128MB - Thread Count: 4", Higher Results Are Better "Virtual disk",9.942,11.177,9.894,11.163,9.945,11.297 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 256MB - Thread Count: 4", Higher Results Are Better "Virtual disk",9.963,10.926,10.055,10.886,9.884,10.83 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 128MB - Thread Count: 16", Higher Results Are Better "Virtual disk",112.193,112.124,111.975 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 256MB - Thread Count: 16", Higher Results Are Better "Virtual disk",112.042,111.988,111.999 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 128MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1732.056,1831.266,1751.952 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 256MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1815.664,1927.798,1860.185 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 64MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1769.667,1597.105,1648.72,1704.111,1795.855,1667.568 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 128MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1777.414,1751.146,1651.554,1849.384,1846.396,1843.557 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 64MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1866.501,1754.638,1838.869 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 32MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1776.581,1779.285,1730.7 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 32MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1820.25,1838.473,1637.289,1820.199,1823.648,1818.259 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 64MB - Thread Count: 4", Higher Results Are Better "Virtual disk",9.972,11.231,10.076,9.895,11.154,9.86 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 256MB - Thread Count: 8", Higher Results Are Better "Virtual disk",112.197,112.029,111.07 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 64MB - Thread Count: 8", Higher Results Are Better "Virtual disk",11.196,11.928,11.79 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 32MB - Thread Count: 16", Higher Results Are Better "Virtual disk",1576.966,1750.326,1628.633,1542.861,1706.968,1695.926 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 128MB - Thread Count: 32", Higher Results Are Better "Virtual disk",111.886,108.548,111.99 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 32MB - Thread Count: 32", Higher Results Are Better "Virtual disk",1733.355,1663.699,1640.035 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 256MB - Thread Count: 32", Higher Results Are Better "Virtual disk",112.123,111.897,112.013 "Threaded I/O Tester 0.3.3 - Test: Read - Size Per Thread: 64MB - Thread Count: 16", Higher Results Are Better "Virtual disk",1724.019,1635.012,1699.148 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 128MB - Thread Count: 8", Higher Results Are Better "Virtual disk",11.242,16.016,11.299,15.819,11.304,15.778 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 64MB - Thread Count: 32", Higher Results Are Better "Virtual disk",23.301,24.796,24.272 "IOzone 3.405 - Record Size: 4Kb - File Size: 8GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",92.4755859375,93.3505859375,92.73046875 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 128MB - Thread Count: 32", Higher Results Are Better "Virtual disk",27.021,24.569,26.747,26.115,26.463,26.531 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 256MB - Thread Count: 32", Higher Results Are Better "Virtual disk",25.31,24.246,25.356 "IOzone 3.405 - Record Size: 64Kb - File Size: 2GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",111.953125,111.9501953125,112.0205078125 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 32MB - Thread Count: 32", Higher Results Are Better "Virtual disk",23.304,24.293,22.694 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 32MB - Thread Count: 32", Higher Results Are Better "Virtual disk",20.91,21.994,20.613 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 256MB - Thread Count: 16", Higher Results Are Better "Virtual disk",12.43,12.379,12.362 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 32MB - Thread Count: 16", Higher Results Are Better "Virtual disk",1488.875,1584.645,1515.335 "IOzone 3.405 - Record Size: 64Kb - File Size: 4GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",110.6640625,110.369140625,111.9345703125 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 32MB - Thread Count: 4", Higher Results Are Better "Virtual disk",18.802,13.43,17.657,10.749,11.663,18.822 "IOzone 3.405 - Record Size: 64Kb - File Size: 8GB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",108.7421875,106.7529296875,107.64453125 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 128MB - Thread Count: 16", Higher Results Are Better "Virtual disk",179.666,164.572,95.367,166.726,165.916,152.329 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 64MB - Thread Count: 4", Higher Results Are Better "Virtual disk",17.584,15.734,13.949,11.565,15.467,11.909 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 64MB - Thread Count: 8", Higher Results Are Better "Virtual disk",15.553,12.336,15.142,12.944,15.627,12.597 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 256MB - Thread Count: 8", Higher Results Are Better "Virtual disk",12.225,15.739,12.18,14.77,12.987,15.491 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 64MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1514.784,1519.646,1496.074 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 256MB - Thread Count: 32", Higher Results Are Better "Virtual disk",5.836,6.1,5.918 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 128MB - Thread Count: 8", Higher Results Are Better "Virtual disk",12.939,12.906,13.273 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 32MB - Thread Count: 16", Higher Results Are Better "Virtual disk",19.111,20.015,11.861,12.475,12.524,12.509 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 32MB - Thread Count: 32", Higher Results Are Better "Virtual disk",1533.046,1477.961,1433.881 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 256MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1319.345,1186.859,1281.473,1265.9,1150.25,1391.61 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 256MB - Thread Count: 8", Higher Results Are Better "Virtual disk",159.613,125.543,30.782,149.788,152.143,155.769 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 128MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1258.052,1295.068,1436.782,1481.464,1336.841,1414.539 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 128MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1327.415,1195.486,1458.508,1459.871,1414.923,1373.506 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 64MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1389.754,1347.912,1483.222,1485.054,1435.132,1342.469 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 128MB - Thread Count: 32", Higher Results Are Better "Virtual disk",11.756,12.964,10.026,12.024,9.882,9.473 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 64MB - Thread Count: 16", Higher Results Are Better "Virtual disk",1426.941,1267.389,1034.083,1483.961,1331.402,1418.488 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 256MB - Thread Count: 16", Higher Results Are Better "Virtual disk",13.37,11.59,11.398,9.595,12.289,11.151 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 64MB - Thread Count: 32", Higher Results Are Better "Virtual disk",168.627,136.374,121.331,139.071,119.222,135.261 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 128MB - Thread Count: 4", Higher Results Are Better "Virtual disk",18.279,12.166,20.584,11.8,19.233,15.466 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 32MB - Thread Count: 4", Higher Results Are Better "Virtual disk",1552.255,1582.759,1595.853 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 256MB - Thread Count: 4", Higher Results Are Better "Virtual disk",12.375,18.33,15.899,18.06,14.305,20.199 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 32MB - Thread Count: 8", Higher Results Are Better "Virtual disk",13.727,21.834,12.826,12.508,15.708,17.713 "IOzone 3.405 - Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",2335.39453125,2686.41015625,2678.6494140625,2671.228515625,2680.150390625,2658.869140625 "IOzone 3.405 - Record Size: 4Kb - File Size: 512MB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",2361.7744140625,2363.859375,2368.3857421875 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 64MB - Thread Count: 16", Higher Results Are Better "Virtual disk",13.979,14.059,14.19 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 128MB - Thread Count: 16", Higher Results Are Better "Virtual disk",12.395,12.37,12.423 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 128MB - Thread Count: 16", Higher Results Are Better "Virtual disk",16.312,17.171,15.561,16.878,15.959,17.369 "Threaded I/O Tester 0.3.3 - Test: Write - Size Per Thread: 128MB - Thread Count: 32", Higher Results Are Better "Virtual disk",20.933,21.69,20.698 "Threaded I/O Tester 0.3.3 - Test: Random Write - Size Per Thread: 256MB - Thread Count: 16", Higher Results Are Better "Virtual disk",15.711,17.208,14.739,16.973,15.027,16.958 "Threaded I/O Tester 0.3.3 - Test: Random Read - Size Per Thread: 32MB - Thread Count: 8", Higher Results Are Better "Virtual disk",1443.551,1596.098,1570.904,1512.878,1585.248,1569.563 "IOzone 3.405 - Record Size: 64Kb - File Size: 2GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",180.4697265625,103.9423828125,102.1328125,100.9462890625,101.62890625,100.9306640625 "IOzone 3.405 - Record Size: 64Kb - File Size: 4GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",103.3369140625,95.13671875,95.8125,95.7001953125,96.6923828125 "IOzone 3.405 - Record Size: 64Kb - File Size: 8GB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",97.880859375,95.0595703125,95.1005859375 "IOzone 3.405 - Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",170.7119140625,182.259765625,169.5673828125,170.5185546875 "IOzone 3.405 - Record Size: 4Kb - File Size: 512MB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",171.701171875,158.9716796875,157.39453125,162.3701171875,170.5712890625,174.8701171875 "IOzone 3.405 - Record Size: 64Kb - File Size: 512MB - Disk Test: Read Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",2626.974609375,2651.859375,2647.6513671875 "IOzone 3.405 - Record Size: 64Kb - File Size: 512MB - Disk Test: Write Performance", Higher Results Are Better "RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware",173.927734375,176.2939453125,184.3369140625