VMware testing on CentOS 6.4 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 1306258-UT-YMMRCENT683
YMMR-cent64
VMware testing on CentOS 6.4 via the Phoronix Test Suite.
16384 MB DRAM:
Processor: 2 x Intel Xeon E5-2470 0 @ 2.29GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 16384 MB DRAM, Disk: 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS 6.4, Kernel: 2.6.32-358.el6.x86_64 (x86_64), Display Driver: vmware 12.0.2, Compiler: GCC 4.4.7 20120313, File-System: ext4, System Layer: VMware
Intel Xeon E5-2470 0:
Processor: 2 x Intel Xeon E5-2470 0 @ 2.29GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 16384 MB DRAM, Disk: 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS 6.4, Kernel: 2.6.32-358.el6.x86_64 (x86_64), Display Driver: vmware 12.0.2, Compiler: GCC 4.4.7 20120313, File-System: ext4, System Layer: VMware
Virtual disk:
Processor: 2 x Intel Xeon E5-2470 0 @ 2.29GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 16384 MB DRAM, Disk: 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS 6.4, Kernel: 2.6.32-358.el6.x86_64 (x86_64), Display Driver: vmware 12.0.2, Compiler: GCC 4.4.7 20120313, File-System: ext4, System Layer: VMware
2013-06-24 23:43:
Processor: 2 x Intel Xeon E5-2470 0 @ 2.29GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 16384 MB DRAM, Disk: 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS 6.4, Kernel: 2.6.32-358.el6.x86_64 (x86_64), Display Driver: vmware 12.0.2, Compiler: GCC 4.4.7 20120313, File-System: ext4, System Layer: VMware
2013-06-26 09:20:
Processor: 2 x Intel Xeon E5-2470 0 @ 2.29GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 16384 MB DRAM, Disk: 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS 6.4, Kernel: 2.6.32-358.el6.x86_64 (x86_64), Display Driver: vmware 12.0.2, Compiler: GCC 4.4.7 20120313, File-System: ext4, System Layer: VMware
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 39.31 |=========================================================
RAMspeed SMP 3.5.0
Type: Copy - Benchmark: Integer
MB/s > Higher Is Better
16384 MB DRAM . 16751.14 |=====================================================
16384 MB DRAM . 16772.97 |=====================================================
16384 MB DRAM . 16807.38 |=====================================================
16384 MB DRAM . 16759.48 |=====================================================
16384 MB DRAM . 16809.78 |=====================================================
16384 MB DRAM . 16545.78 |====================================================
RAMspeed SMP 3.5.0
Type: Add - Benchmark: Integer
MB/s > Higher Is Better
16384 MB DRAM . 16635.34 |=====================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 39.05 |=========================================================
RAMspeed SMP 3.5.0
Type: Scale - Benchmark: Integer
MB/s > Higher Is Better
16384 MB DRAM . 16696.03 |=====================================================
RAMspeed SMP 3.5.0
Type: Triad - Benchmark: Integer
MB/s > Higher Is Better
16384 MB DRAM . 16792.16 |=====================================================
RAMspeed SMP 3.5.0
Type: Average - Benchmark: Integer
MB/s > Higher Is Better
16384 MB DRAM . 16784.91 |=====================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 40.72 |=========================================================
RAMspeed SMP 3.5.0
Type: Add - Benchmark: Floating Point
MB/s > Higher Is Better
16384 MB DRAM . 17504.93 |=====================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 40.44 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 41.70 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 41.15 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 7186.18 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 7258.20 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 42.27 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 42.35 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 5717.13 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 7421.51 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 5602.51 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 7188.80 |=======================================================
RAMspeed SMP 3.5.0
Type: Copy - Benchmark: Floating Point
MB/s > Higher Is Better
16384 MB DRAM . 13567.53 |=====================================================
RAMspeed SMP 3.5.0
Type: Scale - Benchmark: Floating Point
MB/s > Higher Is Better
16384 MB DRAM . 13514.58 |=====================================================
RAMspeed SMP 3.5.0
Type: Triad - Benchmark: Floating Point
MB/s > Higher Is Better
16384 MB DRAM . 17439.13 |=====================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 38.89 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 5773.20 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 41.29 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 7359.16 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 41.58 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 5754.39 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 7119.43 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 7359.29 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 7245.48 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 7046.06 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 41.68 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 7186.76 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 42.13 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 7173.88 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 40.63 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 7282.30 |=======================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 40.09 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 4265.41 |=======================================================
RAMspeed SMP 3.5.0
Type: Average - Benchmark: Floating Point
MB/s > Higher Is Better
16384 MB DRAM . 15464.53 |=====================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 41.10 |=========================================================
FS-Mark 3.3
Test: 1000 Files, 1MB Size
Files/s > Higher Is Better
Virtual disk . 15.93 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 5755.27 |=======================================================
FS-Mark 3.3
Test: 5000 Files, 1MB Size, 4 Threads
Files/s > Higher Is Better
Virtual disk . 25.20 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 2.62 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 0.94 |==========================================================
FS-Mark 3.3
Test: 1000 Files, 1MB Size, No Sync/FSync
Files/s > Higher Is Better
Virtual disk . 1033.98 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 2.29 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 1.46 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 6149.84 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 3.89 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 5758.07 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1.65 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 4759.76 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 4046.65 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 4113.07 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 5488.62 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 4199.26 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 5783.35 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1.04 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 6015.96 |=======================================================
FS-Mark 3.3
Test: 4000 Files, 32 Sub Dirs, 1MB Size
Files/s > Higher Is Better
Virtual disk . 14.73 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 5912.34 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 6346.31 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1.49 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 5400.77 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1.11 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 6205.29 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 3.22 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 4.81 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 1.94 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 4.32 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 1.13 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 2.71 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 0.86 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 6157.83 |=======================================================
Apache Benchmark 2.4.3
Static Web Page Serving
Requests Per Second > Higher Is Better
2013-06-26 09:20 . 13113.87 |==================================================
PHPBench 0.8.1
PHP Benchmark Suite
Score > Higher Is Better
2013-06-24 23:43 . 67991 |=====================================================
BYTE Unix Benchmark 3.6
Computational Test: Dhrystone 2
LPS > Higher Is Better
Intel Xeon E5-2470 0 . 19505387.03 |===========================================
BYTE Unix Benchmark 3.6
Computational Test: Integer Arithmetic
LPS > Higher Is Better
Intel Xeon E5-2470 0 . 1939109.07 |============================================
BYTE Unix Benchmark 3.6
Computational Test: Register Arithmetic
LPS > Higher Is Better
Intel Xeon E5-2470 0 . 1944130.33 |============================================
BYTE Unix Benchmark 3.6
Computational Test: Floating-Point Arithmetic
LPS > Higher Is Better
Intel Xeon E5-2470 0 . 1918973.30 |============================================