TrueNAS HDD Intel Xeon E3-1230 v6 testing on FreeBSD via the Phoronix Test Suite. truenas default hdd test: Processor: Intel Xeon E3-1230 v6 @ 3.50GHz (8 Cores), Motherboard: Supermicro Super Server 0123456789, Memory: 32GB, Disk: Generic NVMe Device OS: FreeBSD, Kernel: 13.1-RELEASE-p7 (x86_64), Compiler: Clang 14.0.5, File-System: zfs truenas nvme test: Processor: Intel Xeon E3-1230 v6 @ 3.50GHz (8 Cores), Motherboard: Supermicro Super Server 0123456789, Memory: 32GB, Disk: Generic NVMe Device OS: FreeBSD, Kernel: 13.1-RELEASE-p7 (x86_64), Compiler: Clang 14.0.5, File-System: zfs truenas nvme: Processor: Intel Xeon E3-1230 v6 @ 3.50GHz (8 Cores), Motherboard: Supermicro Super Server 0123456789, Memory: 32GB, Disk: Generic NVMe Device OS: FreeBSD, Kernel: 13.1-RELEASE-p7 (x86_64), Compiler: Clang 14.0.5, File-System: zfs Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6472 |============================================== truenas nvme ............. 6509 |============================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6457 |============================================== truenas nvme ............. 6480 |============================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 568 |============================================= truenas nvme ............. 587 |=============================================== truenas nvme ............. 586 |=============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 145333 |=========================================== truenas nvme ............. 149667 |============================================ Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6443 |============================================== truenas nvme ............. 6465 |============================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1131 |============================================= truenas nvme ............. 1167 |============================================== truenas nvme ............. 1166 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 145000 |=========================================== truenas nvme ............. 149000 |============================================ Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 2175 |============================================= truenas nvme ............. 2241 |============================================== truenas nvme ............. 2235 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 139333 |=========================================== truenas nvme ............. 143000 |============================================ Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 3765 |============================================= truenas nvme ............. 3868 |============================================== truenas nvme ............. 3890 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 120333 |========================================== truenas nvme ............. 124667 |============================================ Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 5421 |============================================= truenas nvme ............. 5515 |============================================== truenas nvme ............. 5501 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 86733 |============================================ truenas nvme ............. 88000 |============================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7850 |============================================== truenas nvme ............. 7365 |=========================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7829 |============================================== truenas nvme ............. 7274 |=========================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1099 |============================================== truenas nvme ............. 1081 |============================================= truenas nvme ............. 1077 |============================================= Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 281333 |============================================ truenas nvme ............. 275667 |=========================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7810 |============================================== truenas nvme ............. 7272 |=========================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1175 |========================= truenas nvme ............. 2152 |============================================== truenas nvme ............. 2140 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 150333 |======================== truenas nvme ............. 273667 |============================================ Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7002 |=========================================== truenas nvme ............. 7424 |============================================== truenas nvme ............. 7432 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 56000 |========================================== truenas nvme ............. 59467 |============================================= Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6975 |========================================== truenas nvme ............. 7573 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 27900 |========================================= truenas nvme ............. 30300 |============================================= Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6740 |========================================== truenas nvme ............. 7444 |============================================== truenas nvme ............. 7442 |============================================== Flexible IO Tester Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 13500 |========================================= truenas nvme ............. 14900 |============================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1210 |============== truenas nvme ............. 4061 |============================================== truenas nvme ............. 4077 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 77420 |============= truenas nvme ............. 261000 |============================================ Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6762 |============================================= truenas nvme ............. 6906 |============================================== truenas nvme ............. 6835 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 216667 |============================================ truenas nvme ............. 219000 |============================================ Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 8053 |============================================== truenas nvme ............. 7753 |============================================ truenas nvme ............. 7940 |============================================= Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 129000 |============================================ truenas nvme ............. 127133 |=========================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7965 |============================================= truenas nvme ............. 7838 |============================================= truenas nvme ............. 8062 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 63700 |============================================ truenas nvme ............. 64467 |============================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7992 |============================================== truenas nvme ............. 7913 |============================================== truenas nvme ............. 7934 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 31967 |============================================= truenas nvme ............. 31727 |============================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7916 |============================================== truenas nvme ............. 7596 |============================================ truenas nvme ............. 7878 |============================================== Flexible IO Tester Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 15833 |============================================= truenas nvme ............. 15753 |============================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6163 |============================================== truenas nvme ............. 6172 |============================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6135 |============================================== truenas nvme ............. 6140 |============================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1413 |============================================== truenas nvme ............. 1421 |============================================== truenas nvme ............. 1418 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 361667 |============================================ truenas nvme ............. 363000 |============================================ Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 6105 |============================================== truenas nvme ............. 6109 |============================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 2596 |============================================== truenas nvme ............. 2616 |============================================== truenas nvme ............. 2622 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 332333 |============================================ truenas nvme ............. 335667 |============================================ Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 4898 |============================================== truenas nvme ............. 4925 |============================================== truenas nvme ............. 4937 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 313333 |============================================ truenas nvme ............. 316000 |============================================ Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7476 |============================================= truenas nvme ............. 7516 |============================================== truenas nvme ............. 7576 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 239333 |=========================================== truenas nvme ............. 242333 |============================================ Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7321 |============================================== truenas nvme ............. 7346 |============================================== truenas nvme ............. 7340 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 117000 |============================================ truenas nvme ............. 117667 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7907 |============================================== truenas nvme ............. 7522 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7866 |============================================== truenas nvme ............. 7432 |=========================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1074 |====================================== truenas nvme ............. 1264 |============================================= truenas nvme ............. 1289 |============================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 275000 |===================================== truenas nvme ............. 330000 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7842 |============================================== truenas nvme ............. 7245 |========================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1225 |======================== truenas nvme ............. 2316 |============================================== truenas nvme ............. 2306 |============================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 156667 |======================= truenas nvme ............. 295333 |============================================ Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7083 |============================================== truenas nvme ............. 7100 |============================================== truenas nvme ............. 7097 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 56667 |============================================= truenas nvme ............. 56767 |============================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7211 |============================================== truenas nvme ............. 7229 |============================================== truenas nvme ............. 7226 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 28867 |============================================= truenas nvme ............. 28900 |============================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7052 |============================================== truenas nvme ............. 7052 |============================================== truenas nvme ............. 7059 |============================================== Flexible IO Tester Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 14100 |============================================= truenas nvme ............. 14100 |============================================= Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 1227 |============= truenas nvme ............. 4422 |============================================== truenas nvme ............. 4464 |============================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 78517 |============ truenas nvme ............. 285667 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7166 |========================================== truenas nvme ............. 7796 |============================================= truenas nvme ............. 7914 |============================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 229333 |======================================== truenas nvme ............. 253000 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 8083 |============================================= truenas nvme ............. 7865 |=========================================== truenas nvme ............. 8321 |============================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 129333 |=========================================== truenas nvme ............. 133000 |============================================ Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7967 |============================================== truenas nvme ............. 7653 |============================================ truenas nvme ............. 7562 |============================================ Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 63733 |============================================= truenas nvme ............. 60500 |=========================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7988 |============================================== truenas nvme ............. 7576 |============================================ truenas nvme ............. 7463 |=========================================== Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 31967 |============================================= truenas nvme ............. 29833 |========================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better truenas default hdd test . 7961 |============================================== truenas nvme ............. 7416 |=========================================== truenas nvme ............. 7588 |============================================ Flexible IO Tester Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas default hdd test . 15933 |============================================= truenas nvme ............. 15186 |=========================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 150667 |======================================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 149000 |======================================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 143667 |======================================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 124000 |======================================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 88233 |========================================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 276667 |======================================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 275667 |======================================================== Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 59400 |========================================================= Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 30267 |========================================================= Flexible IO Tester 3.35 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 14900 |========================================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 259667 |======================================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 220667 |======================================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 124333 |======================================================== Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 62700 |========================================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 31653 |========================================================= Flexible IO Tester 3.35 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 15180 |========================================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 363667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 334667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 315333 |======================================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 240667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 117667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 323333 |======================================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 296667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 56800 |========================================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 28900 |========================================================= Flexible IO Tester 3.35 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 14100 |========================================================= Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 283000 |======================================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 249667 |======================================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 126000 |======================================================== Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 61225 |========================================================= Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 30300 |========================================================= Flexible IO Tester 3.35 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better truenas nvme . 14833 |=========================================================