2 x AMD EPYC 7513 32-Core testing with a Dell PowerEdge R7525 [0590KW] (2.6.6 BIOS) and Matrox G200eW3 on Debian GNU/Linux 11 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 2210041-NE-2209208NE88
45drivesxl60,
"Flexible IO Tester 3.25 - Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",8929,9324,9141
"DELL ENT NVME SSD1",202,204,204
"DELL SAMSUNG SSD4",2078,2082,2081
"DELL ENTERPRISE NVME",2284,2286,2286
"SAMSUNG ZFS MIRROR",6288,6294,6010,5943,6102,5919,6148,6264,6316,6164
"DELLENT ZFS MIRROR",6114,5120,6235,6137,6184,6296,5966,6152,6120,5994,6232,6349,6058
"PERC RAID1 SAMSUNG 256-A-D-C",2799,2805,2800
"PERC RAID1 DELL ENT. H755",2492,2493,2678,2403,2454,2523,2502,2357,2462,2445,2472,2477,2455,2444,2461
"NFS 1 NO SSD",192,194,195
"Flexible IO Tester 3.25 - Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",92900,91500,92500
"5 Per VDEV RaidZ2",110000,112000,109000
"Mirrors",132000,127000,129000
"DELL ENT NVME SSD1",18800,17600,18800,15800,17600,18800,18700,18700,18900,17600,17600,18700,18700,18800,18800
"DELL SAMSUNG SSD4",6241,6246,6240
"DELL ENTERPRISE NVME",61100,61300,61300
"SAMSUNG ZFS MIRROR",
"DELLENT ZFS MIRROR",182000,186000,187000
"PERC RAID1 SAMSUNG 256-A-D-C",36100,33000,33300,33200,32300,32400,31000,32300,32200,32200,32200,32400,32300,32400,32200
"PERC RAID1 DELL ENT. H755",46300,45300,43700,37800,43700,33300,44100,44300,44300,44200,44200,44100
"NFS 1 NO SSD",2226,2194,2225
"Flexible IO Tester 3.25 - Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",363,357,361
"5 Per VDEV RaidZ2",431,436,428
"Mirrors",516,497,503
"DELL ENT NVME SSD1",73.3,68.7,73.3,61.8,68.7,73.5,72.9,72.9,73.8,68.7,68.9,73.2,73.1,73.3,73.4
"DELL SAMSUNG SSD4",24.4,24.4,24.4
"DELL ENTERPRISE NVME",239,240,240
"SAMSUNG ZFS MIRROR",702,702,704
"DELLENT ZFS MIRROR",709,726,729
"PERC RAID1 SAMSUNG 256-A-D-C",141,133,130,130,126,127,125,126,126,126,126,127,126,127,126
"PERC RAID1 DELL ENT. H755",181,177,171,148,171,130,172,173,173,173,173,172
"NFS 1 NO SSD",8.918,8.793,8.913
"Flexible IO Tester 3.25 - Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",
"5 Per VDEV RaidZ2",135000,136000,136000
"Mirrors",138000,138000,137000
"DELL ENT NVME SSD1",18000,16200,17900,18900,17900,17900,19000,17900,17000,17900,17900,18000,17800,17900
"DELL SAMSUNG SSD4",6383,6387,6384
"DELL ENTERPRISE NVME",61600,61500,61400
"SAMSUNG ZFS MIRROR",331000,325000,343000,324000,374000,366000,372000,366000,359000,369000,368000,350000
"DELLENT ZFS MIRROR",338000,303000,336000,329000,334000,322000,329000,335000,335000,336000,355000,336000,352000,332000,328000
"PERC RAID1 SAMSUNG 256-A-D-C",40200,40100,39000
"PERC RAID1 DELL ENT. H755",48300,48400,47800
"NFS 1 NO SSD",2323,2306,2327
"Flexible IO Tester 3.25 - Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",
"5 Per VDEV RaidZ2",
"Mirrors",539,538,535
"DELL ENT NVME SSD1",74.2,63.3,69.8,74,69.8,69.8,74.3,69.8,70.2,69.9,69.8,70.4,69.6,69.8
"DELL SAMSUNG SSD4",24.9,24,24
"DELL ENTERPRISE NVME",
"SAMSUNG ZFS MIRROR",1295,1268,1341,1265,1461,1430,1452,1431,1400,1441,1437,1368
"DELLENT ZFS MIRROR",1320,1185,1312,1287,1304,1256,1285,1308,1309,1313,1386,1314,1375,1296,1280
"PERC RAID1 SAMSUNG 256-A-D-C",
"PERC RAID1 DELL ENT. H755",189,189,187
"NFS 1 NO SSD",9.305,9.239,9.324
"Flexible IO Tester 3.25 - Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",71400,74600,73100
"5 Per VDEV RaidZ2",92700,90400,90800
"Mirrors",99300,102000,98400
"DELL ENT NVME SSD1",1613,1627,1628
"DELL SAMSUNG SSD4",16600,16700,16600
"DELL ENTERPRISE NVME",
"SAMSUNG ZFS MIRROR",50300,50300,48100,47500,48800,47300,49200,50100,50500,49300
"DELLENT ZFS MIRROR",48900,40000,49900,49100,49500,50400,47700,49200,48000,47900,49900,50800,48500
"PERC RAID1 SAMSUNG 256-A-D-C",
"PERC RAID1 DELL ENT. H755",19900,19900,21400,19200,19600,20200,20000,18900,19700,19600,19800,19800,19600,19500,19700
"NFS 1 NO SSD",1530,1547,1554
"Flexible IO Tester 3.25 - Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",135000,153000,146000,133000,134000,134000,138000,155000,154000,155000,153000,153000,153000,154000,154000
"5 Per VDEV RaidZ2",132000,131000,131000
"Mirrors",127000,134000,134000,134000,134000
"DELL ENT NVME SSD1",1559,1545,1554
"DELL SAMSUNG SSD4",17100,17200,17100
"DELL ENTERPRISE NVME",9461,9461,9448
"SAMSUNG ZFS MIRROR",53200,55600,54500
"DELLENT ZFS MIRROR",47000,50200,51700,54400,52300,52500,54300,53000,52900,54900,54100,53700,53800,53900,54000
"PERC RAID1 SAMSUNG 256-A-D-C",22000,22100,21000
"PERC RAID1 DELL ENT. H755",13000,13200,13300
"NFS 1 NO SSD",2177,2133,2188
"Flexible IO Tester 3.25 - Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",187000,189000,188000
"5 Per VDEV RaidZ2",189000,188000,187000
"Mirrors",190000,189000,189000
"DELL ENT NVME SSD1",7205,7165,7179
"DELL SAMSUNG SSD4",63100,63000,63100
"DELL ENTERPRISE NVME",
"SAMSUNG ZFS MIRROR",533000,467000,430000,462000,401000,430000,453000,444000,511000,402000,387000,414000,393000,416000,459000
"DELLENT ZFS MIRROR",524000,434000,416000,387000,427000,443000,438000,433000,431000,424000,412000,460000,441000,445000,402000
"PERC RAID1 SAMSUNG 256-A-D-C",34300,34400,34400
"PERC RAID1 DELL ENT. H755",51900,52200,52200
"NFS 1 NO SSD",2486,2487,2490
"Flexible IO Tester 3.25 - Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",732,738,734
"5 Per VDEV RaidZ2",738,734,732
"Mirrors",742,737,737
"DELL ENT NVME SSD1",28.2,28,28.1
"DELL SAMSUNG SSD4",247,246,246
"DELL ENTERPRISE NVME",87,88,87.9
"SAMSUNG ZFS MIRROR",2081,1824,1680,1804,1565,1678,1771,1735,1996,1571,1514,1618,1535,1626,1795
"DELLENT ZFS MIRROR",2045,1696,1624,1513,1670,1730,1710,1693,1684,1657,1610,1799,1722,1739,1572
"PERC RAID1 SAMSUNG 256-A-D-C",
"PERC RAID1 DELL ENT. H755",203,204,204
"NFS 1 NO SSD",9.96,9.964,9.976
"Flexible IO Tester 3.25 - Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",679,689,687
"5 Per VDEV RaidZ2",687,695,695
"Mirrors",695,703,694
"DELL ENT NVME SSD1",27.4,27.2,27.3
"DELL SAMSUNG SSD4",38.4,38.4,38.4
"DELL ENTERPRISE NVME",47.2,47.2,47.2
"SAMSUNG ZFS MIRROR",385,389,389
"DELLENT ZFS MIRROR",351,332,311,383,394,417,412,435,415,407,419,350
"PERC RAID1 SAMSUNG 256-A-D-C",65.1,113,114,114,114,120,48.9,48.1,49.3,48.6,48.7,87,80.2,82.4,74.1
"PERC RAID1 DELL ENT. H755",
"NFS 1 NO SSD",9.852,9.895,9.964
"Flexible IO Tester 3.25 - Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",174000,176000,176000
"5 Per VDEV RaidZ2",176000,178000,178000
"Mirrors",178000,180000,178000
"Mirrors",177000,179000,179000
"DELL ENT NVME SSD1",7019,6971,6984
"DELL SAMSUNG SSD4",9833,9817,9826
"DELL ENTERPRISE NVME",
"SAMSUNG ZFS MIRROR",98400,99500,99500
"DELLENT ZFS MIRROR",89900,84900,79600,98000,101000,107000,105000,111000,106000,104000,107000,89600
"PERC RAID1 SAMSUNG 256-A-D-C",16700,29000,29100,29200,29100,30700,12500,12300,12600,12400,12500,22300,20500,21100,18000
"PERC RAID1 DELL ENT. H755",
"NFS 1 NO SSD",2459,2470,2487
"Flexible IO Tester 3.25 - Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"DELL ENT NVME SSD1",
"DELL SAMSUNG SSD4",2133,2146,2134
"DELL ENTERPRISE NVME",1183,1183,1181
"SAMSUNG ZFS MIRROR",6646,6952,6815
"DELLENT ZFS MIRROR",5995,6280,6458,6799,6544,6563,6788,6744,6613,6859,6758,6718,6723,6738,6752
"PERC RAID1 SAMSUNG 256-A-D-C",2751,2767,2744
"PERC RAID1 DELL ENT. H755",1631,1648,1657
"NFS 1 NO SSD",273,267,274
"Flexible IO Tester 3.25 - Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",157000,157000,156000
"5 Per VDEV RaidZ2",158000,156000,157000
"Mirrors",156000,157000,156000
"DELL ENT NVME SSD1",1556,1566,1561
"DELL SAMSUNG SSD4",6384,6241,6356
"DELL ENTERPRISE NVME",7627,7640,7632
"SAMSUNG ZFS MIRROR",57900,59900,58400
"DELLENT ZFS MIRROR",57300,58400,56400
"PERC RAID1 SAMSUNG 256-A-D-C",9579,9595,9666
"PERC RAID1 DELL ENT. H755",12800,12700,12800
"NFS 1 NO SSD",2199,2115,2102
"Flexible IO Tester 3.25 - Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"DELL ENT NVME SSD1",195,196,196
"DELL SAMSUNG SSD4",798,781,795
"DELL ENTERPRISE NVME",954,955,955
"SAMSUNG ZFS MIRROR",7234,7484,7301
"DELLENT ZFS MIRROR",7164,7296,7055
"PERC RAID1 SAMSUNG 256-A-D-C",1198,1200,1209
"PERC RAID1 DELL ENT. H755",1595,1585,1594
"NFS 1 NO SSD",275,265,263
"Flexible IO Tester 3.25 - Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",72100,74400,71600
"5 Per VDEV RaidZ2",94700,92100,93700
"Mirrors",96300,96200,94700
"DELL ENT NVME SSD1",1598,1634,1618
"DELL SAMSUNG SSD4",
"DELL ENTERPRISE NVME",
"SAMSUNG ZFS MIRROR",49800,49400,49700
"DELLENT ZFS MIRROR",51900,50700,52300
"PERC RAID1 SAMSUNG 256-A-D-C",
"PERC RAID1 DELL ENT. H755",18600,18700,18800
"NFS 1 NO SSD",1538,1531,1534
"Flexible IO Tester 3.25 - Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory",
Higher Results Are Better
"10 Per VDEV RaidZ2",9008,9297,8944
"DELL ENT NVME SSD1",200,205,203
"DELL SAMSUNG SSD4",
"DELL ENTERPRISE NVME",2284,2289,2285
"SAMSUNG ZFS MIRROR",6232,6181,6218
"DELLENT ZFS MIRROR",6484,6341,6536
"PERC RAID1 SAMSUNG 256-A-D-C",2801,2797,2797
"PERC RAID1 DELL ENT. H755",2324,2333,2346
"NFS 1 NO SSD",193,192,192