Synology_RS3621XS_Plus 12x Nytro 3332 Raid10 SA3200D 32 Core Epyc 128Gb XCP-NG VM on 10G dedicated network Raid F1: Processor: Intel Xeon D-1541 (12 Cores), Motherboard: QEMU Standard PC (i440FX + PIIX 1996) (Virtualization-2.5.1-9619-200306-0-gb56c451 BIOS), Chipset: Intel 440FX 82441FX PMC, Memory: 4096MB, Disk: 107GB iSCSI Storage, Graphics: VMware SVGA II, Network: Red Hat Virtio device OS: Ubuntu 20.04, Kernel: 5.4.0-89-generic (x86_64), Vulkan: 1.0.2, Compiler: GCC 9.3.0, File-System: ext4, System Layer: microsoft VMware SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 SA3200D Docker Local: Processor: Intel Xeon D-1521 @ 2.40GHz (4 Cores / 8 Threads), Motherboard: Type2 Board Vendor Name1 Product (M.F01 BIOS), Memory: 16GB, Disk: 20577GB OS: Ubuntu 20.04.1 LTS, Kernel: 4.4.59+ (x86_64), Compiler: GCC 9.3.0, File-System: btrfs, System Layer: Docker Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1054 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 631 |================ SA3200D Docker Local ......................... 837 |===================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1050 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 628 |================ SA3200D Docker Local ......................... 834 |===================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 7.506 |========= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 18.900 |===================== SA3200D Docker Local ......................... 21.100 |======================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1873 |========= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4843 |======================= SA3200D Docker Local ......................... 5476 |========================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 79.0 |=========== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 174.0 |========================= SA3200D Docker Local ......................... 130.0 |=================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1262 |============ SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2775 |========================== SA3200D Docker Local ......................... 2082 |==================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1767 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 543 |======== SA3200D Docker Local ......................... 1060 |================ Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1763 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 540 |======== SA3200D Docker Local ......................... 1057 |================ Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 104.0 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 17.4 |==== SA3200D Docker Local ......................... 78.5 |=================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 26733 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4553 |==== SA3200D Docker Local ......................... 20100 |=================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 751 |=========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 172 |====== SA3200D Docker Local ......................... 416 |=============== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 12033 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2756 |====== SA3200D Docker Local ......................... 6658 |============== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1065 |=============== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 647 |========= SA3200D Docker Local ......................... 1848 |========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1061 |=============== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 644 |========= SA3200D Docker Local ......................... 1845 |========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 9.94 |========= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 19.40 |================= SA3200D Docker Local ......................... 28.20 |========================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 2541 |========= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4975 |================== SA3200D Docker Local ......................... 7209 |========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 116 |===== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 178 |======= SA3200D Docker Local ......................... 668 |=========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1857 |==== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2847 |======= SA3200D Docker Local ......................... 10667 |========================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 2122 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 597 |======= SA3200D Docker Local ......................... 1057 |============= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 2118 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 593 |======= SA3200D Docker Local ......................... 1053 |============= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 125.0 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 18.9 |==== SA3200D Docker Local ......................... 88.4 |================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 31833 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4824 |==== SA3200D Docker Local ......................... 22633 |================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1107 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 173 |==== SA3200D Docker Local ......................... 422 |========== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 17700 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2763 |==== SA3200D Docker Local ......................... 6743 |==========