Synology_RS3621XS_Plus 12x Nytro 3332 Raid10 SA3200D 32 Core Epyc 128Gb XCP-NG VM on 10G dedicated network Raid F1: Processor: Intel Xeon D-1541 (12 Cores), Motherboard: QEMU Standard PC (i440FX + PIIX 1996) (Virtualization-2.5.1-9619-200306-0-gb56c451 BIOS), Chipset: Intel 440FX 82441FX PMC, Memory: 4096MB, Disk: 107GB iSCSI Storage, Graphics: VMware SVGA II, Network: Red Hat Virtio device OS: Ubuntu 20.04, Kernel: 5.4.0-89-generic (x86_64), Vulkan: 1.0.2, Compiler: GCC 9.3.0, File-System: ext4, System Layer: microsoft VMware SA3200D 12x nytro raid 5: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 SA3200 6x Nytro Raid 10: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 SA3200D 6x Nytro F1: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 jumbo: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 jumbo frames: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 direct: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 Raid10 12 drives: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM: Processor: AMD EPYC 7502 32-Core (32 Cores), Motherboard: Xen HVM domU v4.13, Chipset: Intel 440FX 82441FX PMC, Memory: 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16 GB + 16376 MB RAM, Disk: 15GB, Graphics: bochs-drmdrmfb OS: Debian 11, Kernel: 5.10.0-9-amd64 (x86_64), Vulkan: 1.0.2, Compiler: GCC 10.2.1 20210110, File-System: ext4, Screen Resolution: 1024x768, System Layer: Xen HVM domU 4.13 Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1061 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 644 |================ Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1065 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 647 |================ Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1262 |=========== SA3200D 6x Nytro F1 .......................... 2877 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2775 |========================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 79.0 |=========== SA3200D 6x Nytro F1 .......................... 180.0 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 174.0 |======================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1857 |================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2847 |========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 116 |================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 178 |=========================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1873 |========== SA3200D 6x Nytro F1 .......................... 4844 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4843 |========================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 7.506 |========= SA3200D 6x Nytro F1 .......................... 19.000 |======================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 18.900 |======================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1050 |========================== SA3200D 12x nytro raid 5 ..................... 564 |============== SA3200 6x Nytro Raid 10 ...................... 566 |============== SA3200D 6x Nytro F1 .......................... 586 |=============== jumbo ........................................ 582 |============== jumbo frames ................................. 627 |================ direct ....................................... 644 |================ Raid10 12 drives ............................. 639 |================ SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 628 |================ Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1054 |========================== SA3200D 12x nytro raid 5 ..................... 568 |============== SA3200 6x Nytro Raid 10 ...................... 569 |============== SA3200D 6x Nytro F1 .......................... 590 |=============== jumbo ........................................ 586 |============== jumbo frames ................................. 631 |================ direct ....................................... 648 |================ Raid10 12 drives ............................. 643 |================ SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 631 |================ Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 31833 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4824 |==== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 125.0 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 18.9 |==== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 26733 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4553 |==== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 104.0 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 17.4 |==== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 2541 |============= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 4975 |========================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 9.94 |============= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 19.40 |========================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 1763 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 540 |======== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1767 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 543 |======== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 2118 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 593 |======= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 2122 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 597 |======= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 12033 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2756 |====== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 751 |=========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 172 |====== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Raid F1 ...................................... 17700 |========================= SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 2763 |==== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Raid F1 ...................................... 1107 |========================== SA3200D 12x Nytro 3332 Raid 10 via XCP-NG VM . 173 |====