bmark4 KVM testing on NixOS 21.05 via the Phoronix Test Suite. CEPH vs local lvm FIO comparison: Processor: AMD EPYC 7763 64-Core (126 Cores), Motherboard: QEMU Standard PC (i440FX + PIIX 1996) (rel-1.14.0-0-g155821a1990b-prebuilt.qemu.org BIOS), Chipset: Intel 440FX 82441FX PMC, Memory: 378GB, Disk: 34GB QEMU HDD, Graphics: bochs-drmdrmfb, Monitor: QEMU Monitor, Network: Red Hat Virtio device OS: NixOS 21.05, Kernel: 5.10.66 (x86_64), Compiler: GCC 10.3.0, File-System: tmpfs, Screen Resolution: 1024x768, System Layer: KVM Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3843 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3382 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3003 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2549 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2330 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4028 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3590 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3827 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3421 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.936 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1484 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1369 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3983 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3549 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3062 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2551 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2197 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3067 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2508 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 133 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2125 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3974 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3537 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1234 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.1 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1187 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1028 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.777 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1444 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1355 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 414 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106160 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 478 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61120 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3141 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2677 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3814 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 150 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2403 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3558 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4157 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3705 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3940 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3582 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2997 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2583 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2298 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.192 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1548 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 11.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1437 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1305 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1193 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 66.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1059 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 528 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33767 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 569 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18213 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9346 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 418 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 107107 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 511 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 65400 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 419 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 107200 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 760 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97267 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3159 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2667 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3831 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5745 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 153 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2444 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3690 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5539 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3055 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2584 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3930 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2186 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3559 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3135 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2597 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3847 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2140 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3620 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3952 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3511 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1253 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1240 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 63.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1030 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 118 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15067 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.103 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1525 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 11.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1446 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 486 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 124400 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 535 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 68433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 546 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34960 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 568 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18187 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 589 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9418 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4311 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3798 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1312 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83980 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 2230 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71333 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 2460 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 422 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 746 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 95567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 391 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99767 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 661 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 84567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 417 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106333 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 732 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 93700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3825 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3543 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3300 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5168 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 84.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2706 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4609 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2376 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3814 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3094 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2479 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4041 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5843 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2199 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3583 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5573 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3104 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2479 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3881 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5693 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 127 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2030 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3511 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5487 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3098 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2606 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3889 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2330 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3596 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 63.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16140 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 109 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13947 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 223 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14253 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 417 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13287 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.587 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1396 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13167 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 676 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10813 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.27 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1317 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 99.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12733 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1305 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.8 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1242 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 63.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16233 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 66.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1066 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 120 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 617 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20633 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 612 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156733 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 647 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10278 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 635 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81229 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 461 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 117867 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 520 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 66567 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3157 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2445 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 130 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2084 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4257 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3819 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 487 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 124667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 505 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 64700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.634 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1658 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1562 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 382 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97647 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 689 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 88133 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1308 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1396 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44580 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1321 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21127 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1099 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70333 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1297 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41500 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1207 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19325 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 374 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 95367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 644 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82100 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1289 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82475 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1425 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1362 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21767 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 390 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 721 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 92267 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3754 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3422 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2996 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2438 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 131 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2090 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3845 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3389 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3742 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3399 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5846 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5610 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3194 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4941 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 82.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2644 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4214 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2266 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 208 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3331 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3192 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 75.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4843 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2614 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 125 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4001 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2186 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 197 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3157 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3037 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2672 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3983 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5702 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 148 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2361 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3421 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5460 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 206 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13150 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 441 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13967 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 833 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16500 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 117 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14993 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 414 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 105913 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 459 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 58640 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.9 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 116 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14875 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.909 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1473 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1364 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1250 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 177 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 36.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1182 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 298 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9532 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1028 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 455 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7277 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 221 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 435 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13867 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.807 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1451 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 686 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10967 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.23 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1307 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 100.3 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 674 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43067 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 704 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 454 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 116333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 718 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11480 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 524 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 67060 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 621 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39640 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20527 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 152000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 678 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10773 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 643 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82207 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4248 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 32.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4179 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3259 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2504 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 133 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2120 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 501 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32067 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 511 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 450 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7206 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 497 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 127000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 489 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 62567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1408 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 39.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1249 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 69.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1117 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.974 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1743 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1659 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 526 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 134800 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 590 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1165 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1223 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39067 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 379 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97053 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1106 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17525 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 755 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 96367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 385 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 98600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 714 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 91363 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 361 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 92367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 636 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1113 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71233 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1088 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34800 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 973 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 378 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 96733 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 741 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 94880 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1313 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 84033 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1201 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38433 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1026 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16400 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2968 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2479 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2191 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3649 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3324 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3750 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3400 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2969 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2589 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 143 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2292 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3005 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2529 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 135 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2159 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3719 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3321 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5170 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4659 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 243 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3896 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5780 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5530 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5641 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5331 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3119 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5012 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2542 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4294 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2326 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 221 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3539 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 115 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14400 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 226 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 469 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15020 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 830 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13080 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 482 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 522 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16667 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 521 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8339 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 403 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 103213 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 454 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 58047 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 215 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13400 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 445 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14233 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 791 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12580 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 60.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15486 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 108 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13673 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 396 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 101162 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 444 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 56693 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1233 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.1 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1121 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 975 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.894 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1470 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1370 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 399 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 102093 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 463 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59208 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 36.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9406 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 75.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9631 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1238 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 184 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1141 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 306 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9793 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 982 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 459 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7345 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 586 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44367 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 630 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 712 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22767 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 633 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 722 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 697 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 451 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 115287 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 613 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 157000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 663 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10612 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 543 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69553 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 653 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82967 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3161 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2575 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4150 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2150 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3882 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4303 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3807 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 483 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 123667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 482 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 517 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33100 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 548 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 480 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7687 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.890 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1722 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1590 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1377 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 36.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1175 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 67.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1086 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 559 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35617 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 546 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17340 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 541 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8652 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 545 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 139333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 538 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 68850 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1148 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1467 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46933 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61020 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 664 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 170000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1348 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21550 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 476 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1149 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1691 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 54133 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 391 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 100067 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1907 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 716 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 91680 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 961 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1442 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45833 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 346 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 88567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1659 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 26567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 650 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83217 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 352 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 89893 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 661 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 84567 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1179 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1720 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 55033 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 380 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97200 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1934 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 717 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 91775 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 377 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 96200 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 684 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 87533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3837 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3441 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2960 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2520 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2207 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2968 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 73.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2361 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3817 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 123 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1968 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3376 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3743 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3512 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3773 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3418 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2967 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2525 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 139 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2211 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4902 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 130 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4182 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 212 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3390 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 75.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4832 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 127 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4073 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 198 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3177 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 23.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5885 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5594 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 196 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 431 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13767 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 67.8 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17367 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 703 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11105 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 127 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16113 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 59.0 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 106 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13540 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 468 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 119733 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 530 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 67867 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 470 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29947 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 492 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15633 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 497 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7950 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 56.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 104 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13367 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 207 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13207 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 420 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13373 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 722 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11487 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 499 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31933 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 536 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8776 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 380 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 440 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 56207 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.692 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1420 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 11.1 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1419 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.0 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1275 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1135 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 982 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 507 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32293 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 531 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16913 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 543 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8690 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 385 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 98427 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 465 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 131 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8366 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 234 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7473 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 377 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6030 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9530 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 69.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8888 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 160333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 651 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39325 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 691 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 616 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 713 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 631 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10080 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 749 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12000 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10167 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3242 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2539 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4262 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7675 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 135 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2152 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3914 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 56.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7186 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3253 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2575 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4209 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2196 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3841 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 488 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 495 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 500 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 128000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 432 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6904 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 494 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 63200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 496 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 127000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 484 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61867 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1366 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1228 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 67.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1084 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 162 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20593 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.665 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1666 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 13.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1682 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 592 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 151667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 622 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 79533 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 603 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38507 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 607 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19273 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 604 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9663 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 866 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 55433 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1630 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52167 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1971 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1207 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 77260 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1713 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 54688 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61167 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 665 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 170333 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1754 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 28067 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 474 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 64267 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1437 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 204 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52133 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 647 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 165333 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1514 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23900 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 396 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 50588 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 779 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1061 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 67753 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1309 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41900 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 354 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1239 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19800 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82033 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1104 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1661 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 186 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47533 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1762 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 28200 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 369 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47200 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 844 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1182 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75507 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1964 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 62600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 379 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 96967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 2643 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42267 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 717 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 91713 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3052 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2559 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3734 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2278 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3355 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3820 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3405 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 46.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3000 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2502 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3904 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5767 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2304 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3552 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5451 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3088 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 84.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2698 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3957 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2389 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3550 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3027 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2609 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3726 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2267 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3436 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 14.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3824 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3459 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4920 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4222 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 212 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3400 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 233 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 415 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12967 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 40.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10400 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 660 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 169000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 876 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13947 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9756 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 826 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 207 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13187 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 412 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13113 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17575 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 574 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9185 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 131 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16733 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 513 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32825 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 560 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17927 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140600 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 612 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9786 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 576 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73680 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 468 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 119833 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 497 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 63575 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 206 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13173 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 417 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13350 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 687 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10919 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 128 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16427 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 59.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 111 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 474 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 121333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 550 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 547 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35033 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 573 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18367 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9766 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.1 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1281 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1190 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16575 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 975 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 121 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15487 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.664 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1412 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1363 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 440 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 112667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 555 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70885 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 546 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17475 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 561 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8971 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 130 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8332 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 233 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7461 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 385 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6165 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 688 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44000 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 720 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23033 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 755 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 615 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 157417 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 652 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83100 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 168 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 421 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 967 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 707 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10567 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4180 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3795 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3244 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 72.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4671 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2565 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 126 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4030 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2200 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 202 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3226 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3229 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2567 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 17.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4381 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5708 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2149 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 31.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3992 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5402 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 482 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 495 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 492 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 126000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 650 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 166333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 505 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8087 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 488 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 62433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 658 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 580 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 609 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 512 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 131000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 560 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8961 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 506 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 64733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 98.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25240 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 151 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19300 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 311 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19847 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 545 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17458 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.957 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1489 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 55.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 878 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1590 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 98.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 23.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1518 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 40.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1307 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19907 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 70.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1124 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 640 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20360 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 670 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 171467 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 662 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10573 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 690 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 88267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 613 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 157333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 620 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 79313 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 663 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 169667 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 844 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 843 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 53933 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1407 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45000 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1010 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1525 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24317 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44367 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 877 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 56100 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1176 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 936 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1380 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22067 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 969 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15500 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 64207 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1467 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46887 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 205 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52400 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 648 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 166000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1531 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 397 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 50700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 779 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 718 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45940 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1196 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38280 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1010 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1517 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24267 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1145 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73223 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1674 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 53547 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 205 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52147 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1753 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 28033 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 361 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46200 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 844 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3189 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 82.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2636 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3856 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5649 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 141 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2251 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3539 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5466 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3055 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 82.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2634 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4059 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 143 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2284 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3678 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3123 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5103 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2508 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 145 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4623 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 129 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2066 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 241 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3854 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3108 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2667 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3891 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5690 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 148 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2368 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 28.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3577 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5462 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3052 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2613 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3863 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5612 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2294 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3571 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5251 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3080 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 82.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2631 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3935 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 143 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2286 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3515 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9224 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 936 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 287 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9195 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1002 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 433 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6925 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15178 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 447 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 658 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 168667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 889 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14225 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9921 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 828 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 587 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19667 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 446 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 113917 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 582 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 149250 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 647 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10334 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 498 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 63640 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 76433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35287 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 581 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18527 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 547 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 599 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9578 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 236 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 436 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13947 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.20 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9776 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 680 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 174000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 872 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13783 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 75.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9670 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 829 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 204 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13020 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 448 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14280 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 65.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 786 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12520 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 133 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16827 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 621 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20527 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 529 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 135000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 652 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10435 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 583 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74633 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 469 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 120000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 562 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71920 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 233 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 420 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13342 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.515 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1375 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 647 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10350 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 10.24 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1298 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 94.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1317 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.2 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1187 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 62.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15993 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 983 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 122 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 596 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38007 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 630 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19960 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 557 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 142733 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 652 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10413 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74767 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 475 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 121667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 567 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72487 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 696 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 725 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 743 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11883 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 53.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 114.3 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14640 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 169 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 424 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13567 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 936 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 792 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 50667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1034 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33067 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1302 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 522 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 133333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 88733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 176 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 427 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 948 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15167 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 551 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3250 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2664 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 145 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2322 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4206 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3858 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 538 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 545 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7827 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 57.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7419 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3307 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5057 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2596 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4217 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2186 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 210 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3360 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 507 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 677 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 510 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 679 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21700 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 433 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6934 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 677 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 589 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 602 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 498 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 127333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 665 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 170667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9499 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 497 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 63600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 672 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 86000 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 208 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13240 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 283 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9064 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 407 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6506 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 103 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 26467 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 153 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19580 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 485 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 124200 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 522 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 66760 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 106 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 27133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 151 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.762 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1687 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1635 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1367 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 177 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1239 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 300 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9595 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1088 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 450 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7200 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 302 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 523 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.682 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1670 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 823 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1602 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 98.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 719 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 742 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 152667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 642 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 164000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 737 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11692 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 646 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 696 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 89067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 662 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42280 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 670 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21353 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 624 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 160000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 631 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10016 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 633 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80993 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 659 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 168667 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 844 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 651 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 166667 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 781 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99633 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 698 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44667 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 876 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 55400 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1229 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 933 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29867 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1616 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25867 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 967 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 713 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45333 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1238 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39613 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1880 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29733 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3109 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5053 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2590 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4414 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2293 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 221 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3542 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3031 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2504 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3905 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5666 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 139 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2220 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 26.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3443 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5412 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5605 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5415 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3111 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5122 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2545 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4535 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2385 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 233 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3729 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3150 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4989 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2584 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4291 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2263 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 218 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3497 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3072 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2554 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 15.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3878 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5606 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 140 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2234 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 27.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3520 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5384 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 410 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 104667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 627 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9326 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 935 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 292 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9349 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 520 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8313 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 544 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34800 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 591 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 634 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9346 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 655 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10471 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 585 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19487 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 474 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 121000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 557 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 142667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9820 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 508 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 65053 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 604 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 76900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9504 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 935 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59800 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 305 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9750 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 484 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7746 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 244 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 426 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 678 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 173333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 895 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14162 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.5 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10301 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 829 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 630 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40314 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20520 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 443 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 113667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 582 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 149000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 671 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10743 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 625 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80033 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 599 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38033 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 552 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 618 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9886 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 591 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 19.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1240 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 171 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.0 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1115 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 291 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9312 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 61.0 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 973 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 454 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7255 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 224 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 432 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13818 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 5.489 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1368 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 49.3 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 9.844 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1249 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 94.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12125 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 616 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39413 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20500 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 457 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 117000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 606 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 155000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 651 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10431 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 537 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 68740 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80933 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 601 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 603 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19283 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140533 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 653 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10433 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 605 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 77433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 274 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19100 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1077 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 124.6 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15853 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 54.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13817 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 127.8 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16292 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 535 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 136667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 702 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 89567 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 703 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44450 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 953 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1240 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 52.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 107 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 168 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 417 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 895 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 522 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 555 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 514 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8215 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 513 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 131333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 526 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 67400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4179 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3827 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3208 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2576 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2266 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 539 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 544 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 510 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8159 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 508 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 130000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 534 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 68367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5058 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4210 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 211 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3376 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5727 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 43.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5540 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 660 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 169000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 666 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 85233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37150 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 740 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 600 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 745 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 548 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8768 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 743 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11900 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 201 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25760 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 215 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 281 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8985 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 396 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6331 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 479 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30620 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 486 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15527 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 485 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7762 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 463 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 118600 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 497 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 63650 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 223 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 284 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9086 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 400 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6396 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 103 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 26500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 160 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 464 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 118667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 490 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 62687 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1430 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1222 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 69.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1107 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.870 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1714 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 13.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1663 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 464 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 119000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 478 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61233 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9590 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 72.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9295 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1446 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 181 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 39.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1261 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 314 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10024 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 69.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1123 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 457 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7307 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 635 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 710 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45433 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 644 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 731 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 656 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 755 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 737 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 736 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23233 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 643 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 164333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 644 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 164667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 745 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11811 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 629 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80373 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 88700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 879 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 56233 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 937 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 966 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15467 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 653 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 167000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 782 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99967 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5653 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5410 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 47.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3023 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5013 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2529 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 137 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4395 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 139 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2221 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 226 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3608 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5085 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 142 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4553 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 244 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3897 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.4 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5723 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.9 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5489 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5657 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5408 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 48.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3078 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5058 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.6 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2544 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 139 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4428 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 139 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2220 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 223 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3569 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 932 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59667 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16667 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 405 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 104000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 627 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80167 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 152000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 76500 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 556 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35553 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 583 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18657 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 634 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20050 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9338 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 643 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10300 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 201 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 51317 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69287 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 165 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 933 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59733 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 339 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10834 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 546 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8741 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 602 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 640 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40933 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 612 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19520 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 689 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22067 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 595 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9508 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 704 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11267 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 654 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 687 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22000 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 456 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 116800 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 570 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 146000 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 728 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11640 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 556 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70960 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.9 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9181 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.8 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8802 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 20.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1322 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 179 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.4 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1193 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 293 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9368 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.6 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1030 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 448 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7167 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 554 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 634 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 674 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21513 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 607 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9710 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 702 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11233 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 617 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 620 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19745 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 472 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 120667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156500 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 659 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10539 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 630 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 258 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16492 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 640 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 668 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 171333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1159 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 256 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16387 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1040 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17058 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 779 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 958 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1118 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 705 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 524 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 134000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 675 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 86133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 235 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14700 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 519 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 56.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1018 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 106 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13620 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 52.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 109 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14000 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 139000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 547 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70000 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 563 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36033 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 476 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7613 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3310 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2656 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 17.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4349 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 151 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2403 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 32.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4089 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4223 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3944 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 568 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 571 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 499 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7987 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4910 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4223 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 209 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3338 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 670 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 677 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21700 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 679 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 665 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 170000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 671 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 85867 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 254 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16250 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 305 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9762 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 797 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 204333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 402 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6420 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 887 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 113333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 147 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37760 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 201 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 555 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 142267 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69433 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 440 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 28180 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 437 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13892 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 474 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7578 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 127 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32580 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 174 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 212 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13443 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 280 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8946 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 402 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6426 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 485 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 479 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15320 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 551 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8811 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 457 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 117333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 482 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 7.086 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1768 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 13.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1666 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1448 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 39.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1271 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 70.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1124 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 496 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 508 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 512 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8190 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 434 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 110987 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 469 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59987 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8457 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 233 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7441 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 378 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6052 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9906 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 71.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9105 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 678 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 173667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 703 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90000 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 642 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 706 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 45200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 636 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20340 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 720 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 636 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10194 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 726 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 875 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 55933 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 933 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29867 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 962 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15400 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 947 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60600 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.8 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5038 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 135 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4327 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 219 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3504 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5622 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.1 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5382 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 79.0 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5048 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 141 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4495 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 231 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3689 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4937 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 134 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4294 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 219 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3492 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5561 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.7 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5331 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 932 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40043 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20418 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 588 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 150600 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 78525 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 930 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1042 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 208 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 53200 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 78217 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 599 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 153333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 629 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 585 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37373 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 666 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42600 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 620 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19833 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 690 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21733 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 623 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9965 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 716 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11467 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 129 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8235 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 228 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7283 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 371 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5931 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.9 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9177 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 71.7 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9176 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 152800 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 634 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81133 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36960 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 681 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43567 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 618 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19525 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 687 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21967 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 599 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9577 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 694 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 169 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 945 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 421 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1008 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 962 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1040 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 260 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16647 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19040 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 674 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 172333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1095 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17520 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 793 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 50733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1001 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32033 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 539 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 137667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1145 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 699 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 89450 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 861 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 110000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 763 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 48133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1021 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 537 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 137333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1300 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 708 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15269 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17273 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 692 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1064 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17033 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 218 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13671 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 504 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16100 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 56.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1010 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 108 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 566 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 543 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 139333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8844 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 566 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 530 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 135667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 541 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3272 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2671 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4307 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7552 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 149 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2374 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3798 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 56.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7242 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 50.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3243 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 84.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2693 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 16.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4139 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 154 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2457 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 29.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3831 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 565 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36167 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 574 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 587 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9388 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 565 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 536 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 137333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 727 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 733 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 725 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 821 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 52513 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 846 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 26733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 76.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19475 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 660 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 169000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 895 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14314 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 114 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14447 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 820 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 104667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 250 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15975 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 306 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9773 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 793 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 203000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 406 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6496 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 796 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 101667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 559 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17867 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 562 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 143667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 601 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9609 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 572 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73220 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 550 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 563 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72075 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 237 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 295 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9438 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 766 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 196000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 399 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6379 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 804 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 103000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 128 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32650 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 168 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21467 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 505 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 129333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 579 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 518 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33147 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 516 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16442 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 510 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8155 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1465 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 39.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1251 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 73.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18833 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1100 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.692 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1669 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1646 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 534 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 136867 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73900 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 535 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 507 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16233 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 462 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7385 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 135 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8642 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 230 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7378 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 383 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6126 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 720 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 737 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 736 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 644 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 165000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 704 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 90167 |===================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 78.2 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5001 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4399 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 222 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3549 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 77.5 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4955 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4238 |====================================== Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 217 |======================================= Flexible IO Tester 3.25 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3464 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40090 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 619 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19792 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 638 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10192 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 930 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1003 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 671 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42900 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 705 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 718 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11500 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 607 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 155667 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 622 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 79638 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 129 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8267 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 231 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7387 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 371 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5941 |====================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 655 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 41967 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 698 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22367 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 703 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11233 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 568 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 145333 |==================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 628 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 675 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 173000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 172 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 942 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 416 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1001 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32000 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 915 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14620 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1022 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 747 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47827 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 945 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1057 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 970 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1347 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21414 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 961 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15350 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 770 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1023 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32475 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 530 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 135667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 591 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 151000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1333 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 681 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 86833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 786 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 100667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 171 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 942 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 420 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 954 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 925 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1034 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 239 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 529 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 42.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 692 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 994 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 85.5 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 564 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 566 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 538 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 611 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 567 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9074 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 628 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 588 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 526 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 134667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 605 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9668 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 555 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 71033 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 52.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3374 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 74.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4776 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 85.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2739 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 124 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3954 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 156 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2485 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 198 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3167 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3262 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2670 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 17.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4400 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 23.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5986 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 145 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2316 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 31.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4045 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 41.8 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5353 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 565 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 144667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 624 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 159667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 582 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9306 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 565 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72267 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 628 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 593 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 605 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 583 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9327 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 565 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 159 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10194 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 939 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 213 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6806 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1004 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 277 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4432 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 896 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 57333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 930 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 661 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 169333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 999 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 117 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14950 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 831 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20533 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 601 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 154000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 619 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 158667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 649 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10380 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 581 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74375 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 78511 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 596 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 153333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 607 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9702 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 589 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75433 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 847 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 54057 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 902 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 28800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 80.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 682 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 174667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 982 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 112.7 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14427 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 832 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 106000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 227 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14533 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 309 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9883 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 830 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 212333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 407 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6511 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 869 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 111333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 624 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39927 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 627 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19987 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 531 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 135889 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10115 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 577 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73807 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 579 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 148000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 625 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 79933 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 323 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20636 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 584 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18687 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.201 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1546 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 52.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13287 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 733 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11720 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 12.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1535 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 97.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12467 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 22.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1416 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 38.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1233 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 81.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20687 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 67.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1081 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 170 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21736 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39173 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 643 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140733 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 619 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9909 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 605 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 77400 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141733 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 76000 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 730 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 740 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23675 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 736 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11767 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 667 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42633 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 704 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 721 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11533 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 665 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 42540 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 698 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22333 |===================================== Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 700 |======================================= Flexible IO Tester 3.25 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11167 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 945 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1040 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 669 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 171000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 844 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 866 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 111000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 734 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46967 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 958 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 925 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 29473 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 967 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 30933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1162 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 966 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 693 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 165 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 944 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 407 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1011 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 901 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 14433 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 541 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 779 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 553 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 789 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 478 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7655 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 789 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 576 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 587 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 514 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 131667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 763 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 195333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9240 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 531 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 68000 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 769 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 98467 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 30.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7746 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 57.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7303 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 3308 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 115 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7382 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 83.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2670 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 199 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6358 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 146 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 2331 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 318 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5089 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 544 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34767 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 779 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 547 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 790 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 25300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 484 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7746 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 792 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12667 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 576 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36900 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 536 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 137333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 765 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 195667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 573 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9168 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 542 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 69400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 775 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 99233 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 408 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 104667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 648 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82967 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 136 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8735 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 939 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 198 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6324 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1004 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 260 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4158 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 525 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 33580 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 520 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16520 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 641 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 545 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8710 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 635 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10164 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 610 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 39033 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 612 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19527 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 511 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 130667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 606 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 155000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10221 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 568 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 72693 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 626 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 136 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8672 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 938 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 192 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6149 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 260 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4164 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 738 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47120 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 771 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 68.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 682 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 174667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 805 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12867 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 98.6 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12550 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 832 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 107000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 563 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35913 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 592 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18920 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 550 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 141000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 614 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 157333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 646 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 591 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 606 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 625 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20000 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10242 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 578 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 73975 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1396 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 174 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11040 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 35.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1145 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 297 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9494 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1027 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 452 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7234 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 300 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 534 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 6.439 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1606 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 51.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 13100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 740 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11833 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 11.9 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1524 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 97.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12433 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 588 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37527 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19047 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 540 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 612 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156733 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 595 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9519 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 625 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 79933 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 670 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 85680 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 38275 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 628 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20013 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 590 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 151000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10099 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 627 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80193 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 944 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1040 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 941 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 973 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31133 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 973 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 709 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 181333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 857 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 110000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 944 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1009 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1040 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 692 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 177000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 845 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 108000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 733 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 187667 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 741 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 94833 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 561 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 35933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 744 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 573 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 737 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 558 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8919 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 734 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 113 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7254 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 194 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6215 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 307 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4915 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 33.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8469 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 64.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8204 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 734 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 188333 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 750 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 95967 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 572 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36567 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 740 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 47333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 571 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 17933 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 739 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 551 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8815 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 737 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 937 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59900 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 405 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 103667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 657 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 84067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 164667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 631 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 80800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 544 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 34808 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 632 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40400 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 564 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 18067 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 624 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19967 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 568 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9077 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 669 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10693 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 238 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60860 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 488 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 62371 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 144 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9209 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 937 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59933 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 201 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6418 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 261 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4168 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 590 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 680 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43525 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19100 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 699 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 600 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9595 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 709 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 587 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37543 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 619 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19467 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 539 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 138000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 616 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 158000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 620 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9920 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 582 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 74467 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 639 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 36.3 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9287 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 71.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9131 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 21.7 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1387 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 174 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11167 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.2 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1185 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 304 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9731 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 65.1 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 1038 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 448 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7161 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 589 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37425 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 677 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43347 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 603 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19267 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 706 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 594 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9500 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 699 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 633 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 677 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 21633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 550 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 140667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 628 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 161000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 700 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_writeback IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 593 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 75600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 651 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 83333 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 953 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60967 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 976 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 31233 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 970 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 15533 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 944 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 60400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1010 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32300 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1041 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16633 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 772 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 775 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24800 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 774 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 746 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 191000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 758 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 96733 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 114 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7286 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 197 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6298 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 306 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 4885 |====================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 772 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 49400 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 777 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 24867 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 780 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 12500 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 755 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 193000 |==================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 762 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 97567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 935 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59900 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 633 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 650 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 672 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10680 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 624 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 159733 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 635 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 81300 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 930 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59533 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 240 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 61360 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 549 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 70180 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 621 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 159000 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 645 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 82533 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 572 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 36407 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 684 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 597 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19133 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 708 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 598 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9558 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 709 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11333 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 132 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8418 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 232 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7425 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 375 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 5992 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 37.4 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9577 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 72.0 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9212 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 601 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 153667 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 667 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 85050 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 589 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 37667 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 688 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44000 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 606 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 19400 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 705 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22567 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 609 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/ceph_virtio_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 9743 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 711 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_baseline IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11367 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 721 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46167 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 726 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 726 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11600 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 719 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 46033 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 726 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 23200 |===================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 728 |======================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 638 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 40800 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 655 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 20933 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 647 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 10367 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 933 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 59733 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1005 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 32200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 1043 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 16700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 699 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 719 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22967 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 746 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 615 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 157333 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 673 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 86200 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 138 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 8823 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 242 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 7754 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 383 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 6125 |====================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 687 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43900 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 713 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22500 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 730 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11700 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 613 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 156733 |==================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 668 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 85373 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 700 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 44767 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 717 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22600 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 747 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 685 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 43817 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 706 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 22633 |===================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync MB/s > Higher Is Better CEPH vs local lvm FIO comparison . 716 |======================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/thinpool_scsi_directsync IOPS > Higher Is Better CEPH vs local lvm FIO comparison . 11433 |=====================================