reiserfs_ST3000DM001-1ER1 Intel Core i7-5930K testing with a ASRock X99 Extreme6/3.1 (P1.20 BIOS) and NVIDIA GeForce GTX 780 3GB on openSUSE 15.2 via the Phoronix Test Suite. vierterFS test: Processor: Intel Core i7-5930K @ 3.70GHz (6 Cores / 12 Threads), Motherboard: ASRock X99 Extreme6/3.1 (P1.20 BIOS), Chipset: Intel Xeon E7 v3/Xeon, Memory: 64GB, Disk: 256GB SAMSUNG MZVLV256HCHP-00000 + 2 x 3001GB Seagate ST3000DM001-1ER1 + 2 x 3001GB TOSHIBA HDWD130 + 2GB Flash Disk, Graphics: NVIDIA GeForce GTX 780 3GB, Audio: Realtek ALC1150, Monitor: BenQ G2225HD, Network: Intel I218-V + Qualcomm Atheros QCA8171 OS: openSUSE 15.2, Kernel: 5.3.18-lp152.75-preempt (x86_64), Desktop: KDE 4.14.38, Display Server: X Server 1.20.11, Display Driver: NVIDIA 460.80, OpenGL: 4.6.0, Vulkan: 1.2.155, Compiler: GCC 7.5.0 + Clang 9.0.1 + LLVM 9.0.1 + CUDA 11.1, File-System: ext4, Screen Resolution: 1920x1080 Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 1.628 |======================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 403 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 175 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 18 |========================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 12.0 |======================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 384 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 1.639 |======================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 406 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 174 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 18 |========================================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 1.262 |======================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 312 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 165 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 17 |========================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 95.6 |======================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 188 |========================================================= Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 12.1 |======================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 385 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 9.721 |======================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 303 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 1.306 |======================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 323 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 164 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 17 |========================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 95.0 |======================================================== Flexible IO Tester 3.25 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 186 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 79.7 |======================================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 156 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 9.678 |======================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 299 |========================================================= Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 80.1 |======================================================== Flexible IO Tester 3.25 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 157 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 172 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 43767 |======================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 195 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 21 |========================================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 173 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 5518 |======================================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 172 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 44033 |======================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 195 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 21 |========================================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 133 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 33633 |======================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 187 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 20 |========================================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 173 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 342 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 173 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 5517 |======================================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 164 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 5233 |======================================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 120 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 30742 |======================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 187 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 20 |========================================================== Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 173 |========================================================= Flexible IO Tester 3.25 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 341 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 165 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 327 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 163 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 5209 |======================================================== Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 MB/s > Higher Is Better vierterFS test . 166 |========================================================= Flexible IO Tester 3.25 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /tmp2 IOPS > Higher Is Better vierterFS test . 329 |=========================================================