FIO Sabrent Rocket 4.0 Plus 1TB AMD Ryzen 7 5800X 8-Core testing with a ASRock X570 Pro4 (P3.40 BIOS) and Sapphire AMD Radeon RX 470/480/570/570X/580/580X/590 8GB on Ubuntu 20.10 via the Phoronix Test Suite. Sabrent: Processor: AMD Ryzen 7 5800X 8-Core @ 3.80GHz (8 Cores / 16 Threads), Motherboard: ASRock X570 Pro4 (P3.40 BIOS), Chipset: AMD Starship/Matisse, Memory: 16GB, Disk: 1000GB Sabrent Rocket 4.0 Plus, Graphics: Sapphire AMD Radeon RX 470/480/570/570X/580/580X/590 8GB (1560/2100MHz), Audio: AMD Ellesmere HDMI Audio, Monitor: G237HL, Network: Intel I211 OS: Ubuntu 20.10, Kernel: 5.8.0-31-generic (x86_64), Desktop: GNOME Shell 3.38.1, Display Server: X Server 1.20.9, Display Driver: modesetting 1.20.9, OpenGL: 4.6 Mesa 20.2.1 (LLVM 11.0.0), Vulkan: 1.2.131, Compiler: GCC 10.2.0, File-System: ext4, Screen Resolution: 1920x1080 Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 487 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3922 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2104 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4215 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 490 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3945 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 239000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 933 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1805 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3618 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 497 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1001 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 294000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1150 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 546 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1100 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 215 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1747 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 220000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 858 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 163 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1332 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1851 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3709 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 151 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1233 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 150 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1232 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1237 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2481 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 152 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1242 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 161 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1314 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 539 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4318 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1298 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2597 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 183 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1493 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 183 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1493 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 183 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1494 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 540 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4346 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2872 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5750 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1143 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2294 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 369 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2979 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 538 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4337 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1107 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2222 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 406 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3279 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 538 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4331 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 466 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3759 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 537 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4324 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 402 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3244 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 457000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1784 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 289 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2343 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 446000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1742 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 266 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2161 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 336 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2691 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 375 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3028 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 287 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2328 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 291 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2357 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 309 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2500 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 308 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2495 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2840 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5688 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1165 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2337 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 329 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2633 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 402 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3245 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 284 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2303 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1092 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2190 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 428 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3453 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 471000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1840 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 326 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2612 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 465 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3749 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 434 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3503 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 450 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3626 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2870 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5747 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 184 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1497 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 467000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1823 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 463000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1807 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1338 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2677 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 612 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1232 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 16200 |============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 63.3 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 174000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 679 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 541000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2113 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 430000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1680 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 431000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1685 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 681 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5437 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 289000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1130 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 18300 |============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 71.5 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2981 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5969 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2344 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4696 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 743 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5970 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2979 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5966 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 150 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1229 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 338 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2705 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 303000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1184 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2405 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4811 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 337 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2702 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1222 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2446 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 616 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1233 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 739 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5923 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 302000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1182 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 327000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1276 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2408 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4817 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 495 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 991 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 13500 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 52.6 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2158 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4324 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1898 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3804 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 672 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5359 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 97500 |============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 381 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 17600 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 68.9 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 98900 |============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 387 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 25000 |============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 97.8 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2461 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4923 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 151 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1211 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 120 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 964 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 638 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5109 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 447000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1745 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 295000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1153 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 545000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2131 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1262 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2531 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 450000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1757 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 503000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1964 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 18400 |============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 71 |================================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1291 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2583 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 17600 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 68.9 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 17400 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 67.9 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2490 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4986 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 491000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1918 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 765 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 6149 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 97300 |============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 380 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 13500 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 52.6 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 545000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2127 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1224 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2456 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 462000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1803 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 522000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2040 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1214 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2436 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 97600 |============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 381 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2158 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4323 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1137 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2281 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 308 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2493 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1187 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2381 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 58000 |============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 230 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 319000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1246 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2160 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4327 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2491 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4990 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 426000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1665 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1163 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2333 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 672 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5404 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2087 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4181 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 311 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2517 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1185 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2377 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 209000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 818 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 262000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1023 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2336 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4680 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 641 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5154 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 743 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5970 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 201000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 786 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 257000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1002 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 200000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 783 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 205000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 800 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2987 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5981 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1211 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2429 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 393000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1533 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 550000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2150 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2161 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4330 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 293000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1143 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1270 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2547 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 606 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1220 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 596 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1199 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 560000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2188 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 93500 |============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 365 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2158 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4317 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 454000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1774 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1249 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2498 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 67200 |============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 263 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2492 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4992 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 497000 |============================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1942 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 602 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1212 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 673 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5412 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 18800 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 73.5 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2037 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4081 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 151 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1236 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 17700 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 69.1 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 496 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 999 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 173000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 675 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 752 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 6027 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2280 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4567 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 621 |================================================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4968 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 454000 |============================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1775 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 665 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5323 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2491 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4988 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 670 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5386 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 18900 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 73.7 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1917 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3842 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2243 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4493 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 3079 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 6165 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 666 |================================================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5332 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1816 |=============================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3634 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 173000 |============================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 677 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 2934 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5875 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 335 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2684 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1339 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 2679 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 618 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4951 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 17800 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 69.4 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 594 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 1189 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 567 |================================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 4540 |=============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 97500 |============================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 381 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 13000 |============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 50.8 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1661 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3323 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 655 |================================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 5245 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Sabrent . 1632 |=============================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Sabrent . 3265 |===============================================================