NVME_RAID10_XFS_ALL_TESTS

2 x Intel Xeon E5-2680 v4 testing with a HP ProLiant DL380 Gen9 (P89 BIOS) and Matrox MGA G200EH on Ubuntu 20.04 via the Phoronix Test Suite.

Compare your own system(s) to this result file with the Phoronix Test Suite by running the command: phoronix-test-suite benchmark 2009094-CHOC-NVMERAI43
Jump To Table - Results

Statistics

Remove Outliers Before Calculating Averages

Graph Settings

Prefer Vertical Bar Graphs

Multi-Way Comparison

Condense Multi-Option Tests Into Single Result Graphs

Table

Show Detailed System Result Table

Run Management

Result
Identifier
Performance Per
Dollar
Date
Run
  Test
  Duration
NVME_RAID10_XFS_ALL_TESTS
September 08 2020
  8 Hours, 57 Minutes
Only show results matching title/arguments (delimit multiple options with a comma):
Do not show results matching title/arguments (delimit multiple options with a comma):


NVME_RAID10_XFS_ALL_TESTS 2 x Intel Xeon E5-2680 v4 testing with a HP ProLiant DL380 Gen9 (P89 BIOS) and Matrox MGA G200EH on Ubuntu 20.04 via the Phoronix Test Suite. NVME_RAID10_XFS_ALL_TESTS: Processor: 2 x Intel Xeon E5-2680 v4 @ 3.30GHz (28 Cores / 56 Threads), Motherboard: HP ProLiant DL380 Gen9 (P89 BIOS), Chipset: Intel Xeon E7 v4/Xeon, Memory: 190GB, Disk: 4 x 2000GB VO002000KWJSF + 500GB LOGICAL VOLUME, Graphics: Matrox MGA G200EH, Monitor: Smart Cable, Network: 4 x Broadcom NetXtreme BCM5719 PCIe OS: Ubuntu 20.04, Kernel: 5.4.0-45-generic (x86_64), Compiler: GCC 9.3.0, File-System: xfs, Screen Resolution: 1024x768 Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4530 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2267 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 8953 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2239 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 18167 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2270 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 31850 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1986 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4643 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2324 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 9037 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2260 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 17617 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2201 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 13600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6809 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 27200 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6810 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 54367 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6798 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 286 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2314 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 571 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2296 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1157 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2321 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2310 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2314 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 31267 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1955 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 52567 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1643 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 73533 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4596 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 125667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3930 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 179333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2801 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 13600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6804 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 27200 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6809 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 54367 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6796 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 278 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2254 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 585 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2354 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 93780 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 367 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1135 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2277 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2090 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2093 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 574 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4622 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 192667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1506 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1130 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4534 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 212333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 829 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2351 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4709 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4813 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4817 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 64975 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4078 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 111333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3470 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 163333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2549 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 688 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5531 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 189067 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1477 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1693 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6789 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 213000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 832 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3401 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6810 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6806 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6809 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4432 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2218 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 9041 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2261 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 18167 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2274 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 30733 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1922 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 51920 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1623 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 83100 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1301 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4695 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2349 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 9207 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2303 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 18033 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2254 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 13600 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6804 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 27200 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6807 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 54300 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6786 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 286 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2319 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 90487 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 707 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 581 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2337 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 96860 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 378 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1190 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2387 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2341 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2344 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 30067 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1877 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 53263 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1665 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 82040 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1282 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 68233 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4266 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 117333 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3665 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 175000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2732 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 13567 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6792 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 27200 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6806 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 54300 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6784 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 287 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2329 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 89447 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 699 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 567 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2283 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 94013 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 367 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1155 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2317 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2306 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2309 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 600 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4825 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 190667 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1491 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1234 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4952 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 212000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 829 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2528 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5063 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5163 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5167 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 66533 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 4179 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 114667 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3580 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 169333 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 2648 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 701 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5640 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 184333 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1438 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1487 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 5960 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 204667 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 799 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 3078 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6163 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6526 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 6530 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 49887 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1561 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 83727 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1308 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 91747 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 717 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 98147 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 383 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 83173 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 1300 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 91053 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better NVME_RAID10_XFS_ALL_TESTS . 712 |==============================================