2 x Intel Xeon E5-2403 v2 testing with a Dell 0JD6X3 (2.4.2 BIOS) and Matrox G200eR2 on CentOS Linux 7 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 2009025-NE-MERGE611613
storage
2 x Intel Xeon E5-2403 v2 testing with a Dell 0JD6X3 (2.4.2 BIOS) and Matrox G200eR2 on CentOS Linux 7 via the Phoronix Test Suite.
synology:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 1000GB VTrak D5800, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.18.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
freenas-96:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 1000GB VTrak D5800, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.18.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
freenas-97:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 1000GB VTrak D5800, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.18.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
synology-mtu9000:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 21475GB iSCSI Storage, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.19.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
freenas-96-mtu9000:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 21475GB iSCSI Storage, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.19.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
freenas-97-mtu9000:
Processor: 2 x Intel Xeon E5-2403 v2 @ 1.80GHz (8 Cores), Motherboard: Dell 0JD6X3 (2.4.2 BIOS), Chipset: Intel Xeon E7 v2/Xeon, Memory: 4 x 8192 MB DDR3-1333MT/s, Disk: 199GB PERC H310 + 21475GB iSCSI Storage, Graphics: Matrox G200eR2, Network: 2 x Broadcom NetXtreme BCM5720 2-port PCIe + 2 x Intel 82599ES 10-Gigabit SFI/SFP+
OS: CentOS Linux 7, Kernel: 3.10.0-1127.19.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 160 |=========================================
freenas-96 ......... 148 |======================================
freenas-97 ......... 143 |====================================
synology-mtu9000 ... 130 |=================================
freenas-96-mtu9000 . 209 |=====================================================
freenas-97-mtu9000 . 177 |=============================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 41067 |=======================================
freenas-96 ......... 37867 |====================================
freenas-97 ......... 36700 |===================================
synology-mtu9000 ... 33233 |================================
freenas-96-mtu9000 . 53433 |===================================================
freenas-97-mtu9000 . 45300 |===========================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 156 |============================================
freenas-96 ......... 144 |=========================================
freenas-97 ......... 136 |=======================================
synology-mtu9000 ... 141 |========================================
freenas-96-mtu9000 . 186 |=====================================================
freenas-97-mtu9000 . 185 |=====================================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 39533 |==========================================
freenas-96 ......... 36833 |=======================================
freenas-97 ......... 34967 |=====================================
synology-mtu9000 ... 36033 |=======================================
freenas-96-mtu9000 . 47667 |===================================================
freenas-97-mtu9000 . 47433 |===================================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 15.700 |=================================
freenas-96 ......... 13.200 |============================
freenas-97 ......... 9.857 |=====================
synology-mtu9000 ... 23.500 |==================================================
freenas-96-mtu9000 . 13.000 |============================
freenas-97-mtu9000 . 10.900 |=======================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4003 |==================================
freenas-96 ......... 3373 |=============================
freenas-97 ......... 2501 |=====================
synology-mtu9000 ... 6105 |====================================================
freenas-96-mtu9000 . 3312 |============================
freenas-97-mtu9000 . 2783 |========================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 152.0 |=====================================
freenas-96 ......... 206.0 |===================================================
freenas-97 ......... 163.0 |========================================
synology-mtu9000 ... 96.8 |========================
freenas-96-mtu9000 . 207.0 |===================================================
freenas-97-mtu9000 . 163.0 |========================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 38867 |=====================================
freenas-96 ......... 52467 |==================================================
freenas-97 ......... 41633 |========================================
synology-mtu9000 ... 24767 |========================
freenas-96-mtu9000 . 53000 |===================================================
freenas-97-mtu9000 . 41700 |========================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 15.70 |=================================
freenas-96 ......... 12.30 |==========================
freenas-97 ......... 9.96 |=====================
synology-mtu9000 ... 24.00 |===================================================
freenas-96-mtu9000 . 11.60 |=========================
freenas-97-mtu9000 . 11.10 |========================
Flexible IO Tester 3.18
Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4005 |==================================
freenas-96 ......... 3133 |==========================
freenas-97 ......... 2549 |======================
synology-mtu9000 ... 6154 |====================================================
freenas-96-mtu9000 . 3042 |==========================
freenas-97-mtu9000 . 2849 |========================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 162 |=========================================
freenas-96 ......... 188 |================================================
freenas-97 ......... 172 |============================================
synology-mtu9000 ... 172 |============================================
freenas-96-mtu9000 . 209 |=====================================================
freenas-97-mtu9000 . 148 |======================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 41433 |========================================
freenas-96 ......... 48133 |==============================================
freenas-97 ......... 43600 |==========================================
synology-mtu9000 ... 44033 |==========================================
freenas-96-mtu9000 . 53367 |===================================================
freenas-97-mtu9000 . 37533 |====================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 443 |===============================================
freenas-96 ......... 461 |=================================================
freenas-97 ......... 442 |===============================================
synology-mtu9000 ... 455 |=================================================
freenas-96-mtu9000 . 497 |=====================================================
freenas-97-mtu9000 . 478 |===================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 113333 |=============================================
freenas-96 ......... 118000 |==============================================
freenas-97 ......... 113000 |============================================
synology-mtu9000 ... 116667 |==============================================
freenas-96-mtu9000 . 127333 |==================================================
freenas-97-mtu9000 . 122000 |================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 437 |=================================================
freenas-96 ......... 453 |===================================================
freenas-97 ......... 436 |=================================================
synology-mtu9000 ... 468 |====================================================
freenas-96-mtu9000 . 464 |====================================================
freenas-97-mtu9000 . 474 |=====================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 112000 |==============================================
freenas-96 ......... 116000 |================================================
freenas-97 ......... 111667 |==============================================
synology-mtu9000 ... 119667 |=================================================
freenas-96-mtu9000 . 118667 |=================================================
freenas-97-mtu9000 . 121333 |==================================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 15.9 |=================================
freenas-96 ......... 12.3 |==========================
freenas-97 ......... 11.9 |=========================
synology-mtu9000 ... 24.7 |====================================================
freenas-96-mtu9000 . 13.5 |============================
freenas-97-mtu9000 . 11.0 |=======================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4060 |=================================
freenas-96 ......... 3159 |==========================
freenas-97 ......... 3047 |=========================
synology-mtu9000 ... 6328 |====================================================
freenas-96-mtu9000 . 3459 |============================
freenas-97-mtu9000 . 2820 |=======================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 16.3 |===================================
freenas-96 ......... 12.3 |==========================
freenas-97 ......... 11.9 |==========================
synology-mtu9000 ... 24.2 |====================================================
freenas-96-mtu9000 . 13.6 |=============================
freenas-97-mtu9000 . 11.1 |========================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4173 |===================================
freenas-96 ......... 3141 |==========================
freenas-97 ......... 3045 |==========================
synology-mtu9000 ... 6196 |====================================================
freenas-96-mtu9000 . 3487 |=============================
freenas-97-mtu9000 . 2838 |========================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 15.5 |=================================
freenas-96 ......... 12.3 |==========================
freenas-97 ......... 11.8 |=========================
synology-mtu9000 ... 24.3 |====================================================
freenas-96-mtu9000 . 13.0 |============================
freenas-97-mtu9000 . 11.0 |========================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 3962 |=================================
freenas-96 ......... 3149 |==========================
freenas-97 ......... 3017 |=========================
synology-mtu9000 ... 6224 |====================================================
freenas-96-mtu9000 . 3333 |============================
freenas-97-mtu9000 . 2820 |========================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 16.96 |==================================
freenas-96 ......... 25.50 |===================================================
freenas-97 ......... 21.80 |============================================
synology-mtu9000 ... 17.33 |===================================
freenas-96-mtu9000 . 25.40 |===================================================
freenas-97-mtu9000 . 23.30 |===============================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4324 |==================================
freenas-96 ......... 6526 |====================================================
freenas-97 ......... 5588 |=============================================
synology-mtu9000 ... 4422 |===================================
freenas-96-mtu9000 . 6493 |====================================================
freenas-97-mtu9000 . 5953 |===============================================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 15.40 |=================================
freenas-96 ......... 13.80 |==============================
freenas-97 ......... 9.96 |======================
synology-mtu9000 ... 23.50 |===================================================
freenas-96-mtu9000 . 11.70 |=========================
freenas-97-mtu9000 . 11.10 |========================
Flexible IO Tester 3.18
Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 3953 |==================================
freenas-96 ......... 3533 |===============================
freenas-97 ......... 2548 |======================
synology-mtu9000 ... 6023 |====================================================
freenas-96-mtu9000 . 2988 |==========================
freenas-97-mtu9000 . 2857 |=========================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 19.1 |=======================================
freenas-96 ......... 25.3 |====================================================
freenas-97 ......... 24.6 |===================================================
synology-mtu9000 ... 20.6 |==========================================
freenas-96-mtu9000 . 24.7 |===================================================
freenas-97-mtu9000 . 21.1 |===========================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 4891 |=======================================
freenas-96 ......... 6475 |====================================================
freenas-97 ......... 6294 |===================================================
synology-mtu9000 ... 5271 |==========================================
freenas-96-mtu9000 . 6325 |===================================================
freenas-97-mtu9000 . 5476 |============================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 475 |=============================================
freenas-96 ......... 504 |================================================
freenas-97 ......... 530 |===================================================
synology-mtu9000 ... 501 |================================================
freenas-96-mtu9000 . 554 |=====================================================
freenas-97-mtu9000 . 538 |===================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 121333 |===========================================
freenas-96 ......... 129000 |==============================================
freenas-97 ......... 135667 |================================================
synology-mtu9000 ... 128333 |=============================================
freenas-96-mtu9000 . 141667 |==================================================
freenas-97-mtu9000 . 137667 |=================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
MB/s > Higher Is Better
synology ........... 516 |==================================================
freenas-96 ......... 515 |==================================================
freenas-97 ......... 543 |=====================================================
synology-mtu9000 ... 513 |==================================================
freenas-96-mtu9000 . 530 |====================================================
freenas-97-mtu9000 . 515 |==================================================
Flexible IO Tester 3.18
Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /
IOPS > Higher Is Better
synology ........... 132333 |================================================
freenas-96 ......... 131667 |===============================================
freenas-97 ......... 138667 |==================================================
synology-mtu9000 ... 131333 |===============================================
freenas-96-mtu9000 . 136000 |=================================================
freenas-97-mtu9000 . 131667 |===============================================