fsSync AMD EPYC 7401P 24-Core testing with a GIGABYTE MZ21-G20-00 v01000100 (F03d BIOS) and Gigabyte NVIDIA GeForce RTX 2080 Ti Rev. A 11GB on CentOS Linux 8 via the Phoronix Test Suite. fiona raid sync: Processor: AMD EPYC 7401P 24-Core @ 2.00GHz (24 Cores / 48 Threads), Motherboard: GIGABYTE MZ21-G20-00 v01000100 (F03d BIOS), Chipset: AMD 17h, Memory: 8 x 16384 MB DDR4-2667MT/s Samsung M393A2G40EB2-CTD, Disk: 2 x 3841GB Micron_9200_MTFDHAL3T8TCT + 8GB Flash Disk + 2 x 480GB Micron_5200_MTFD, Graphics: Gigabyte NVIDIA GeForce RTX 2080 Ti Rev. A 11GB, Audio: NVIDIA TU102 HD Audio, Monitor: Smart Cable, Network: 2 x Mellanox MT27710 + 2 x Mellanox MT27800 OS: CentOS Linux 8, Kernel: 4.18.0-80.11.2.el8_0.x86_64 (x86_64), Display Server: X Server 1.20.3, Compiler: GCC 8.3.1 20190507 + CUDA 10.2, File-System: xfs, Screen Resolution: 1024x768 Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2378 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 40.8 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10467 |====================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4609 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1152 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 5415 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 676 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2395 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2395 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 41.0 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10500 |====================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4590 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1147 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 5413 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 676 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1633 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1633 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 40.6 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10400 |====================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2769 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 692 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2565 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 320 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3006 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2986 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 197 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 50400 |====================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3380 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 844 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3415 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 426 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 407 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 3254 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1673 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1649 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 25.8 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 6597 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2790 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 697 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2593 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 323 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3035 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 197 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 50433 |====================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3366 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 841 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3430 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 429 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1433 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1433 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1016 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 260000 |===================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1432 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 357 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1425 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 178 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 386 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 3086 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 345 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2757 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1384 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10733 |====================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1433 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1437 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1019 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 261000 |===================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1431 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 357 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1423 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 177 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 361 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2890 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1373 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10000 |====================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1463 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 11733 |====================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2060 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2059 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 20.8 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 5313 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3978 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 994 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4806 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 600 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1453 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 11633 |====================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2313 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2283 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 24.5 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 6275 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4034 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1008 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4896 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 612 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4108 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 4110 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2526 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 646667 |===================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4109 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1027 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3456 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 432 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3019 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 3018 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 200 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 51233 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3388 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 847 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3410 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 426 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 392 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 3139 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4091 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 4128 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2555 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 654000 |===================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4101 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1025 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3449 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 431 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 2964 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 2979 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 201 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 51367 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3363 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 840 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 3404 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 425 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1438 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1437 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1221 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 312333 |===================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1433 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 358 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1422 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 177 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 377 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 3014 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4044 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 32320 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1379 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 10700 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1435 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 1440 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1216 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 311333 |===================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1434 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 358 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1427 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 178 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 4018 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 32180 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1376 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 11033 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1472 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 11767 |====================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid MB/s > Higher Is Better fiona raid sync . 1492 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/raid IOPS > Higher Is Better fiona raid sync . 11933 |======================================================