fsfiotest AMD EPYC 7401P 24-Core testing with a GIGABYTE MZ21-G20-00 v01000100 (F03d BIOS) and Gigabyte NVIDIA GeForce RTX 2080 Ti 11GB on CentOS Linux 8 via the Phoronix Test Suite. fiona direct buffered: Processor: AMD EPYC 7401P 24-Core @ 2.00GHz (24 Cores / 48 Threads), Motherboard: GIGABYTE MZ21-G20-00 v01000100 (F03d BIOS), Chipset: AMD 17h, Memory: 8 x 16384 MB DDR4-2667MT/s Samsung M393A2G40EB2-CTD, Disk: 2 x 3841GB Micron_9200_MTFDHAL3T8TCT + 8GB Flash Disk + 2 x 480GB Micron_5200_MTFD, Graphics: Gigabyte NVIDIA GeForce RTX 2080 Ti 11GB, Audio: NVIDIA TU102 HD Audio, Monitor: Smart Cable, Network: 2 x Mellanox MT27710 + 2 x Mellanox MT27800 OS: CentOS Linux 8, Kernel: 4.18.0-80.11.2.el8_0.x86_64 (x86_64), Display Server: X Server 1.20.3, Display Driver: NVIDIA 440.33.01, Compiler: GCC 8.3.1 20190507 + CUDA 10.2, File-System: xfs, Screen Resolution: 1024x768 Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 366 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 363 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 372 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 182 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 31.9 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 8165 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 389 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 94 |=================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 53.8 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 6889 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 414 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 48 |=================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 64.8 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 4145 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 94.3 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 3015 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 144 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 2307 |================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 394 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 390 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 398 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 195 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 312 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 79933 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 409 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 99 |=================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 347 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 44367 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 443 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 52 |=================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 190 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 1521 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 252 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 1004 |================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 308 |================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 612 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 395 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 25233 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 375 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 11667 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 382 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 6107 |================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 384 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 3071 |================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 387 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 1546 |================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fiona direct buffered . 389 |================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fiona direct buffered . 774 |==================================================