Ice Ice Lake Intel Core i7-1065G7 testing with a Dell 06CDVY (1.0.9 BIOS) and Intel Iris Plus G7 3GB on Ubuntu 19.10 via the Phoronix Test Suite. KBG40ZPZ512G NVMe TOSHIBA: Processor: Intel Core i7-1065G7 @ 3.90GHz (4 Cores / 8 Threads), Motherboard: Dell 06CDVY (1.0.9 BIOS), Chipset: Intel Device 34ef, Memory: 16GB, Disk: KBG40ZPZ512G NVMe TOSHIBA 512GB, Graphics: Intel Iris Plus G7 3GB (1100MHz), Audio: Realtek ALC289, Network: Intel Killer Wi-Fi 6 AX1650i 160MHz OS: Ubuntu 19.10, Kernel: 5.3.0-46-generic (x86_64), Desktop: GNOME Shell 3.34.3, Display Server: X Server 1.20.8, Display Driver: modesetting 1.20.8, OpenGL: 4.6 Mesa 20.1.0-devel (git-95f555a 2020-04-21 eoan-oibaf-ppa), OpenCL: OpenCL 2.1, Compiler: GCC 9.2.1 20191008, File-System: ext4, Screen Resolution: 1920x1200 Intel Core i7-1065G7: Processor: Intel Core i7-1065G7 @ 3.90GHz (4 Cores / 8 Threads), Motherboard: Dell 06CDVY (1.0.9 BIOS), Chipset: Intel Device 34ef, Memory: 16GB, Disk: KBG40ZPZ512G NVMe TOSHIBA 512GB, Graphics: Intel Iris Plus G7 3GB (1100MHz), Audio: Realtek ALC289, Network: Intel Killer Wi-Fi 6 AX1650i 160MHz OS: Ubuntu 19.10, Kernel: 5.3.0-46-generic (x86_64), Desktop: GNOME Shell 3.34.3, Display Server: X Server 1.20.8, Display Driver: modesetting 1.20.8, OpenGL: 4.6 Mesa 20.1.0-devel (git-95f555a 2020-04-21 eoan-oibaf-ppa), OpenCL: OpenCL 2.1, Compiler: GCC 9.2.1 20191008, File-System: ext4, Screen Resolution: 1920x1200 Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1509 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1710 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 855 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 61.2 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15667 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1838 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 459 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 111 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 14267 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1937 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 242 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 187 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11333 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 284 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9089 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 555 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8875 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1456 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1438 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1713 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 856 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 61.6 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15800 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1846 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 461 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 111 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 14300 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1906 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 238 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 843 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 842 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 835 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 417 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.6 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15500 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 794 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 198 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 108 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13800 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 785 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 97 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1109 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1105 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1092 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 546 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 212 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 54167 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1053 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 263 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 360 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 46100 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1032 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 128 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 829 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6630 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1079 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4317 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1106 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2211 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 188 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12033 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 285 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9132 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 554 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8858 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 174 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11100 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 202 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6448 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 361 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5782 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 838 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 844 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 838 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 418 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.6 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15500 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 799 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 199 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 108 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13833 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 787 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 98 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 613 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 39093 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 879 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 28000 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1064 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16887 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1022 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1030 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1016 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 508 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 218 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55900 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1043 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 260 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 376 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 48153 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 124 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 657 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 654 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 653 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 326 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 650 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 166533 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 677 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 169 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 665 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 85107 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 628 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 78 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 855 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6840 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1074 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4295 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1117 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2234 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 540 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4321 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 647 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2589 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 726 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1450 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 173 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11100 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 203 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6510 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 354 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5668 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 980 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7843 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 980 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3921 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 996 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1991 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 620 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 39683 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 862 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 27587 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1031 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16507 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 726 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 46433 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 722 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23107 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 725 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11600 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 658 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 641 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 659 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 329 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 636 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 162733 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 662 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 165 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 686 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 87747 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 666 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2226 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2222 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2236 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1114 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1304 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 334000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2245 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 557 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1881 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 241000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2258 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 531 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4253 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 648 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2591 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 732 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1463 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1043 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8345 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1019 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4077 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 950 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1899 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 730 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5841 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 715 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2861 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 705 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1410 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 714 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 45633 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 719 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23008 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 791 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12667 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1452 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1474 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1682 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 840 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 106 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 27100 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1842 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 460 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 149 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 19100 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1898 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 237 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1963 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 126000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1881 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60167 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1999 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 31000 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2225 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2222 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2238 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1116 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1302 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 333000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2248 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 558 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1899 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 243000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2261 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2107 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2103 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2173 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1083 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 672 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 172000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2436 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 605 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1131 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 145000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3242 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 402 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2222 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2218 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2238 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1115 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1304 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 334000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2245 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 558 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1899 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 243000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2261 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1393 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1389 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1674 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 833 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 61.4 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1852 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 460 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 111 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 14167 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1921 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 237 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 996 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 992 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 587 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 569 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 638 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 163200 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 657 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 309 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 634 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 81133 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 658 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 213 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 740 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5916 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 687 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2747 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 739 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1477 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 191 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12233 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 295 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9430 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 556 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8894 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1495 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1495 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1719 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 859 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 106 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 27100 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1855 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 463 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 150 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 19167 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1950 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 243 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1743 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1743 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1796 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 898 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1654 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 423333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1889 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 472 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1650 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 211333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1955 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 244 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 860 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 796 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 986 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 492 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 222 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 56700 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1037 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 259 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 400 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 50900 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1050 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 131 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2147 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17200 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2188 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8748 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2205 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4406 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1946 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 125000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1871 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 59900 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1995 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 31600 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1563 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 100067 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1703 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 54467 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1829 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 29267 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2101 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2098 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2168 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1080 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 672 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 172000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2432 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 604 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1130 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 144667 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3249 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 402 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1946 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 124667 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1872 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 59900 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1998 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 31000 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2220 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2216 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2232 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1113 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1301 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 333000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2245 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 558 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1882 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 241000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2260 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 845 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 842 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 842 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 417 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.3 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15400 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 809 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 199 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 107 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 811 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 98 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 187 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11300 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 284 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9094 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 557 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8905 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1430 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1427 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1700 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 846 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 61.4 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1870 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 464 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 109 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13667 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1923 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 237 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 840 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 836 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 857 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 425 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.3 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15433 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 822 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 202 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 107 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 850 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 103 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1001 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 64073 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1020 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32640 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1082 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17300 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1015 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1011 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 387 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 389 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 653 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 167333 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 575 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 266 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 657 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83833 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 679 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 189 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 664 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 661 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 672 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 332 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 609 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 155933 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 760 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 186 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 688 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 88033 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 846 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 102 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1067 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1063 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1076 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 534 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 662 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 169667 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1061 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 261 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 642 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 82127 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1034 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 126 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1067 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1063 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1046 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 519 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 218 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55767 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1039 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 256 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 383 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 49067 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1052 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 128 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 800 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6398 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1061 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4245 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1113 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2226 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 188 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12067 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 285 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9107 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 556 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8896 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1620 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 103667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1680 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 53767 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1680 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 26867 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1751 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1745 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1798 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 898 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1699 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 434667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1907 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 476 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1618 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 207000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1960 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 244 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 645 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 41293 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 937 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 30144 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1068 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17108 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 996 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 995 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 970 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 485 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 217 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55400 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 967 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 241 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 378 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 48267 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 961 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 120 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 695 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 693 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 740 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 370 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 679 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 173867 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 735 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 183 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 727 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 92920 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 719 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 89 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2134 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17100 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2176 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8701 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2195 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4386 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1958 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2009 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8033 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2050 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4096 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1514 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 96900 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1689 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 54000 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1803 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 28800 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2133 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17100 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2175 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8695 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2195 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4386 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1902 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 122000 |=========================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1853 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 59267 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1969 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 31500 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 167 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 10700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 226 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7218 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 351 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5608 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 844 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 840 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 840 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 416 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.2 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15400 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 804 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 197 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 108 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13800 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 816 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 98 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 972 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7773 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1063 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4248 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1142 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2280 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 189 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12100 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 301 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9609 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 556 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8903 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 171 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 10300 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 244 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7789 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 366 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5847 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 838 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 834 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 851 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 422 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60.3 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15400 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 822 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 202 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 107 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13700 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 843 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 102 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 985 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7878 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1035 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4135 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 969 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1934 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 985 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 63025 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 966 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 30985 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 974 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15567 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 665 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 42483 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 703 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 22433 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 714 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11225 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 678 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 674 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 700 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 346 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 592 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 151467 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 737 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 181 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 663 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 84800 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 799 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 96 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 900 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 57347 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 910 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 29100 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 954 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15267 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 994 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 990 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 961 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 477 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 635 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 162600 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 986 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 243 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 616 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 78858 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1048 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 127 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 701 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 697 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 691 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 342 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 635 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 162667 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 697 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 171 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 667 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 85267 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 688 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 82 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 592 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 37883 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 913 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 29160 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1035 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16547 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1031 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1028 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1025 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 509 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 214 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 54813 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1072 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 264 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 372 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 47480 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1032 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 125 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 729 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 726 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 725 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 359 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 632 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 161583 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 753 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 185 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 692 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 88480 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 840 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 101 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1002 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8013 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1165 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4658 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1118 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2235 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1623 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12000 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1620 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6478 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1635 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3268 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1609 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 103000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1618 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 51767 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1622 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 25600 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1080 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8639 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1092 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4369 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1031 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2061 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 650 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 41620 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 945 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 30412 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1136 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 18100 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 762 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 48773 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 732 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23413 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 746 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11850 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 753 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 726 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 753 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 376 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 690 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 176400 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 744 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 185 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 710 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 90767 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 713 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 89 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2006 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16050 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2053 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8208 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2099 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4194 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2197 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17600 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2235 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8935 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2251 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4499 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 533 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4262 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 673 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2687 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 739 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1475 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 166 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 10600 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 205 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6571 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 350 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5590 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1002 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8012 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1201 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4801 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1166 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2328 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 557 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4452 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 684 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2733 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 742 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1479 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 170 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 10900 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 233 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7445 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 358 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5732 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 915 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7316 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 954 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3813 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 959 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1914 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 676 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5402 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 699 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2790 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 716 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1429 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 687 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 43993 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 702 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 22467 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 730 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11673 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1010 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8080 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1046 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4180 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 997 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1991 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 869 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55567 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1002 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32060 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 951 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15233 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 685 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 43853 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 709 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 22592 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 723 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11558 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 666 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 662 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 686 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 340 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 615 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 157400 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 688 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 168 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 655 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83840 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 687 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 82 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1006 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8046 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1037 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4144 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1013 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2023 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 609 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 38893 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 875 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 27993 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1143 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 18267 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 718 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 45900 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 737 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23560 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 725 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11593 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 740 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 737 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 778 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 385 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 654 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 167467 |=========================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 761 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 187 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 680 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 87020 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 835 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 101 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2244 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2240 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1120 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1446 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 370000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2253 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 560 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2079 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 266000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2265 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1569 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12567 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1571 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6282 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1608 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3216 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1112 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8892 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1055 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4218 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 983 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1966 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 737 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5896 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 730 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2919 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 742 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1484 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 739 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 47307 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 747 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23813 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 756 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11767 |============================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 527 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4212 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 651 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2602 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 728 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1454 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 537 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4290 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 653 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2608 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 727 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1450 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 719 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5751 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 702 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2806 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 697 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1391 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 978 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7817 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1068 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4269 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 985 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1966 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 756 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6045 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 685 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2735 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 699 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1395 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 706 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 45160 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 754 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 24100 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 720 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11500 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1070 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8559 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1074 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4291 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1078 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2152 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 741 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5926 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 727 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2905 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 721 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1439 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 727 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 46373 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 717 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 22933 |============================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 740 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11575 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 144000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 71900 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 35600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2244 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1120 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1450 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 371000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2254 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 560 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2080 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 266000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2262 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2094 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2090 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2144 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1068 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1778 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 455333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2374 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 590 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1965 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 251667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3007 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 372 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2239 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2235 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1120 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1483 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 379333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2253 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 560 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2080 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 266000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2265 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1403 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1399 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1685 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 839 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 105 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 26867 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1833 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 454 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 148 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 18333 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1912 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 235 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 985 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 982 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 394 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 395 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 666 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 170400 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 779 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 360 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 653 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83600 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 713 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 203 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 753 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6020 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 720 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2879 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 749 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1497 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 709 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5671 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 690 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2755 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 689 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1375 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 731 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5845 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 697 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2782 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 710 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1416 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17000 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8985 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2248 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4491 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 144000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 71900 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 35300 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2044 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 131000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2044 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 65400 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2049 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32800 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2095 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2092 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2140 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1066 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1776 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 454667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2372 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 590 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1963 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 251000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3010 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 373 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 144000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 71900 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 35600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2244 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2248 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1120 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1481 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 379000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2254 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 560 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2079 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 266000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2263 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 279 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1733 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1730 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1800 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 896 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1603 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 410000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1894 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 470 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1602 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 205000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1971 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 243 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 187 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11333 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 284 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9071 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 557 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8902 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1392 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1388 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1685 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 839 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 105 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 26633 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1841 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 457 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 148 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 18300 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1910 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 235 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1740 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1737 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1795 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 894 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1703 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 436000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1938 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 481 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1626 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 208000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2067 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 255 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 952 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 61156 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 979 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 31425 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 993 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 15760 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 977 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 973 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 390 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 392 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 655 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 167667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 632 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 299 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 656 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83860 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 639 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 188 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 712 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 709 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 731 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 362 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 658 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 168000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 788 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 193 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 672 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 85960 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 844 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 102 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1017 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1013 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 993 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 493 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 664 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 170067 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1038 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 256 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 652 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 83100 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 983 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 119 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1051 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1048 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 999 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 496 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 218 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55733 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 983 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 242 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 378 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 48133 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1050 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 128 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17000 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8981 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2247 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4490 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2050 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16400 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2053 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8206 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2074 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4143 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2040 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 131000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2041 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 65300 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2045 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32700 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17000 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2243 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8970 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4488 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 144000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 71867 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 35900 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1629 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 104000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1649 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 52800 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1662 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 26600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1747 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1743 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1793 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 893 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1596 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 408667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1900 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 471 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1590 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 203333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1970 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 242 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 984 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7867 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1140 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4558 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1152 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2300 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 187 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11300 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 284 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 9091 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 556 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8901 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1536 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 97967 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1592 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 50933 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1696 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 26800 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1751 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1747 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1807 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 900 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1692 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 433333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1938 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 481 |============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1613 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 206333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2062 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 254 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 980 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7833 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1023 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4089 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 992 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1981 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1030 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 65900 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1015 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32482 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1017 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16267 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 700 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 44820 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 762 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23733 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 748 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11967 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 681 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 677 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 749 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 371 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 643 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 164750 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 765 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 188 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 692 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 88233 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 841 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 102 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 974 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 62333 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1029 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32860 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1007 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16041 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1050 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1047 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1003 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 498 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 659 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 169000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 981 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 242 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 639 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 81617 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1022 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 124 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 719 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 716 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 709 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 351 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 631 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 161533 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 718 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 176 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 694 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 88767 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 733 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 88 |=============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 649 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 41533 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 925 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 29467 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1073 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17160 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 984 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 980 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 978 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 485 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 213 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 54227 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1005 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 248 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 386 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 49367 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1021 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 124 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 744 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 741 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 768 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 381 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 715 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 182667 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 790 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 194 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 719 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 91700 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 809 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 98 |=============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2047 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16400 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2049 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8192 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2064 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4125 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2245 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17000 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8981 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2246 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4489 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1770 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 14133 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1779 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7112 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1669 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3334 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1716 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 110000 |=========================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1745 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 55833 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1768 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 28300 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1009 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8067 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1153 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4609 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1154 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2305 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1780 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 14233 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1794 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7172 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1718 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3432 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1563 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 99867 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1644 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 52600 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1777 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 28400 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1020 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8156 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 995 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3975 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1003 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2003 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 743 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5941 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 729 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2912 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 688 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1372 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 690 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 44167 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 708 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 22658 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 715 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11435 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 896 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 7167 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1008 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4028 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 937 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1871 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 943 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 60500 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1004 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 32007 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1015 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 16159 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 715 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 45753 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 744 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23717 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 735 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11720 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 711 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 708 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 733 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 363 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 646 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 165333 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 718 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 176 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 677 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 86675 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 725 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 87 |=============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1044 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 8348 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1077 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 4305 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1000 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1997 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 631 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 40280 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 905 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 28775 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1119 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 17827 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 733 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 46867 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 724 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 23040 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 742 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 11867 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 736 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 732 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 764 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 378 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 672 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 172067 |=========================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 799 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 196 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 720 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 92133 |============================================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 819 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 99 |=============================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1600 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 12800 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1601 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6401 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1612 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3221 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1656 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 13233 |============================================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1664 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 6652 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1672 |============================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 3340 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 742 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 5933 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 724 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 2893 |============================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 723 |============================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better KBG40ZPZ512G NVMe TOSHIBA . 1443 |============================================= C-Blosc 2.0 Beta 5 Compressor: blosclz MB/s > Higher Is Better Intel Core i7-1065G7 . 9101.7 |================================================ SVT-AV1 0.8 Encoder Mode: Enc Mode 0 - Input: 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 0.064 |================================================= SVT-AV1 0.8 Encoder Mode: Enc Mode 4 - Input: 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 1.030 |================================================= SVT-AV1 0.8 Encoder Mode: Enc Mode 8 - Input: 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 9.215 |================================================= SVT-VP9 0.1 Tuning: VMAF Optimized - Input: Bosphorus 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 70.05 |================================================= SVT-VP9 0.1 Tuning: PSNR/SSIM Optimized - Input: Bosphorus 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 70.05 |================================================= SVT-VP9 0.1 Tuning: Visual Quality Optimized - Input: Bosphorus 1080p Frames Per Second > Higher Is Better Intel Core i7-1065G7 . 51.22 |================================================= Timed Linux Kernel Compilation 5.4 Time To Compile Seconds < Lower Is Better Intel Core i7-1065G7 . 243.32 |================================================