fiolog Intel Core i5-8265U testing on Microsoft Windows 10 Enterprise LTSC Build 17763 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 2004095-AS-FIOLOG87653 Oracle VirtIO Disk Processor: Intel Core i5-8265U @ 1.80GHz (2 Cores), Memory: 4193MB, Disk: 30GB Oracle VirtIO Disk + 50GB Oracle VirtIO Disk, Graphics: Intel UHD 620 1GB, Network: Oracle VirtIO
OS: Microsoft Windows 10 Enterprise LTSC Build 17763, Kernel: 10.0 (x86_64), Display Driver: 26.20.100.7323, File-System: NTFS, Screen Resolution: 1920x1080
Security Notes: __user pointer sanitization: Disabled + IBPB: Always + IBRS: Enabled + STIBP: Enabled
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 40 80 120 160 200 SE +/- 5.29, N = 15 204
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 60 120 180 240 300 SE +/- 16.48, N = 12 266
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 8.19, N = 12 132
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 1.03, N = 15 6.69
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 265.48, N = 15 1698
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 80 160 240 320 400 SE +/- 5.13, N = 15 373
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 1.31, N = 15 93
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1.197 2.394 3.591 4.788 5.985 SE +/- 0.88, N = 12 5.32
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 140 280 420 560 700 SE +/- 113.78, N = 12 670
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 8.00, N = 15 399
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 0.98, N = 15 49
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 16.58, N = 15 99.50
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1400 2800 4200 5600 7000 SE +/- 1061.40, N = 15 6365
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 17.68, N = 15 432
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3K 6K 9K 12K 15K SE +/- 564.40, N = 15 13840
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 130 260 390 520 650 SE +/- 37.20, N = 12 610
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2K 4K 6K 8K 10K SE +/- 599.45, N = 12 9772
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 15.76, N = 15 974
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 15.72, N = 15 973
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 1013
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 110 220 330 440 550 506
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4 8 12 16 20 SE +/- 2.35, N = 15 13.73
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 800 1600 2400 3200 4000 SE +/- 604.11, N = 15 3505
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 11.25, N = 12 907
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 2.82, N = 12 226
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 11.27, N = 12 88.05
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2K 4K 6K 8K 10K SE +/- 1445.70, N = 12 11275
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 846
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.59, N = 15 48.64
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.56, N = 15 48
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.37, N = 15 49.49
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 0.71, N = 15 24
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 0.3173 0.6346 0.9519 1.2692 1.5865 SE +/- 0.10, N = 15 1.41
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 80 160 240 320 400 SE +/- 25.26, N = 15 351
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 3.66, N = 12 42.60
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 3 6 9 12 15 SE +/- 0.23, N = 11 11
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 0.8708 1.7416 2.6124 3.4832 4.354 SE +/- 0.36, N = 15 3.87
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 100 200 300 400 500 SE +/- 45.60, N = 15 483
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.13, N = 12 45.38
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 1.125 2.25 3.375 4.5 5.625 5
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.65, N = 3 877
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1500 3000 4500 6000 7500 SE +/- 21.31, N = 3 7014
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 4.36, N = 3 944
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 800 1600 2400 3200 4000 SE +/- 17.40, N = 3 3776
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 1.20, N = 3 401
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 5K 10K 15K 20K 25K SE +/- 88.19, N = 3 25633
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 130 260 390 520 650 SE +/- 3.18, N = 3 587
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4K 8K 12K 16K 20K SE +/- 233.33, N = 3 18467
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 160 320 480 640 800 SE +/- 2.96, N = 3 759
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3K 6K 9K 12K 15K SE +/- 33.33, N = 3 12167
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 0.38, N = 15 8.64
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 120 240 360 480 600 SE +/- 24.64, N = 15 542
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4 8 12 16 20 SE +/- 0.63, N = 15 15.49
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 110 220 330 440 550 SE +/- 20.31, N = 15 497
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 1.24, N = 15 25.63
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 20.00, N = 15 411
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.59, N = 15 44.95
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.54, N = 15 44
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.47, N = 15 42.13
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 5 10 15 20 25 SE +/- 0.74, N = 15 21
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 0.4208 0.8416 1.2624 1.6832 2.104 SE +/- 0.15, N = 15 1.87
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 100 200 300 400 500 SE +/- 37.89, N = 15 467
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 3.48, N = 12 42.74
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 3 6 9 12 15 SE +/- 0.85, N = 12 10
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1.0755 2.151 3.2265 4.302 5.3775 SE +/- 0.36, N = 13 4.78
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 130 260 390 520 650 SE +/- 45.29, N = 13 597
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 2.12, N = 12 43.00
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 1.125 2.25 3.375 4.5 5.625 SE +/- 0.28, N = 12 5
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.33, N = 3 873
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1500 3000 4500 6000 7500 SE +/- 18.41, N = 3 6988
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 1.45, N = 3 954
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 800 1600 2400 3200 4000 SE +/- 6.36, N = 3 3818
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 9 18 27 36 45 SE +/- 1.98, N = 12 39.67
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 70 140 210 280 350 SE +/- 15.83, N = 12 317
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 8 16 24 32 40 SE +/- 3.00, N = 12 36.61
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 12.04, N = 12 146
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 0.37, N = 15 8.72
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 120 240 360 480 600 SE +/- 23.12, N = 15 545
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4 8 12 16 20 SE +/- 0.66, N = 12 14.86
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 100 200 300 400 500 SE +/- 20.16, N = 12 478
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 0.89, N = 12 27.09
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 14.17, N = 12 433
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 0.96, N = 15 42.87
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 70 140 210 280 350 SE +/- 7.32, N = 15 343
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 0.81, N = 15 50.69
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 40 80 120 160 200 SE +/- 3.26, N = 15 203
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 4.81, N = 3 1035
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 4.81, N = 3 1034
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 0.67, N = 3 1031
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 110 220 330 440 550 SE +/- 0.67, N = 3 515
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 60 120 180 240 300 SE +/- 0.67, N = 3 259
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 14K 28K 42K 56K 70K SE +/- 458.26, N = 3 65900
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.73, N = 3 924
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 230
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 8.49, N = 12 399
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11K 22K 33K 44K 55K SE +/- 1088.52, N = 12 51125
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 3.61, N = 3 828
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 0.58, N = 3 103
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 130 260 390 520 650 SE +/- 4.00, N = 3 591
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 8K 16K 24K 32K 40K SE +/- 284.80, N = 3 37833
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 160 320 480 640 800 SE +/- 13.11, N = 15 744
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 5K 10K 15K 20K 25K SE +/- 420.08, N = 15 23813
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.52, N = 3 917
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3K 6K 9K 12K 15K SE +/- 33.33, N = 3 14667
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 7.06, N = 3 1035
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 7.06, N = 3 1035
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 1.45, N = 3 1029
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 110 220 330 440 550 SE +/- 0.58, N = 3 514
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 60 120 180 240 300 SE +/- 0.33, N = 3 257
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 14K 28K 42K 56K 70K SE +/- 88.19, N = 3 65833
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.73, N = 3 906
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 0.58, N = 3 226
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 6.43, N = 15 401
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11K 22K 33K 44K 55K SE +/- 825.07, N = 15 51240
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.33, N = 3 832
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 103
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 13 26 39 52 65 SE +/- 0.59, N = 15 56.10
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 13 26 39 52 65 SE +/- 0.57, N = 15 56
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 0.64, N = 15 53.48
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 0.35, N = 15 26
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 0.23, N = 3 53.97
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3K 6K 9K 12K 15K SE +/- 66.67, N = 3 13833
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 1.14, N = 15 52.02
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.92, N = 12 45.85
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1300 2600 3900 5200 6500 SE +/- 245.60, N = 12 5869
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 2.42, N = 15 44.23
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 1.125 2.25 3.375 4.5 5.625 SE +/- 0.33, N = 15 5
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 10.33, N = 3 1455
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 10.02, N = 3 1451
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 6.94, N = 3 1541
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 170 340 510 680 850 SE +/- 3.48, N = 3 767
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 5 10 15 20 25 SE +/- 0.22, N = 8 22.24
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1200 2400 3600 4800 6000 SE +/- 38.43, N = 8 5722
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 12.17, N = 3 1774
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 100 200 300 400 500 SE +/- 3.28, N = 3 440
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 0.52, N = 3 45.13
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1200 2400 3600 4800 6000 SE +/- 64.59, N = 3 5774
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 14.71, N = 3 1875
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 1.67, N = 3 231
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 10.66, N = 14 946
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1600 3200 4800 6400 8000 SE +/- 85.28, N = 14 7566
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 4.10, N = 3 997
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 900 1800 2700 3600 4500 SE +/- 16.58, N = 3 3989
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 130 260 390 520 650 SE +/- 4.70, N = 3 591
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 8K 16K 24K 32K 40K SE +/- 305.51, N = 3 37800
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 160 320 480 640 800 SE +/- 5.78, N = 3 762
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 5K 10K 15K 20K 25K SE +/- 185.59, N = 3 24367
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 11.02, N = 3 914
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3K 6K 9K 12K 15K SE +/- 176.38, N = 3 14633
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.48, N = 15 49.41
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 700 1400 2100 2800 3500 SE +/- 94.93, N = 15 3162
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 0.29, N = 3 47.30
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 8.67, N = 3 1513
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 1.75, N = 15 52.35
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 27.84, N = 15 838
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 0.80, N = 15 49.87
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 49
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.47, N = 13 46.88
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 0.74, N = 13 23
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 9 18 27 36 45 SE +/- 3.43, N = 12 39.70
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2K 4K 6K 8K 10K SE +/- 868.88, N = 12 10090
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 7 14 21 28 35 SE +/- 2.97, N = 12 31.48
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 0.75, N = 12 8
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 10 20 30 40 50 SE +/- 1.88, N = 12 43.43
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1200 2400 3600 4800 6000 SE +/- 240.72, N = 12 5569
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 8 16 24 32 40 SE +/- 3.11, N = 12 35.48
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 0.9 1.8 2.7 3.6 4.5 SE +/- 0.40, N = 12 4
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 1.39, N = 3 85.00
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1200 2400 3600 4800 6000 SE +/- 89.33, N = 3 5436
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 1.20, N = 3 157
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1100 2200 3300 4400 5500 SE +/- 42.27, N = 3 5016
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 70 140 210 280 350 299
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1000 2000 3000 4000 5000 SE +/- 15.52, N = 3 4788
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 18.23, N = 4 1462
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 18.36, N = 4 1459
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 17.46, N = 3 1589
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 8.84, N = 3 791
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 5 10 15 20 25 SE +/- 0.20, N = 9 20.22
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1100 2200 3300 4400 5500 SE +/- 48.89, N = 9 5177
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 7.21, N = 3 1764
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 1.86, N = 3 437
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 9 18 27 36 45 SE +/- 0.50, N = 3 41.47
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1100 2200 3300 4400 5500 SE +/- 64.05, N = 3 5305
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 10.48, N = 3 1869
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 1.53, N = 3 230
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 160 320 480 640 800 SE +/- 8.77, N = 15 747
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 160 320 480 640 800 SE +/- 8.81, N = 15 744
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.33, N = 3 796
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 1.33, N = 3 394
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 0.10, N = 3 78.00
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4K 8K 12K 16K 20K SE +/- 300.00, N = 3 19300
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 4.67, N = 3 809
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 40 80 120 160 200 SE +/- 1.33, N = 3 198
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 0.67, N = 3 141
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 4K 8K 12K 16K 20K SE +/- 66.67, N = 3 17967
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 8.80, N = 15 784
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 20 40 60 80 100 SE +/- 1.08, N = 15 94
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 15 30 45 60 75 SE +/- 6.93, N = 12 67.95
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory Oracle VirtIO Disk 15 30 45 60 75 SE +/- 6.84, N = 12 65
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 117
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 55
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 0.01, N = 3 7.22
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory Oracle VirtIO Disk 400 800 1200 1600 2000 SE +/- 2.67, N = 3 1802
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 1.15, N = 3 116
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory Oracle VirtIO Disk 6 12 18 24 30 SE +/- 0.33, N = 3 26
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 3 6 9 12 15 SE +/- 0.00, N = 3 12.10
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 2.85, N = 3 1547
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 16 32 48 64 80 SE +/- 8.88, N = 12 69.90
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory Oracle VirtIO Disk 2 4 6 8 10 SE +/- 1.04, N = 12 6
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 15.55, N = 12 945
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 1600 3200 4800 6400 8000 SE +/- 123.99, N = 12 7562
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 200 400 600 800 1000 SE +/- 2.08, N = 3 995
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 900 1800 2700 3600 4500 SE +/- 8.19, N = 3 3980
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 13 26 39 52 65 SE +/- 0.81, N = 3 58.60
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory Oracle VirtIO Disk 100 200 300 400 500 SE +/- 6.44, N = 3 469
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 2.09, N = 15 51.24
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory Oracle VirtIO Disk 40 80 120 160 200 SE +/- 8.28, N = 15 205
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 1.56, N = 15 53.91
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory Oracle VirtIO Disk 700 1400 2100 2800 3500 SE +/- 100.29, N = 15 3450
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 11 22 33 44 55 SE +/- 1.81, N = 12 50.15
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 57.10, N = 12 1607
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 7 14 21 28 35 SE +/- 0.35, N = 3 28.90
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 12 24 36 48 60 SE +/- 0.67, N = 3 54
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 8 16 24 32 40 SE +/- 2.92, N = 12 35.83
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Random Write - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 15 30 45 60 75 SE +/- 5.92, N = 12 69
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 14.87, N = 7 1417
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 600 1200 1800 2400 3000 SE +/- 29.73, N = 7 2832
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 300 600 900 1200 1500 SE +/- 6.33, N = 3 1432
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 600 1200 1800 2400 3000 SE +/- 12.57, N = 3 2860
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 1.76, N = 3 206
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 3.84, N = 3 409
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 15 30 45 60 75 SE +/- 0.09, N = 3 66.43
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 129
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 50 100 150 200 250 SE +/- 2.03, N = 15 212
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Read - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 90 180 270 360 450 SE +/- 4.02, N = 15 421
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 13 26 39 52 65 SE +/- 1.82, N = 15 59.10
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 30 60 90 120 150 SE +/- 3.66, N = 15 115
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 7 14 21 28 35 SE +/- 2.65, N = 12 29.68
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 13 26 39 52 65 SE +/- 5.25, N = 12 56
OpenBenchmarking.org MB/s, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 8 16 24 32 40 SE +/- 2.22, N = 15 35.99
OpenBenchmarking.org IOPS, More Is Better Flexible IO Tester 3.18 Type: Sequential Write - Engine: Windows AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory Oracle VirtIO Disk 15 30 45 60 75 SE +/- 4.46, N = 15 69
Oracle VirtIO Disk Processor: Intel Core i5-8265U @ 1.80GHz (2 Cores), Memory: 4193MB, Disk: 30GB Oracle VirtIO Disk + 50GB Oracle VirtIO Disk, Graphics: Intel UHD 620 1GB, Network: Oracle VirtIO
OS: Microsoft Windows 10 Enterprise LTSC Build 17763, Kernel: 10.0 (x86_64), Display Driver: 26.20.100.7323, File-System: NTFS, Screen Resolution: 1920x1080
Security Notes: __user pointer sanitization: Disabled + IBPB: Always + IBRS: Enabled + STIBP: Enabled
Testing initiated at 8 April 2020 09:56 by user ACRN.