fbsd12_zfs_ssd_ixsystems_disk2.out fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 fbsd12_zfs_ssd_ixsystems_disk2: Processor: Intel Xeon E5-2690 v2 @ 3.00GHz (40 Cores), Motherboard: iXsystems 06-Q115-1 0123456789, Chipset: Intel Xeon E7 v2/Xeon E5 v2/Core i7 DMI2, Memory: 393216MB, Disk: 22 x Samsung SSD 845D AX3Q + 2 x INTEL SSDSC2BA20 0110 + 2 x INTEL SSDSC2BB080G6 G2010130 + AHCI SGPIO Enclosure 1.00 0001, Graphics: Matrox MGA G200eW WPCM450 OS: FreeBSD, Kernel: 12.0-RELEASE-p13 (x86_64), Compiler: Clang 6.0.1 (SVN 335540), File-System: zfs fbsd12_zfs_less_tuning_ssd_ixsystems_disk3: Processor: Intel Xeon E5-2690 v2 @ 3.00GHz (40 Cores), Motherboard: iXsystems 06-Q115-1 0123456789, Chipset: Intel Xeon E7 v2/Xeon E5 v2/Core i7 DMI2, Memory: 393216MB, Disk: 22 x Samsung SSD 845D AX3Q + 2 x INTEL SSDSC2BA20 0110 + 2 x INTEL SSDSC2BB080G6 G2010130 + AHCI SGPIO Enclosure 1.00 0001, Graphics: Matrox MGA G200eW WPCM450 OS: FreeBSD, Kernel: 12.0-RELEASE-p13 (x86_64), Compiler: Clang 6.0.1 (SVN 335540), File-System: zfs Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5629 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5901 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2838 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2991 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 188000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 196333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1431 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1506 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162667 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 176000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 718 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 754 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 133667 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 137000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 99000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 101667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60533 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 60767 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5606 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5918 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2835 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3007 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 188667 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 199333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1430 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1509 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162667 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 174333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 719 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 756 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5610 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5925 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2856 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2997 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 189000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 197000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1432 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1513 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 163000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 170667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 721 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 757 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 152 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 166 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 88 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 83 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3982 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3559 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 42 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 42 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17987 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19047 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 21 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 36233 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36733 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19700 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20300 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10700 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 11067 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 131333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 134000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 98267 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 100167 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60400 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 60833 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 130333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 133667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 97533 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 101000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60033 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 61000 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5565 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5791 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2828 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2930 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 193000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1423 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1473 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 161000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 715 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 740 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10333 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10219 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4585 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4663 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1856 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1864 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 90 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 87 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3921 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3813 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 43 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 42 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17542 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18340 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 21 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 21 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 164 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 85 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 86 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3941 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3915 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 43 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 41 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17942 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18292 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 21 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 36233 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36533 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19767 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19933 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10700 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10900 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 36133 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36633 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19733 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10900 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 130000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 132000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 98633 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 98700 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 59833 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1418 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1439 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 696 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 691 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 345 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 343 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10366 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10569 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4655 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4661 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1840 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1901 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10156 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9917 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4580 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4774 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1871 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1852 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 87 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 89 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3732 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4017 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 43 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 42 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 18100 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18013 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 36533 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36500 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19900 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19600 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10800 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1428 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1363 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 692 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 686 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 344 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 344 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1418 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1394 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 723 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 699 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 356 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 335 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10422 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9934 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4639 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4649 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1880 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1791 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5662 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5721 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2860 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2888 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 262667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 256333 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1439 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1455 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 218333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 212000 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 722 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 727 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17640 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17307 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9057 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9062 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 187333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 187667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4501 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4484 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 187667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 185667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2230 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2238 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1441 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1412 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 727 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 694 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 361 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 350 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 157667 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 113667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 110000 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 65467 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 64400 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5591 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5671 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2825 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2855 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 258000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 255667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1426 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1434 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 215333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 211667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 713 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 724 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5590 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5684 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2842 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2872 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 262333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 253333 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1424 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1442 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 222000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 216667 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 718 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 725 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 61 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 61 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 100500 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 99433 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 31 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 29 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 89467 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 88167 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 184333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 183333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 182333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 182333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 178333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 179333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17453 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17433 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8987 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9078 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4495 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4521 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2228 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2251 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17033 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17673 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8900 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8905 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4371 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4432 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 187000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2132 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2148 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 80 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 85 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2691 |================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4474 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 44 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 40 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2292 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2676 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 18 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20 |============================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 36233 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 37067 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19733 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19667 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10733 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10767 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 161333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 111667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 110667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 64900 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 63933 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 161333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 159000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 112000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 110667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 65167 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 63967 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5602 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5596 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2834 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2828 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 257667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 260667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1425 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1423 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 219000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 213000 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 716 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 714 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30033 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 30433 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9036 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9020 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1893 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1940 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 62 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 100550 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 99825 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 30 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 87233 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 86867 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 14 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 61 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 59 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 98567 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 97700 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 29 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 88533 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 86567 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 158750 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 157333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 114467 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 38293 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 39175 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 188667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 182667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 184000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 176333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 179000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 185333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 180667 |========================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 176000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 176333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 18033 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17730 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8938 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9007 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186333 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4421 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4417 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 188000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 184000 |========================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2139 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2165 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2744 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3128 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2674 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2752 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1938 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1931 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 164 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 163 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 81 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 80 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2694 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2711 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 39 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 39 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2577 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2657 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 21 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 163 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 160 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 84 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 77 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2600 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2656 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 40 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 40 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2811 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2879 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 19 |============================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 37067 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36733 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20067 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20100 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10767 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10767 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 37000 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 37100 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20133 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20100 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10800 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 160667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 113667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 110667 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 64867 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 64167 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 962 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 940 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 481 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 471 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 254 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 237 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 29233 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 29453 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9375 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9198 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1920 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1912 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30045 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 29763 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9144 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9108 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1839 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1935 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 137 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |========================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 60 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 60 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 98567 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 101000 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 31 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 30 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 86933 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 86067 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15 |============================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 157000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158500 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 112667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 112860 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 39153 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 39713 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 153000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 114333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 112200 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 40833 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 37967 |========================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 184000 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 184000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 183667 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 178333 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1217 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1241 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 645 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 658 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 318 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 313 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2789 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2488 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2609 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2721 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1834 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1930 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2870 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2651 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2634 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2675 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2092 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1881 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 175 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 163 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 87 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 79 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2265 |========= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6894 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 40 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 40 |============================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2428 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2723 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 37167 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 36833 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19700 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20167 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10800 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10800 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 905 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 955 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 490 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 481 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 244 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 248 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1015 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 981 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 479 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 489 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 236 |==================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 338 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30500 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 30282 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9262 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 9210 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1903 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1950 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 160000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 155667 |========================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 115467 |========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 38507 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 40233 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1292 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1331 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 678 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 608 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 354 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 315 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1343 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1273 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 620 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 646 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 318 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 311 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2417 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2690 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2304 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2692 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2155 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1751 |======================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17447 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18133 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8944 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8989 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 190667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4492 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4514 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 187000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 189000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2235 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2247 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 957 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 995 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 515 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 494 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 254 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 243 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1341 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1345 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 645 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 643 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 325 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 311 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 187333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 187333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 179333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 181333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17867 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17814 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8990 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8937 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185750 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 187667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4467 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4458 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2226 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2226 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17567 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17700 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8841 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8876 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 190000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4373 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4385 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 188333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 189333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2140 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2132 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 65 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 64 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 22393 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 22750 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 39 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 31 |======================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 13575 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 14000 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 18 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 16 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 159667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 159833 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 112667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 108733 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 39367 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 40367 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 185000 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 189667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 184667 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 180333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 181333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 189000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 186333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 184333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 181333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17367 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17527 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 8888 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8924 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 184000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 186667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4379 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4381 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 187000 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 184333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2133 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2147 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 7865 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 8028 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3739 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3969 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1891 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1924 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 114 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 71 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 59 |========================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 22550 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 23633 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 31 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 34 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 14200 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 14593 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 18 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 116 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 116 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 59 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 66 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 22860 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 24120 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 31 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 35 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 13740 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15158 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 31 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17 |================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 157333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 105987 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 111333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 37775 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 37933 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 160267 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 159667 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 110333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 114000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 38047 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 37558 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 184333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 185000 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 189333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 189333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 180000 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 912 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 929 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 503 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 493 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 227 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 231 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 7644 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 7647 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3696 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3750 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1861 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1962 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 7513 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 7865 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3598 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3775 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1931 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1890 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 61 |============================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 61 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 23067 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 23853 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 30 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 32 |============================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 14560 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 13827 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17 |============================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 151333 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 160333 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 112333 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 107250 |========================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 38867 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 38807 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 969 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 919 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 487 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 465 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 236 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 228 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 950 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 935 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 468 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 463 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 233 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 244 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 7584 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 7685 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3849 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3863 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1917 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1904 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 931 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 940 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 492 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 482 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 253 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 236 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5630 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5902 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5676 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5984 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 735 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 767 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5725 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6024 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1270 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1376 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5747 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6038 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2084 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2144 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3094 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3182 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3785 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3819 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5606 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5919 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5670 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6016 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 737 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 778 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5723 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6038 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1270 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1363 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5755 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6049 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5610 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5925 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5714 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5996 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 738 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 771 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5731 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6054 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1276 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1331 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5775 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 6063 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 152.4 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167.0 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 176 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15.5 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 13.9 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 169 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 142 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 149 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 161 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 170 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4528 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4635 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4924 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5081 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5333 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5526 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2052 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2092 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3071 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3136 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3774 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3800 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2034 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2086 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3049 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3153 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3773 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3814 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5566 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5791 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5657 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5860 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 723 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 753 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5693 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5896 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1257 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1310 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5722 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5922 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 160 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 143 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 146 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 116.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 116.6 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 175 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15.3 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 14.9 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 170 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 137.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 144.0 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 175.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 164.8 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 174 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 15.4 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15.3 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 165 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 141.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 144.2 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 165 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4529 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4566 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4942 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4980 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5352 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5438 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4517 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4579 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4950 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5018 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5385 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5443 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2037 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2058 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3082 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3085 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3801 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3740 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 180 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 173 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 173 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 165 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 146 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 146 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 159 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 155 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 143 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 149 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 117.1 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 115.9 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 177 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 14.6 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 15.7 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 175 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 169 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 143 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 141 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 168 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4567 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4563 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4977 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4983 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5406 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5417 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 179 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 170 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 173 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 175 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 175 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 178 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 168 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 163 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 155 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 145 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 145 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 117.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 112.0 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5662 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5721 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5721 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5777 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1027 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1001 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5759 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5822 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1706 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1658 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5781 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5818 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 732 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 733 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1465 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1450 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 180 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 177 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 182 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 173 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 175 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2541 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2463 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3551 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3447 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4092 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4026 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5591 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5671 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5651 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5710 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1008 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 999 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5706 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5739 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1684 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1653 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5710 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5797 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5591 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5685 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5686 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5746 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1025 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 990 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5697 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5771 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1733 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1693 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5746 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5804 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 392 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 388 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 124 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 702 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 689 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2877 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2869 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5689 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5702 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 728 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 728 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1457 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1458 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 728 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 729 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1450 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1459 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 180 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 170 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 167 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 176 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10.61 |================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 17.58 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 190 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 173 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 17.9 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20.9 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 169 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 182 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4611 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4634 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5015 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4997 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5376 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5381 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2522 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2475 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3487 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3456 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4058 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3996 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2519 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2482 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3502 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3464 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4094 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3998 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5603 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5596 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5669 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5658 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1007 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1018 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5700 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5693 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1710 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1660 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5730 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5719 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 469 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 475 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 282 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 282 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 118 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121.5 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.2 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 125.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 392 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 390 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 681 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 679 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 385 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 383 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 691 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 677 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122.8 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123.0 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2892 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2947 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5717 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5749 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2899 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2895 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5800 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5638 |=========================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 724 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 727 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1468 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1438 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 42.9 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 48.9 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 83.6 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 86.1 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121.3 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120.9 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 167 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 170 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 166 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10.55 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10.69 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 168 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 20.1 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 20.8 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 199 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 176 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 167 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 164 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 160 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 10.31 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 10.53 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 173 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 22.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 22.5 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 177 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 181 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4631 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4632 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5021 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5025 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5382 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5384 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4625 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4637 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5029 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5031 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5388 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5396 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2510 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2475 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 3550 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 3457 |=========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4053 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4011 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.4 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118.0 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 127 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 462 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 461 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 293 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 288 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.4 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 474 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 465 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 286 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 285 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 137.6 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.0 |======================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 386 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 396 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 126 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 679 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 672 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121 |============================= Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2901 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2881 |============================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5753 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5738 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 153 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 156 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 165 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 161 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 43.5 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 38.9 |========================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 81.6 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 85.1 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121.0 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 44.8 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 41.4 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 82.4 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 83.7 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 131.1 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118.0 |======================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 178 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 181 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 164 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 9.073 |========= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 27.073 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 175 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 172 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 19.0 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 21.3 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 174 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 171 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 4641 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 4646 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5008 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5039 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5382 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5406 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 113.3 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 127 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119.9 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 118.2 |=================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 169.3 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 476 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 473 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 290 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 288 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122.0 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 170 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 153 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 179 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 159 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 168 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 160 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 155.9 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 162.0 |=========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 160 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 157 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 37.8 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 42.0 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 72.1 |======================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 84.2 |============================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 135.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 109.8 |====================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 727 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 746 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1461 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1476 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 125 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 129 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 127.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122.0 |========================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 168 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 169 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 162 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 162 |============================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 164 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2909 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2927 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5786 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5851 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 726 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 732 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1454 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1454 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 724 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 742 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1470 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1479 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 125 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 126 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 137 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 134 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 87.5 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 89.1 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 170 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 135 |======================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 106 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 112 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 172 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 155 |========================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2895 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2967 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5778 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5822 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2907 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2951 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5830 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5765 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 719 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 728 |============================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 1461 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 1440 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 125 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 116.9 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 118.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120.3 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 117.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 122.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 149.8 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 125.0 |======================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 87.9 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 92.5 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 138 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 151 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 111 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 114 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 164 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 167 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.7 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 124 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 138 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 89.3 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 94.5 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 135 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 154 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 107.9 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 275 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 158 |================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 2880 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 2892 |============================ Flexible IO Tester 3.18 Type: Sequential Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 5914 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 5914 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 114.4 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 116.5 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 126 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115.3 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117.1 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.6 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 115.6 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117.3 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 116.5 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 117 |============================ fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 123 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 113.0 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118.1 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 118 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 127.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120.4 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 129 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 130 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 90.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 93.3 |============================ Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 131.0 |========================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 142.5 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 113.8 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 109.1 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 150 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 159 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 122.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 115.4 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 123.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117.2 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 115.7 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119.2 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117.2 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 117.8 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 116.7 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 118.1 |========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 124.0 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 119 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 120 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 121 |============================= fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121 |============================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 120.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.2 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 116.9 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 117.8 |=========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 124.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 121.3 |========================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 128.0 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 119.8 |========================= Unpacking The Linux Kernel linux-4.15.tar.xz Seconds < Lower Is Better fbsd12_zfs_ssd_ixsystems_disk2 ............. 16.69 |=========================== fbsd12_zfs_less_tuning_ssd_ixsystems_disk3 . 16.58 |===========================