fiotest1 KVM testing on Ubuntu 18.04 via the Phoronix Test Suite. fio test prox6: Processor: Intel Xeon E3-12xx v2 @ 3.50GHz (6 Cores), Motherboard: QEMU Standard PC (i440FX + PIIX 1996) (rel-1.12.1-0-ga5cab58e9a3f-prebuilt.qemu.org BIOS), Chipset: Intel 440FX- 82441FX PMC, Memory: 4096MB, Disk: 34GB QEMU HDD, Graphics: EFI VGA, Network: Red Hat Virtio device OS: Ubuntu 18.04, Kernel: 4.15.0-38-generic (x86_64), Compiler: GCC 7.4.0, File-System: ext4, Screen Resolution: 800x600, System Layer: KVM Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 67117 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 524 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 429 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 53392 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 210 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52025 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1629 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42350 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 663 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11392 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 713 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11350 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 710 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43583 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1362 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23525 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 736 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51442 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1608 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 87642 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 343 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 203 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 206 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4876 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 18.98 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3827 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 59.75 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4803 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 18.78 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 201 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 204 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 398 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 201 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 831 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 209 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5847 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 731 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1489 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1493 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 410 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2706 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 678 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1876 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 118 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2754 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 689 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1842 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 115 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1124 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 564 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42100 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 659 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23311 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1457 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 521 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 525 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 822 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 206 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1002 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 503 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5891 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1474 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 6223 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 778 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 37057 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 579 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 64950 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 507 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1452 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5743 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1437 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 38075 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 595 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2099 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1052 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3882 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3885 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51933 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 406 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 15700 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 981 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 62367 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 244 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1073 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1076 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8530 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1067 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42033 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 657 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55867 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 218 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8075 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1010 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3796 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3799 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8145 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1019 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48233 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 379 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4190 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1048 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14867 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3716 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2080 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1042 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48467 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3029 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54100 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 845 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 56067 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 438 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4094 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1024 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 47967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2997 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51667 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1614 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55033 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 432 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 47267 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2953 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7538 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3771 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54167 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 847 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7779 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3892 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 50700 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 396 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14767 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3773 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 24500 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 766 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 50900 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 398 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7637 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3820 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42933 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1353 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27467 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3434 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 405 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 46933 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 2932 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1073 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1077 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55533 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 873 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51633 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1613 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1365 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 56700 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 445 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3768 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3772 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54833 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 216 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1052 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1056 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 55400 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 216 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5526 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1382 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 71967 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 281 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23200 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1449 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2891 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27400 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3468 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2987 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1495 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 43833 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1370 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 61067 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 239 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14700 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3675 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4323 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 33.80 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 54667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 855 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3844 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3848 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2995 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 93.70 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 3707 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 57.97 |======================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1584 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 199 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 49667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 781 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 16300 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1020 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4137 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1035 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23833 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 745 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1060 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1064 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 42633 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 666 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52867 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 516 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 520 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27867 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3485 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2132 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1068 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4233 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1059 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 5639 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1410 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11567 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1448 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 58533 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 457 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52400 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 205 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2819 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1411 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 71233 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 278 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 51667 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 202 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52400 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 207 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 4717 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 36.90 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1399 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1403 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2860 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 89.47 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2917 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1460 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 24800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 775 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14467 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 905 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48767 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 762 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 49933 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 780 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 26833 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 839 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 14667 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 919 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 8576 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1072 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11633 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1499 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 86733 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 340 |========================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 48367 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 756 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11300 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1493 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 2135 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1069 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 15367 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3835 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 28267 |======================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3533 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 27600 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 862 |========================================================= Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 7548 |======================================================== Flexible IO Tester 3.18 Type: Sequential Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 3776 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1439 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1443 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 11733 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1465 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 52300 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 409 |========================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 23800 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1486 |======================================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 22767 |======================================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 1424 |======================================================== Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 59100 |======================================================= Flexible IO Tester 3.18 Type: Sequential Write - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 462 |========================================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better fio test prox6 . 1525 |======================================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better fio test prox6 . 191 |=========================================================