FIO Corsair Force MP600 1TB AMD Ryzen Threadripper 3970X 32-Core testing with a ASUS ROG ZENITH II EXTREME (0702 BIOS) and AMD Radeon VII 16GB on Ubuntu 19.10 via the Phoronix Test Suite. Corsair Force MP600 1TB: Processor: AMD Ryzen Threadripper 3970X 32-Core @ 3.70GHz (32 Cores / 64 Threads), Motherboard: ASUS ROG ZENITH II EXTREME (0702 BIOS), Chipset: AMD Starship/Matisse, Memory: 64GB, Disk: 1000GB Force MP600, Graphics: AMD Radeon VII 16GB (1802/1001MHz), Audio: AMD Vega 20 HDMI Audio, Monitor: ASUS MG28U, Network: Aquantia AQC107 NBase-T/IEEE + Intel I211 + Intel Device 2723 OS: Ubuntu 19.10, Kernel: 5.3.0-40-generic (x86_64), Desktop: GNOME Shell 3.34.1, Display Server: X Server 1.20.5, Display Driver: amdgpu 19.0.1, OpenGL: 4.5 Mesa 19.2.8 (LLVM 9.0.0), Compiler: GCC 9.2.1 20191008, File-System: ext4, Screen Resolution: 3840x2160 Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4703 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4699 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3635 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1814 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1564 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 400667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4774 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1190 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2163 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 277000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4775 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 593 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3566 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 228333 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3863 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 124000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4040 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64600 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4780 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4777 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3642 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1817 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1560 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 399333 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4774 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1190 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2165 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 277333 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4774 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 593 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3969 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 3965 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3952 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1972 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1230 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 314667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3979 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 991 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1925 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 246333 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4017 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 498 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4775 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4771 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3637 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1815 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1625 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 416000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4773 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1190 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2238 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 286667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4775 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 593 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2782 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2778 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3148 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1570 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 65.5 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 16767 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3774 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 940 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 78.6 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 10100 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4010 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 497 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4082 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4078 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4082 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2037 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1719 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 440000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4077 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1016 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2909 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 372417 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4080 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 506 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3461 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 221667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3956 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 127000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4021 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64300 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2944 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 188667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3319 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 106000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3375 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 53667 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3964 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 3961 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3957 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1975 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1229 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 314667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3992 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 994 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1919 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 245667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4024 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 499 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3545 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 227000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3962 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 127000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4029 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64450 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4779 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4775 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3644 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1818 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1630 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 417333 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4772 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1189 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2218 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 284000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4771 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 593 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1510 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1507 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1440 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 716 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 63.2 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 16167 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1505 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 372 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 75.6 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9679 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1547 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 190 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 148 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9488 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 284 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9073 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 523 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 8361 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2825 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2821 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3165 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1579 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 66.3 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 17000 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3765 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 938 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 78.5 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 10000 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4029 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 500 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1469 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1465 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1461 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 727 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 63.6 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 16267 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1535 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 380 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 76.5 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9790 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1571 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 193 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3882 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 248462 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3966 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 127067 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3958 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 63755 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4081 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4077 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3928 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1960 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1664 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 425933 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4080 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1016 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2901 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 371267 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4066 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 505 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1447 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1444 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1526 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 759 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 747 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 191333 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1886 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 468 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 886 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 113667 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2185 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 270 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3979 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 3975 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4070 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2032 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1900 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 486250 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3936 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 980 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3119 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 399250 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3928 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 487 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3835 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 3831 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3943 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1968 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 368 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 94293 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3975 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 990 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 614 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 78458 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3990 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 495 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3034 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 194000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3245 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 104000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3380 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 54067 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3603 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 230667 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3863 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 124000 |============================================= Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4039 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64600 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 142 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9072 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 198 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 6330 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 357 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 5702 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1454 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1450 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1331 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 662 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 62.2 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 15267 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1353 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 335 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 75.9 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9715 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1408 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 172 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 154 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9872 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 219 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 7010 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 417 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 6659 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 143 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9152 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 200 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 6384 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 358 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 5721 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1463 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1460 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1379 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 686 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 63.8 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 16367 |============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1432 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 354 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 76.5 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9779 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1499 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 184 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3804 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 243267 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3920 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 125533 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4061 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64950 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 990 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 63559 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1114 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 35317 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1166 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 18633 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1431 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1427 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1535 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 764 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 750 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 192000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1957 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 486 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 868 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 111000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2149 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 265 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3857 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 246800 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4056 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 130000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3967 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 63815 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4031 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 4028 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4076 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2034 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1878 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 481000 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3905 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 972 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3110 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 397667 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3974 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 493 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1886 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1883 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1931 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 962 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1182 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 302667 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1830 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 454 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1410 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 180333 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1907 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 235 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 994 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 63682 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1715 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 54867 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2353 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 37633 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3784 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 3780 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4023 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 2008 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 376 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 96217 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 4042 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1007 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 588 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 74913 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3879 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 481 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1735 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 1731 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1819 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 906 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1122 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 287333 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2122 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 527 |================================================ Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1379 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 176333 |============================================= Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 2189 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 270 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 145 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9260 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 238 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 7618 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 410 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 6561 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 145 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 9317 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 237 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 7572 |=============================================== Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 409 |================================================ Flexible IO Tester 3.18 Type: Random Read - Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 6543 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1014 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 64825 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1128 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 36100 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 1188 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: IO_uring - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 19000 |============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 1TB . 3733 |=============================================== Flexible IO Tester 3.18 Type: Random Write - Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 1TB . 238769 |=============================================