raid5-fio-all 2 x AMD EPYC 7351 16-Core testing with a Supermicro H11DSU-iN v2.10 (2.0 BIOS) and ASPEED on CentOS Linux 8 via the Phoronix Test Suite. RAID5_FIO_ALL: Processor: 2 x AMD EPYC 7351 16-Core @ 2.40GHz (32 Cores / 64 Threads), Motherboard: Supermicro H11DSU-iN v2.10 (2.0 BIOS), Chipset: AMD 17h, Memory: 16 x 8192 MB DDR4-2667MT/s, Disk: 6 x 960GB SAMSUNG MZQLB960HAJR-00007 + 256GB SAMSUNG MZVLW256HEHP-000H1, Graphics: ASPEED, Monitor: L1753S, Network: 4 x Intel 10-Gigabit X540-AT2 OS: CentOS Linux 8, Kernel: 4.18.0-80.el8.x86_64 (x86_64), File-System: ext4, Screen Resolution: 1280x1024 Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 16800 |======================================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 807 |========================================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 206333 |======================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1583 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 202333 |======================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2898 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 185667 |======================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 5191 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 166000 |======================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 7748 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 124000 |======================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2054 |========================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 341 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 87400 |======================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 457 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 58600 |======================================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 8609 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 68900 |======================================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 8956 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 35800 |======================================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 9021 |========================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 18000 |======================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 605 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 38733 |======================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 709 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 22520 |======================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 748 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 11967 |======================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 755 |========================================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1113 |========================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1575 |========================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 11400 |======================================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 835 |========================================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 214000 |======================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1606 |========================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 205333 |======================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2945 |========================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 188667 |======================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 5268 |========================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 168667 |======================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 8626 |========================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 138000 |======================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2655 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 404 |========================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 103333 |======================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 620 |========================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 79367 |======================================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 103000 |======================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 51600 |======================================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 25800 |======================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1136 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 72733 |======================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1515 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 48475 |======================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1802 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 28500 |======================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 1889 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: /mnt/data IOPS > Higher Is Better RAID5_FIO_ALL . 15100 |======================================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2035 |========================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: /mnt/data MB/s > Higher Is Better RAID5_FIO_ALL . 2220 |=========================================================