gigabyte60bay-new 2 x Intel Xeon Silver 4208 testing with a GIGABYTE MD61-SC2-00 v01000100 (R07 BIOS) and ASPEED on CentOS Linux 7 via the Phoronix Test Suite. 3 x 238000GB MR9361-8i: Processor: 2 x Intel Xeon Silver 4208 @ 3.20GHz (16 Cores / 32 Threads), Motherboard: GIGABYTE MD61-SC2-00 v01000100 (R07 BIOS), Chipset: Intel Sky Lake-E DMI3 Registers, Memory: 64512MB, Disk: 3 x 238000GB MR9361-8i + 2 x 240GB INTEL SSDSC2BW24, Graphics: ASPEED, Network: 2 x Intel X722 for 1GbE + 2 x QLogic FastLinQ QL41000 10/25/40/50GbE OS: CentOS Linux 7, Kernel: 3.10.0-1062.4.1.el7.x86_64 (x86_64), Desktop: GNOME Shell 3.28.3, Display Server: X Server 1.20.4, Display Driver: modesetting 1.20.4, Compiler: GCC 4.8.5 20150623, File-System: ext4, Screen Resolution: 1024x768 SQLite 3.30.1 Timed SQLite Insertions Seconds < Lower Is Better 3 x 238000GB MR9361-8i . 5.10 |================================================ Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3022 |================================================ Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 37.63 |=============================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1264 |================================================ Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 108.43 |============================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27783 |=============================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4354 |================================================ Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 258 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 66060 |=============================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2925 |================================================ Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 401 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 102680 |============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 530 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3144 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.73 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3626 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.57 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3987 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3.06 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 6.45 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 12.19 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 521 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3259 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.82 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3630 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.48 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4047 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 70.80 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 348 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.85 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 375 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.63 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 348 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 737 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 855 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 63.83 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16333 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 906 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 121 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15527 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1018 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 81.18 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 130 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 171 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.92 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 19.26 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 36.23 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.27 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 17.17 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 35.21 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 297 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 464 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.18 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 482 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.40 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 431 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 250 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15947 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 398 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12600 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 558 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10850 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 703 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 852 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 64.17 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16433 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 923 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 123 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15793 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 982 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 919 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 847 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 710 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 181667 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 904 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 823 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 105500 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 903 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 24.20 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 44.40 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 54.20 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 23.80 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 43.40 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 45.60 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3.21 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 6.48 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 11.67 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 381 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 468 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 567 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 245 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15633 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 408 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13060 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 617 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12171 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 891 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 57007 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 908 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 29073 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 917 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14658 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 947 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 929 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 766 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 196333 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 874 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 849 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 108714 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 903 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 30.67 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 52.33 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 52.41 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 376 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 473 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 542 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 943 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 942 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 964 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 864 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 55253 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 916 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 29260 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 933 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14873 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2436 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3194 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 77.10 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19767 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3335 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 149 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19033 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3474 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2188 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2704 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 30.21 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2848 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 62.43 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2691 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 250 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3281 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.70 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3682 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.38 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4035 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 924 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 969 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 998 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 203 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12892 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 298 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10200 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 385 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1278 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2603 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 77.03 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19733 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3225 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 140 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17600 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3477 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 390 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 375 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 371 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 95100 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 405 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 384 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 48833 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 395 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2468 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2707 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 78.97 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 20233 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2834 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 153 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19633 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2862 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 131 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 260 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 497 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2199 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2728 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 30.18 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2733 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 63.06 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2741 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 50.38 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 308 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.66 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 303 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.20 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 281 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.27 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5.07 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.83 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 282 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3326 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.66 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3719 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.28 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3969 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 49.47 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 308 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.64 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 331 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.30 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 297 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1329 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1327 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 114.86 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 29425 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1283 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 219 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 28027 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1399 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 668 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 814 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 69.76 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17833 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 891 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 135 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17187 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 967 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 761 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1061 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1407 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 246 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15733 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 369 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11500 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 519 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 628 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 40220 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 606 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19333 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 698 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12763 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 662 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 661 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 545 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 139333 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 678 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 563 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 72060 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 670 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 296 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19000 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 516 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16292 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 860 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13767 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2438 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2717 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 77.33 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19833 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2805 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 155 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19900 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2808 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 921 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 950 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 846 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 216600 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 917 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 885 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 113200 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 917 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 934 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1542 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1819 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 130 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 252 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 489 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.19 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.48 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.10 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 52.52 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 323 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.60 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 340 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.33 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 263 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 19.37 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 33.27 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 43.39 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.35 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.71 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.22 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.32 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.63 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.67 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 53.03 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 319 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 0.70 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 319 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1.33 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 315 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 304 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19380 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 378 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12100 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 646 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10590 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1300 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1294 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 102.43 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 26207 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1293 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 228 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 29100 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1354 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 864 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 852 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 675 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 172833 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 873 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 791 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 101133 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 852 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 262 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16747 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 394 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12633 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 668 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12622 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 652 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 794 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 68.63 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17567 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 858 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 132 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16847 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 944 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 866 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 867 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 637 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 163067 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 874 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 714 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 91367 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1002 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 772 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1023 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1347 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 777 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 779 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 779 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 753 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 48142 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 766 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 24393 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 707 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11942 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1264 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10133 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1661 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2027 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 294 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 18800 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 523 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16733 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 850 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13600 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 957 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 61200 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 992 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 31700 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 958 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15333 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 931 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 946 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 886 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 227000 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 916 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 936 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 119667 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 906 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 944 |================================================= Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1558 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1897 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 19.13 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 35.88 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 35.10 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.47 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.90 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9.72 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 20.21 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 34.31 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 47.59 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 20.00 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 34.17 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 34.58 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2.55 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4.62 |================================================ Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 10.39 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 828 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1042 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1215 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 316 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 20253 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 395 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12640 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 618 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10286 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 901 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 57700 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 888 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 28280 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 896 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14307 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 881 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 847 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 666 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 170667 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 859 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 770 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 98487 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 839 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 335 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 509 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 487 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 265 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 16900 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 440 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14080 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 499 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11400 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 748 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 47867 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 853 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27227 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 896 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14300 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 843 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 855 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 629 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 160917 |============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 862 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 734 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 93787 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 985 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 573 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 586 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 586 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1265 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10133 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1660 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2061 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 986 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1045 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1027 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 960 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 61380 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 956 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 30527 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 940 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15050 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 20.70 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 40.91 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 41.50 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 21.19 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 38.91 |=============================================== Flexible IO Tester 3.16 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 41.43 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 776 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1034 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1193 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 903 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 965 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 913 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 833 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 53300 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 858 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27350 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 900 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14340 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 321 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 388 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 453 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 854 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 823 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 872 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 837 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 53200 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 866 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27660 |=============================================== Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 904 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14467 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5705 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5700 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 355 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 90793 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5713 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 751 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 96133 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5726 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3262 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4160 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 84.00 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21500 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4728 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 166 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21267 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5053 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 982 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 980 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1029 |================================================ Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 947 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 946 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 918 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 880 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 865 |================================================= Flexible IO Tester 3.16 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 869 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1428 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 91242 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2563 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 81927 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4326 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 69213 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5701 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5706 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 336 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 86047 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5712 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 749 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 95867 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5725 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1281 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1307 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1567 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 401333 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1234 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1783 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 228083 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1263 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 310 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19800 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 552 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17700 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 871 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13940 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3232 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4140 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 84.77 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21667 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4693 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 167 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21300 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5045 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1617 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1540 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1181 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 302400 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1491 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1598 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 204600 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1577 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2921 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2924 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 383 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 97953 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2904 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 869 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 111667 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2926 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2563 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2833 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 87.70 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 22433 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2895 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 170 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21733 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2832 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4858 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 38720 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5199 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 20787 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5563 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11133 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1305 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 83480 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2467 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 78953 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3999 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 63987 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2032 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 130000 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1989 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 63633 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1726 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27567 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1239 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1308 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1528 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 391333 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1279 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1746 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 223333 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1208 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1206 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10317 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1653 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2213 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 309 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 19767 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 553 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 17700 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 840 |================================================= Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13433 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1787 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 114333 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1825 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 58387 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1777 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 28427 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1578 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1550 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1216 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 311467 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1569 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1606 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 205600 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1634 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1447 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 92507 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2319 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 74087 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2733 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 43733 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2924 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2931 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 399 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 102073 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2933 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 821 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 105040 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2936 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 877 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 863 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 760 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 194667 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 864 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 867 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 111000 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 855 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 321 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 20567 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 569 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 18233 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 877 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14027 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2587 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2862 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 88.93 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 22400 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2878 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 170 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21700 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2858 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 897 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 924 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 708 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 181133 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 994 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 784 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 100480 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1091 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4914 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 39293 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5477 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 21567 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5698 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11400 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1584 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12667 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1455 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1353 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2022 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 129667 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2029 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 64900 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1729 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27620 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1370 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10000 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1801 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2365 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1803 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14413 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1674 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1603 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1787 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 114267 |============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1885 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 60307 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1905 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 30467 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2900 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 23167 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2911 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11667 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2900 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1524 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 97500 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2290 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 73273 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2777 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 44100 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 922 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 58973 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 945 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 30120 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 873 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 13633 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 893 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 875 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 785 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 201000 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 864 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 874 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 111933 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 864 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1332 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 10660 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1759 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2209 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 320 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 20467 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 567 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 18133 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 931 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14900 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 849 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 54350 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 849 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 27167 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 902 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14427 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 1MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 945 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 924 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 667 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 170600 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1002 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 784 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 100325 |============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1117 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1556 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 12467 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1637 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1347 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1785 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14200 |=============================================== Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1668 |================================================ Flexible IO Tester 3.16 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1656 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2919 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 23367 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2929 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 11700 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2928 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 960 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 948 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 945 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 942 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 60120 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 949 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 30340 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 989 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 15693 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1100 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1432 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1881 |================================================ Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 947 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 906 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 921 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 870 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 55573 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 918 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 32KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 29400 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 913 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 64KB - Disk Target: Default Test Directory IOPS > Higher Is Better 3 x 238000GB MR9361-8i . 14593 |=============================================== Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 986 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 970 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 912 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 128KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 958 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 256KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 895 |================================================= Flexible IO Tester 3.16 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 512KB - Disk Target: Default Test Directory MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 890 |================================================= FS-Mark 3.3 Test: 1000 Files, 1MB Size Files/s > Higher Is Better 3 x 238000GB MR9361-8i . 652.84 |============================================== FS-Mark 3.3 Test: 5000 Files, 1MB Size, 4 Threads Files/s > Higher Is Better 3 x 238000GB MR9361-8i . 1140.97 |============================================= FS-Mark 3.3 Test: 4000 Files, 32 Sub Dirs, 1MB Size Files/s > Higher Is Better 3 x 238000GB MR9361-8i . 629.94 |============================================== FS-Mark 3.3 Test: 1000 Files, 1MB Size, No Sync/FSync Files/s > Higher Is Better 3 x 238000GB MR9361-8i . 1356.88 |============================================= Dbench 4.0 12 Clients MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2144.14 |============================================= Dbench 4.0 1 Clients MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 528.17 |============================================== IOzone 3.465 Record Size: 1MB - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4403.77 |============================================= IOzone 3.465 Record Size: 1MB - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5532.47 |============================================= IOzone 3.465 Record Size: 1MB - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5143.68 |============================================= IOzone 3.465 Record Size: 4Kb - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3372.21 |============================================= IOzone 3.465 Record Size: 4Kb - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4753.33 |============================================= IOzone 3.465 Record Size: 4Kb - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4570.05 |============================================= IOzone 3.465 Record Size: 1MB - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 960.81 |============================================== IOzone 3.465 Record Size: 1MB - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 934.18 |============================================== IOzone 3.465 Record Size: 1MB - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 841.71 |============================================== IOzone 3.465 Record Size: 4Kb - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 920.58 |============================================== IOzone 3.465 Record Size: 4Kb - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 885.50 |============================================== IOzone 3.465 Record Size: 4Kb - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 801.21 |============================================== IOzone 3.465 Record Size: 64Kb - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4916.57 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 5184.25 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 6036.51 |============================================= IOzone 3.465 Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3645.61 |============================================= IOzone 3.465 Record Size: 4Kb - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4129.49 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1054.74 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 964.93 |============================================== IOzone 3.465 Record Size: 64Kb - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 861.57 |============================================== IOzone 3.465 Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1065.59 |============================================= IOzone 3.465 Record Size: 4Kb - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1058.04 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4893.50 |============================================= IOzone 3.465 Record Size: 64Kb - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1157.54 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 32MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 7673.42 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 32MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9625.18 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 64MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 8086.37 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 64MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9957.25 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 128MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 8232.01 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 128MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 10400.78 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 256MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 8143.83 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 256MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 10263.65 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 32MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 9904.19 |============================================= Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 32MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 13126.43 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 64MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 10142.60 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 64MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 13374.58 |============================================ Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 32MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 59.07 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 32MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 97.16 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 64MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 57.80 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 64MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 94.18 |=============================================== Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 128MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 10260.40 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 128MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 13800.75 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 256MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 11373.66 |============================================ Threaded I/O Tester 20170503 Test: Read - Size Per Thread: 256MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 14547.86 |============================================ Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 128MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 54.76 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 128MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 92.76 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 256MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 56.49 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 256MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 93.40 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 32MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 112.67 |============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 32MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 136.57 |============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 64MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 101.80 |============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 64MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 119.89 |============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 128MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 96.90 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 128MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 113.62 |============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 256MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 95.00 |=============================================== Threaded I/O Tester 20170503 Test: Write - Size Per Thread: 256MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 110.05 |============================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 32MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 56886.69 |============================================ Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 32MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 66799.73 |============================================ Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 64MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 103349.40 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 64MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 135041.81 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 128MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 218847.71 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 128MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 274260.46 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 256MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 412410.06 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 256MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 545525.87 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 32MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 74099.79 |============================================ Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 32MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 79000.47 |============================================ Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 64MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 148157.47 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 64MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 158666.66 |=========================================== Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 32MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1488.98 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 32MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2247.63 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 64MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2911.43 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 64MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3534.35 |============================================= Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 128MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 325701.94 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 128MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 318364.15 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 256MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 652947.22 |=========================================== Threaded I/O Tester 20170503 Test: Random Read - Size Per Thread: 256MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 616277.68 |=========================================== Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 128MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4665.43 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 128MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 6378.43 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 256MB - Thread Count: 4 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 8203.23 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 256MB - Thread Count: 8 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 13618.78 |============================================ Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 32MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 2208.04 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 32MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1882.37 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 64MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 4235.70 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 64MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 3583.74 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 128MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 7834.26 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 128MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 7799.74 |============================================= Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 256MB - Thread Count: 16 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 15037.85 |============================================ Threaded I/O Tester 20170503 Test: Random Write - Size Per Thread: 256MB - Thread Count: 32 MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 15120.42 |============================================ Compile Bench 0.6 Test: Compile MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1258.99 |============================================= Compile Bench 0.6 Test: Initial Create MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 347.73 |============================================== Compile Bench 0.6 Test: Read Compiled Tree MB/s > Higher Is Better 3 x 238000GB MR9361-8i . 1874.77 |============================================= PostMark 1.51 Disk Transaction Performance TPS > Higher Is Better 3 x 238000GB MR9361-8i . 4122 |================================================