Corsair Force MP600 NVMe SSD Linux AMD Ryzen 9 3900X 12-Core testing with a ASUS ROG CROSSHAIR VIII HERO (WI-FI) (0702 BIOS) and Sapphire AMD Radeon RX 550 640SP / 560/560X 4GB on Ubuntu 18.04 via the Phoronix Test Suite. Corsair Force MP600: Processor: AMD Ryzen 9 3900X 12-Core @ 3.80GHz (12 Cores / 24 Threads), Motherboard: ASUS ROG CROSSHAIR VIII HERO (WI-FI) (0702 BIOS), Chipset: AMD Device 1480, Memory: 16384MB, Disk: 2000GB Force MP600, Graphics: Sapphire AMD Radeon RX 550 640SP / 560/560X 4GB (1300/1750MHz), Audio: AMD Device aae0, Monitor: ASUS VP28U, Network: Realtek Device 8125 + Intel I211 + Intel Device 2723 OS: Ubuntu 18.04, Kernel: 5.2.0-050200rc7-generic (x86_64) 20190630, Desktop: GNOME Shell 3.28.4, Display Server: X Server 1.20.4, Display Driver: modesetting 1.20.4, OpenGL: 4.5 Mesa 19.0.2 (LLVM 8.0.0), Compiler: GCC 7.4.0, File-System: ext4, Screen Resolution: 3840x2160 Compile Bench 0.6 Test: Compile MB/s > Higher Is Better Corsair Force MP600 . 2684.72 |================================================ Compile Bench 0.6 Test: Initial Create MB/s > Higher Is Better Corsair Force MP600 . 736.25 |================================================= Compile Bench 0.6 Test: Read Compiled Tree MB/s > Higher Is Better Corsair Force MP600 . 3988.92 |================================================ Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4227 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1045 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 267467 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4595 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1249 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 159667 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4589 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2260 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 42.40 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 10833 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2908 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 48.17 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3564 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4484 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1050 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 268733 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4569 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1247 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 159667 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4607 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7153 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 41.07 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 10500 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7225 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 588 |==================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 75250 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7207 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2222 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 42.63 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 10900 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2881 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 47.77 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3622 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7196 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 94.94 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 25343 |================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7286 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 828 |==================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 105942 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7332 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4070 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1439 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 368400 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4066 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2748 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 351800 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4071 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4048 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 285 |==================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 72873 |================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4040 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 548 |==================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 70100 |================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3986 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7212 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 974 |==================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 249500 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7165 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1965 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 251667 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7172 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7170 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1083 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 277333 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7188 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2623 |=================================================== Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 335667 |================================================= Flexible IO Tester 3.1 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7267 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4061 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1496 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 383000 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4063 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2922 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 374000 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4079 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5814 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1875 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 480000 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5929 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2805 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 359000 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5862 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4045 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 279 |==================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 71527 |================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4039 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 562 |==================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 71967 |================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3989 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5586 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2443 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 625333 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5486 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3513 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 449667 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5486 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5828 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1888 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 483000 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5955 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2815 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 360333 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5826 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5432 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2459 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 629667 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5453 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3496 |=================================================== Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 447667 |================================================= Flexible IO Tester 3.1 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5462 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3315 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1580 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 404467 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4781 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1944 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 249000 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4790 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2415 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 357 |==================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 91400 |================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3763 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 651 |==================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 83233 |================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4043 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4780 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1665 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 426333 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4758 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1956 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 250333 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4789 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7199 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2826 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 723333 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7280 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4454 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 570333 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7315 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2350 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 351 |==================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 89973 |================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3436 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 627 |==================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 80247 |================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3822 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7296 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2703 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 692000 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7321 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 6656 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 852000 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7330 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4065 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1453 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 372000 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4064 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2741 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 350917 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4075 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4042 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 286 |==================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 73193 |================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4037 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 558 |==================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 71367 |================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3987 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7272 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2840 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 727000 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7224 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4317 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 552667 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7190 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7225 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2629 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 673333 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7205 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 6446 |=================================================== Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 825000 |================================================= Flexible IO Tester 3.1 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 7246 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4064 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 1407 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 360267 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4065 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2686 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 343933 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4076 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5858 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2191 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 561000 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5991 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3221 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 412000 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5915 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4023 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 294 |==================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 74900 |================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 4031 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 543 |==================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 69357 |================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3989 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5486 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3057 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 782667 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5581 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3822 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 489333 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5601 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5914 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 2175 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 556667 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5826 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3228 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 413333 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: Linux AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5870 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 2MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5553 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3101 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 793667 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5612 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 3776 |=================================================== Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8KB - Disk Target: Default Test Directory IOPS > Higher Is Better Corsair Force MP600 . 483333 |================================================= Flexible IO Tester 3.1 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 8MB - Disk Target: Default Test Directory MB/s > Higher Is Better Corsair Force MP600 . 5581 |=================================================== FS-Mark 3.3 Test: 1000 Files, 1MB Size Files/s > Higher Is Better Corsair Force MP600 . 576.24 |================================================= FS-Mark 3.3 Test: 5000 Files, 1MB Size, 4 Threads Files/s > Higher Is Better Corsair Force MP600 . 1380.17 |================================================ FS-Mark 3.3 Test: 4000 Files, 32 Sub Dirs, 1MB Size Files/s > Higher Is Better Corsair Force MP600 . 604.90 |================================================= FS-Mark 3.3 Test: 1000 Files, 1MB Size, No Sync/FSync Files/s > Higher Is Better Corsair Force MP600 . 3069.17 |================================================ PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Normal Load - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 102311.45 |============================================== PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Normal Load - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 6108.52 |================================================ PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Single Thread - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 2806.07 |================================================ PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Normal Load - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 161392.44 |============================================== PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Single Thread - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 287.31 |================================================= PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Normal Load - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 292317.56 |============================================== PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Normal Load - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 7008.73 |================================================ PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Normal Load - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 8732.25 |================================================ PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Single Thread - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 4384.18 |================================================ PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Heavy Contention - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 99945.41 |=============================================== PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Single Thread - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 28230.44 |=============================================== PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Single Thread - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 303.20 |================================================= PostgreSQL pgbench 10.3 Scaling: On-Disk - Test: Heavy Contention - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 5776.57 |================================================ PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Single Thread - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 1066.52 |================================================ PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Heavy Contention - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 161439.42 |============================================== PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Heavy Contention - Mode: Read Only TPS > Higher Is Better Corsair Force MP600 . 298042.46 |============================================== PostgreSQL pgbench 10.3 Scaling: Mostly RAM - Test: Heavy Contention - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 6982.34 |================================================ PostgreSQL pgbench 10.3 Scaling: Buffer Test - Test: Heavy Contention - Mode: Read Write TPS > Higher Is Better Corsair Force MP600 . 8829.62 |================================================ MariaDB 10.3.8 Clients: 1 Queries Per Second > Higher Is Better Corsair Force MP600 . 2684 |=================================================== MariaDB 10.3.8 Clients: 4 Queries Per Second > Higher Is Better Corsair Force MP600 . 1679 |=================================================== MariaDB 10.3.8 Clients: 8 Queries Per Second > Higher Is Better Corsair Force MP600 . 1678 |=================================================== MariaDB 10.3.8 Clients: 16 Queries Per Second > Higher Is Better Corsair Force MP600 . 1662 |=================================================== MariaDB 10.3.8 Clients: 32 Queries Per Second > Higher Is Better Corsair Force MP600 . 1567 |=================================================== MariaDB 10.3.8 Clients: 64 Queries Per Second > Higher Is Better Corsair Force MP600 . 1046 |=================================================== MariaDB 10.3.8 Clients: 128 Queries Per Second > Higher Is Better Corsair Force MP600 . 517 |==================================================== MariaDB 10.3.8 Clients: 256 Queries Per Second > Higher Is Better Corsair Force MP600 . 418 |====================================================