Running pts/t-test1-1.0.0 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 1803270-KH-N2920201849
N2920_20180328-3
Running pts/t-test1-1.0.0 via the Phoronix Test Suite.
SanDisk SSD i110:
Processor: Intel Celeron N2920 @ 2.00GHz (4 Cores), Motherboard: AMI Aptio CRB, Chipset: Intel Atom Z36xxx/Z37xxx, Memory: 1 x 2048 MB DDR3-1333MHz Kingston, Disk: 32GB SanDisk SSD i110, Graphics: Intel Atom Z36xxx/Z37xxx & Display, Audio: Realtek ALC662 rev3, Monitor: Acer S220HQL, Network: Realtek RTL8111/8168/8411
OS: Ubuntu 16.04, Kernel: 4.13.0-37-generic (x86_64), Desktop: Unity 7.4.0, Display Server: X Server 1.18.4, Display Driver: modesetting 1.18.4, OpenGL: 3.3 Mesa 12.0.6, Compiler: GCC 5.4.0 20160609, File-System: ext4, Screen Resolution: 1920x1080
2048 MB DDR3-1333MHz Kingston:
Processor: Intel Celeron N2920 @ 2.00GHz (4 Cores), Motherboard: AMI Aptio CRB, Chipset: Intel Atom Z36xxx/Z37xxx, Memory: 1 x 2048 MB DDR3-1333MHz Kingston, Disk: 32GB SanDisk SSD i110, Graphics: Intel Atom Z36xxx/Z37xxx & Display, Audio: Realtek ALC662 rev3, Monitor: Acer S220HQL, Network: Realtek RTL8111/8168/8411
OS: Ubuntu 16.04, Kernel: 4.13.0-37-generic (x86_64), Desktop: Unity 7.4.0, Display Server: X Server 1.18.4, Display Driver: modesetting 1.18.4, OpenGL: 3.3 Mesa 12.0.6, Compiler: GCC 5.4.0 20160609, File-System: ext4, Screen Resolution: 1920x1080
IOzone 3.465
Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance
MB/s > Higher Is Better
SanDisk SSD i110 . 1537.52 |===================================================
IOzone 3.465
Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance
MB/s > Higher Is Better
SanDisk SSD i110 . 56.75 |=====================================================
Threaded I/O Tester 20170503
Test: Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
SanDisk SSD i110 . 2481.70 |===================================================
Threaded I/O Tester 20170503
Test: Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
SanDisk SSD i110 . 1.72 |======================================================
Threaded I/O Tester 20170503
Test: Random Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
SanDisk SSD i110 . 6456.88 |===================================================
Threaded I/O Tester 20170503
Test: Random Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
SanDisk SSD i110 . 13.66 |=====================================================
t-test1 2017-01-13
Threads: 1
Seconds < Lower Is Better
2048 MB DDR3-1333MHz Kingston . 115.76 |=======================================
t-test1 2017-01-13
Threads: 2
Seconds < Lower Is Better
2048 MB DDR3-1333MHz Kingston . 37.44 |========================================