sata-port-multiplier AMD Ryzen 7 1700 Eight-Core testing with a ASUS PRIME X370-PRO and AMD Radeon R9 380 (AMD TONGA / DRM 3.10.0 / 4.11.4-041104-generic LLVM 5.0.0) 4096MB on neon 16.04 via the Phoronix Test Suite. mdadm raid10: Processor: AMD Ryzen 7 1700 Eight-Core @ 3.00GHz (16 Cores), Motherboard: ASUS PRIME X370-PRO, Chipset: AMD Device 1450, Memory: 2 x 16384 MB DDR4-1333MHz CMK32GX4M2A2666C16, Disk: 256GB Samsung SSD 840 + 1000GB Western Digital WD10EACS-00Z + 500GB SAMSUNG HD501LJ + 5 x 500GB Seagate ST500LM021-1KJ15 + Samsung SSD 960 EVO 500GB, Graphics: AMD Radeon R9 380 (AMD TONGA / DRM 3.10.0 / 4.11.4-041104-generic LLVM 5.0.0) 4096MB, Audio: AMD Tonga HDMI Audio, Monitor: PHL BDM3270, Network: Intel I211 Gigabit Connection OS: neon 16.04, Kernel: 4.11.4-041104-generic (x86_64), Desktop: KDE Frameworks 5, Display Server: X Server 1.18.4, Display Driver: modesetting 1.18.4, OpenGL: 4.5 Mesa 17.2.0-devel- padoka PPA (LLVM 5.0.0), OpenCL: OpenCL 1.1 Mesa 17.2.0-devel- padoka PPA, Vulkan: 1.0.3, Compiler: GCC 5.4.0 20160609 + Clang 3.8.0-2ubuntu4 + LLVM 5.0.0, File-System: ext4, Screen Resolution: 2560x1440 mdadm raid10 2: Processor: AMD Ryzen 7 1700 Eight-Core @ 3.00GHz (16 Cores), Motherboard: ASUS PRIME X370-PRO, Chipset: AMD Device 1450, Memory: 2 x 16384 MB DDR4-1333MHz CMK32GX4M2A2666C16, Disk: 256GB Samsung SSD 840 + 1000GB Western Digital WD10EACS-00Z + 500GB SAMSUNG HD501LJ + 5 x 500GB Seagate ST500LM021-1KJ15 + Samsung SSD 960 EVO 500GB, Graphics: AMD Radeon R9 380 (AMD TONGA / DRM 3.10.0 / 4.11.4-041104-generic LLVM 5.0.0) 4096MB, Audio: AMD Tonga HDMI Audio, Monitor: PHL BDM3270, Network: Intel I211 Gigabit Connection OS: neon 16.04, Kernel: 4.11.4-041104-generic (x86_64), Desktop: KDE Frameworks 5, Display Server: X Server 1.18.4, Display Driver: modesetting 1.18.4, OpenGL: 4.5 Mesa 17.2.0-devel- padoka PPA (LLVM 5.0.0), OpenCL: OpenCL 1.1 Mesa 17.2.0-devel- padoka PPA, Vulkan: 1.0.3, Compiler: GCC 5.4.0 20160609 + Clang 3.8.0-2ubuntu4 + LLVM 5.0.0, File-System: ext4, Screen Resolution: 2560x1440 btrfs raid10 - raid1 metadata: Processor: AMD Ryzen 7 1700 Eight-Core @ 3.00GHz (16 Cores), Motherboard: ASUS PRIME X370-PRO, Chipset: AMD Device 1450, Memory: 2 x 16384 MB DDR4-1333MHz CMK32GX4M2A2666C16, Disk: 256GB Samsung SSD 840 + 1000GB Western Digital WD10EACS-00Z + 500GB SAMSUNG HD501LJ + 5 x 500GB Seagate ST500LM021-1KJ15 + Samsung SSD 960 EVO 500GB, Graphics: AMD Radeon R9 380 (AMD TONGA / DRM 3.10.0 / 4.11.4-041104-generic LLVM 5.0.0) 4096MB, Audio: AMD Tonga HDMI Audio, Monitor: PHL BDM3270, Network: Intel I211 Gigabit Connection OS: neon 16.04, Kernel: 4.11.4-041104-generic (x86_64), Desktop: KDE Frameworks 5, Display Server: X Server 1.18.4, Display Driver: modesetting 1.18.4, OpenGL: 4.5 Mesa 17.2.0-devel- padoka PPA (LLVM 5.0.0), OpenCL: OpenCL 1.1 Mesa 17.2.0-devel- padoka PPA, Vulkan: 1.0.3, Compiler: GCC 5.4.0 20160609 + Clang 3.8.0-2ubuntu4 + LLVM 5.0.0, File-System: ext4, Screen Resolution: 2560x1440 Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 55.21 |========================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 50 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 54.29 |========================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 23 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 154 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 .................. 78.63 |============================= mdadm raid10 2 ................ 80.78 |============================= btrfs raid10 - raid1 metadata . 106.98 |======================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 .................. 16 |============================== mdadm raid10 2 ................ 16 |============================== btrfs raid10 - raid1 metadata . 23 |=========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 1.23 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 150 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 114.58 |======================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 11 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 2.46 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 150 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 164.19 |======================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 7 |============================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 4.74 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 145 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 188.93 |======================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 4 |============================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 9.34 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 142 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 202.19 |======================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 2 |============================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 88.85 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 84 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 90.87 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 41 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 80.01 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 19999 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 .................. 93.18 |======================================== mdadm raid10 2 ................ 88.25 |====================================== btrfs raid10 - raid1 metadata . 58.21 |========================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 .................. 20 |=========================================== mdadm raid10 2 ................ 18 |======================================= btrfs raid10 - raid1 metadata . 11 |======================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 72.77 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 9093 |========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 86.97 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 8 |============================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 17.40 |========================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 133 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 202.76 |======================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1 |============================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 30.75 |========================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 116 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 51.94 |========================================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 98 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 85.88 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 5364 |========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 92.19 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 2 |============================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 134.56 |======================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 4202 |========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 294.40 |======================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 7 |============================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 87.81 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1369 |========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 208.30 |======================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 11 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 94.65 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 736 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 88.62 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 88.79 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 344 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 90.10 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 173 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 104.57 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 98 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 112.17 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 51 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 107.75 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 26935 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 .................. 107.92 |=============================== mdadm raid10 2 ................ 108.97 |================================ btrfs raid10 - raid1 metadata . 134.02 |======================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 .................. 23 |================================== mdadm raid10 2 ................ 23 |================================== btrfs raid10 - raid1 metadata . 29 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 103.77 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 12967 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 126.70 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 12 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 109.20 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 6822 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 143.86 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 5 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 105.62 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 3297 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 144.46 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 3 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 109.57 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1708 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 144.87 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 89.28 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 1MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 84 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 92.10 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 2MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 42 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 88.30 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 22071 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 .................. 92.30 |===================================== mdadm raid10 2 ................ 98.50 |======================================== btrfs raid10 - raid1 metadata . 86.13 |=================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 .................. 19 |======================================= mdadm raid10 2 ................ 21 |=========================================== btrfs raid10 - raid1 metadata . 18 |===================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 87.52 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 10937 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 87.38 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 8MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 8 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 107.56 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 837 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 140.55 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 110.45 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 428 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 105.60 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 203 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 91.89 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 5740 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 92.54 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 16MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 2 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 93.96 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 2933 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 91.29 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 32MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 90.42 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 1409 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 64MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 89.98 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 91.35 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 711 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 164.01 |======================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 128MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 3 |============================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 91.52 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 256KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 354 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 . 99.35 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: No - Block Size: 512KB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 . 190 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 76.02 |========================== btrfs raid10 - raid1 metadata . 112.33 |======================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 15 |=========================== btrfs raid10 - raid1 metadata . 24 |=========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 77.55 |============================= btrfs raid10 - raid1 metadata . 104.92 |======================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 16 |=============================== btrfs raid10 - raid1 metadata . 22 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 94.45 |======================================== btrfs raid10 - raid1 metadata . 73.19 |=============================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 20 |=========================================== btrfs raid10 - raid1 metadata . 15 |================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 79.28 |================= btrfs raid10 - raid1 metadata . 181.80 |======================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 16 |================= btrfs raid10 - raid1 metadata . 41 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 96.90 |======================================== btrfs raid10 - raid1 metadata . 74.29 |=============================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 20 |=========================================== btrfs raid10 - raid1 metadata . 15 |================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 269.21 |======================================= btrfs raid10 - raid1 metadata . 56.99 |======== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 64 |=========================================== btrfs raid10 - raid1 metadata . 12 |======== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 93.30 |========================= btrfs raid10 - raid1 metadata . 144.39 |======================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 19 |========================== btrfs raid10 - raid1 metadata . 31 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 96.09 |========================== btrfs raid10 - raid1 metadata . 146.39 |======================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 20 |========================== btrfs raid10 - raid1 metadata . 33 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 89.62 |======================================== btrfs raid10 - raid1 metadata . 72.39 |================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 18 |=========================================== btrfs raid10 - raid1 metadata . 14 |================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 106.67 |=========================== btrfs raid10 - raid1 metadata . 152.26 |======================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 23 |============================= btrfs raid10 - raid1 metadata . 34 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 89.88 |======================================== btrfs raid10 - raid1 metadata . 74.99 |================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 18 |=========================================== btrfs raid10 - raid1 metadata . 15 |==================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk MB/s > Higher Is Better mdadm raid10 2 ................ 90.21 |======================================== btrfs raid10 - raid1 metadata . 78.72 |=================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Direct: Yes - Block Size: 4MB - Disk Target: /mnt/5disk IOPS > Higher Is Better mdadm raid10 2 ................ 19 |=========================================== btrfs raid10 - raid1 metadata . 16 |====================================