VMware testing on CentOS Linux 7 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 1607108-HA-1607106HA88
fio-9k
VMware testing on CentOS Linux 7 via the Phoronix Test Suite.
Virtual disk:
Processor: 16 x Intel Xeon E5-2680 v3 @ 2.50GHz (16 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 12 x 16384 MB DRAM, Disk: 64GB Virtual disk + 8 x 1049GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS Linux 7, Kernel: 4.7.0-0.rc4.git0.1.el7.centos.x86_64 (x86_64) 20160621, Desktop: GNOME Shell 3.14.4, Display Driver: vmware 13.0.2, Compiler: GCC 4.8.5 20150623, File-System: ext4, Screen Resolution: 1672x1254, System Layer: VMware
fio-1500mtu:
Processor: 16 x Intel Xeon E5-2680 v3 @ 2.50GHz (16 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 12 x 16384 MB DRAM, Disk: 64GB Virtual disk + 8 x 1049GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS Linux 7, Kernel: 4.7.0-0.rc4.git0.1.el7.centos.x86_64 (x86_64) 20160621, Desktop: GNOME Shell 3.14.4, Display Driver: vmware 13.0.2, Compiler: GCC 4.8.5 20150623, File-System: ext4, Screen Resolution: 1672x1254, System Layer: VMware
Flexible IO Tester 2.1.13
Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: MB/s
MB/s > Higher Is Better
Virtual disk . 171.03 |========================================================
fio-1500mtu .. 168.41 |=======================================================
Flexible IO Tester 2.1.13
Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: IOPS
IOPS > Higher Is Better
Virtual disk . 18 |============================================================
fio-1500mtu .. 17 |=========================================================
Flexible IO Tester 2.1.13
Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: MB/s
MB/s > Higher Is Better
Virtual disk . 239.08 |========================================================
fio-1500mtu .. 212.42 |==================================================
Flexible IO Tester 2.1.13
Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: IOPS
IOPS > Higher Is Better
Virtual disk . 26 |============================================================
fio-1500mtu .. 26 |============================================================
Flexible IO Tester 2.1.13
Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: MB/s
MB/s > Higher Is Better
Virtual disk . 180.36 |========================================================
fio-1500mtu .. 175.16 |======================================================
Flexible IO Tester 2.1.13
Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: IOPS
IOPS > Higher Is Better
Virtual disk . 20 |==============================================
fio-1500mtu .. 26 |============================================================
Flexible IO Tester 2.1.13
Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: MB/s
MB/s > Higher Is Better
Virtual disk . 239.48 |================================================
fio-1500mtu .. 279.95 |========================================================
Flexible IO Tester 2.1.13
Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: Yes - Block Size: 8MB - Disk Target: /btrfs - Result: IOPS
IOPS > Higher Is Better
Virtual disk . 17 |====================================
fio-1500mtu .. 28 |============================================================