Running pts/tiobench-1.2.0 via the Phoronix Test Suite.
Compare your own system(s) to this result file with the
Phoronix Test Suite by running the command:
phoronix-test-suite benchmark 1507084-DE-R6D12C25675
r6d12c256drbd2mpio
Running pts/tiobench-1.2.0 via the Phoronix Test Suite.
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware:
Processor: Intel Xeon E5430 @ 2.66GHz (1 Core), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 2048MB, Disk: 34GB Virtual disk + 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS Linux 7, Kernel: 3.10.0-229.1.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.3 20140911, File-System: ext2, Screen Resolution: 1672x1254, System Layer: VMware
Virtual disk:
Processor: Intel Xeon E5430 @ 2.66GHz (1 Core), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 2048MB, Disk: 34GB Virtual disk + 215GB Virtual disk, Graphics: VMware SVGA II, Network: VMware VMXNET3
OS: CentOS Linux 7, Kernel: 3.10.0-229.1.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.3 20140911, File-System: ext2, Screen Resolution: 1672x1254, System Layer: VMware
Dbench 4.0
Client Count: 1
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 206.13 |====================
Dbench 4.0
Client Count: 6
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 338.28 |====================
Dbench 4.0
Client Count: 12
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 359.84 |====================
Dbench 4.0
Client Count: 48
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 400.15 |====================
Dbench 4.0
Client Count: 128
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 409.86 |====================
Dbench 4.0
Client Count: 256
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 345.58 |====================
IOzone 3.405
Record Size: 1MB - File Size: 2GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 111.85 |====================
IOzone 3.405
Record Size: 1MB - File Size: 4GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 105.47 |====================
IOzone 3.405
Record Size: 1MB - File Size: 8GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 107.43 |====================
IOzone 3.405
Record Size: 4Kb - File Size: 2GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 111.48 |====================
IOzone 3.405
Record Size: 4Kb - File Size: 4GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 105.30 |====================
IOzone 3.405
Record Size: 4Kb - File Size: 8GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 107.40 |====================
IOzone 3.405
Record Size: 1MB - File Size: 2GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 90.88 |=====================
IOzone 3.405
Record Size: 1MB - File Size: 4GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 93.69 |=====================
IOzone 3.405
Record Size: 1MB - File Size: 8GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 92.67 |=====================
IOzone 3.405
Record Size: 4Kb - File Size: 2GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 90.48 |=====================
IOzone 3.405
Record Size: 4Kb - File Size: 4GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 92.66 |=====================
IOzone 3.405
Record Size: 4Kb - File Size: 8GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 92.85 |=====================
IOzone 3.405
Record Size: 64Kb - File Size: 2GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 111.97 |====================
IOzone 3.405
Record Size: 64Kb - File Size: 4GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 110.99 |====================
IOzone 3.405
Record Size: 64Kb - File Size: 8GB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 107.71 |====================
IOzone 3.405
Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 2618.45 |===================
IOzone 3.405
Record Size: 4Kb - File Size: 512MB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 2364.67 |===================
IOzone 3.405
Record Size: 64Kb - File Size: 2GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 115.01 |====================
IOzone 3.405
Record Size: 64Kb - File Size: 4GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 97.34 |=====================
IOzone 3.405
Record Size: 64Kb - File Size: 8GB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 96.01 |=====================
IOzone 3.405
Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 173.26 |====================
IOzone 3.405
Record Size: 4Kb - File Size: 512MB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 165.98 |====================
IOzone 3.405
Record Size: 64Kb - File Size: 512MB - Disk Test: Read Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 2642.16 |===================
IOzone 3.405
Record Size: 64Kb - File Size: 512MB - Disk Test: Write Performance
MB/s > Higher Is Better
RAID 6 12 HDD chunk 256k DRBD 2MPIO 1Gbps VMware . 178.19 |====================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1793.02 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1762.19 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1820.00 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1697.17 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1786.58 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1771.76 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1867.88 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 111.77 |========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 1650.28 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 1679.03 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 1686.06 |=======================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 112.06 |========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 10.48 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 15.37 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 10.36 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 11.64 |=========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 112.10 |========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 110.81 |========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 112.01 |========================================================
Threaded I/O Tester 0.3.3
Test: Read - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 112.01 |========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 10.57 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 13.58 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 10.42 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 12.31 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 14.75 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 21.17 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 12.47 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 21.11 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 12.40 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 21.11 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 12.39 |=========================================================
Threaded I/O Tester 0.3.3
Test: Write - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 21.16 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1576.96 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1546.37 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1510.17 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1413.92 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1371.62 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 1370.46 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 1265.91 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 128.94 |========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 1529.62 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 1481.63 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 1327.04 |=======================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 136.65 |========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 15.19 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 15.72 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 14.37 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 14.03 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 154.10 |========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 11.02 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 11.57 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Read - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 5.95 |==========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 16.25 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 13.04 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 4
MB/s > Higher Is Better
Virtual disk . 16.53 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 8
MB/s > Higher Is Better
Virtual disk . 13.90 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 18.15 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 32MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 23.43 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 14.08 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 64MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 24.12 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 16.54 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 128MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 26.24 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 16
MB/s > Higher Is Better
Virtual disk . 16.10 |=========================================================
Threaded I/O Tester 0.3.3
Test: Random Write - Size Per Thread: 256MB - Thread Count: 32
MB/s > Higher Is Better
Virtual disk . 24.97 |=========================================================