storages VMware testing on Debian 7.8 via the Phoronix Test Suite. R10 disk:8 512k noSSDcache: Processor: 2 x Intel @ 2.89GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 8192 MB DRAM, Disk: 34GB Virtual disk, Graphics: VMware SVGA II, Network: Intel 82545EM Gigabit OS: Debian 7.8, Kernel: 3.2.0-4-amd64 (x86_64), Compiler: GCC 4.7.2, File-System: ext4, System Layer: VMware Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 155 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 162.17 |========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 263 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 1.07 |============================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 263 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 2.13 |============================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 257 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 4.18 |============================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 247 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 8.05 |============================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 242 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 15.62 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 435 |============================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 449.38 |========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1910 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 7.54 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1954 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 15.35 |=========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 254 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 37.14 |=========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 231 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 61.09 |=========================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 189 |============================================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 97.65 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1908 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 30.39 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 2104 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 68.12 |=========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 2243 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 146.91 |========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 2021 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 257.28 |========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1413 |============================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 362.00 |========================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 863 |============================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 446.52 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 456 |============================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 479.77 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8980 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 37.26 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8883 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 74.26 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8435 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 133.71 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 7446 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 237.91 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 5541 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 353.41 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 684 |============================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 1MB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 707.73 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 9043 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 4KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 36.62 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8713 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 8KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 72.49 |=========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 4480 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 572.46 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 2355 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 600.91 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1261 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 643.52 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8371 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 137.55 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 8268 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 32KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 257.12 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 6944 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 460.19 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 5384 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 128KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 700.20 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 2736 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 256KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 703.75 |========================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: IOPS IOPS > Higher Is Better R10 disk:8 512k noSSDcache . 1369 |============================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Direct: No - Block Size: 512KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 709.52 |========================================== FS-Mark 3.3 Test: 1000 Files, 1MB Size Files/s > Higher Is Better R10 disk:8 512k noSSDcache . 577.75 |========================================== FS-Mark 3.3 Test: 5000 Files, 1MB Size, 4 Threads Files/s > Higher Is Better R10 disk:8 512k noSSDcache . 680.80 |========================================== FS-Mark 3.3 Test: 4000 Files, 32 Sub Dirs, 1MB Size Files/s > Higher Is Better R10 disk:8 512k noSSDcache . 655.60 |========================================== FS-Mark 3.3 Test: 1000 Files, 1MB Size, No Sync/FSync Files/s > Higher Is Better R10 disk:8 512k noSSDcache . 1969.93 |========================================= IOzone 3.405 Record Size: 1MB - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 6968.26 |========================================= IOzone 3.405 Record Size: 1MB - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 7197.74 |========================================= IOzone 3.405 Record Size: 1MB - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 1009.43 |========================================= IOzone 3.405 Record Size: 4Kb - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 6790.57 |========================================= IOzone 3.405 Record Size: 4Kb - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 6949.88 |========================================= IOzone 3.405 Record Size: 4Kb - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 1207.24 |========================================= IOzone 3.405 Record Size: 1MB - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 654.30 |========================================== IOzone 3.405 Record Size: 1MB - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 665.26 |========================================== IOzone 3.405 Record Size: 1MB - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 681.01 |========================================== IOzone 3.405 Record Size: 4Kb - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 629.14 |========================================== IOzone 3.405 Record Size: 4Kb - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 662.89 |========================================== IOzone 3.405 Record Size: 4Kb - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 663.15 |========================================== IOzone 3.405 Record Size: 64Kb - File Size: 2GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 7799.84 |========================================= IOzone 3.405 Record Size: 64Kb - File Size: 4GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 7983.45 |========================================= IOzone 3.405 Record Size: 64Kb - File Size: 8GB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 1157.66 |========================================= IOzone 3.405 Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 4905.25 |========================================= IOzone 3.405 Record Size: 4Kb - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 5410.91 |========================================= IOzone 3.405 Record Size: 64Kb - File Size: 2GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 656.72 |========================================== IOzone 3.405 Record Size: 64Kb - File Size: 4GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 673.85 |========================================== IOzone 3.405 Record Size: 64Kb - File Size: 8GB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 668.45 |========================================== IOzone 3.405 Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 678.17 |========================================== IOzone 3.405 Record Size: 4Kb - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 624.19 |========================================== IOzone 3.405 Record Size: 64Kb - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 6342.46 |========================================= IOzone 3.405 Record Size: 64Kb - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better R10 disk:8 512k noSSDcache . 717.74 |==========================================