odroid-disk Running pts/aio-stress-1.1.1, pts/sqlite-1.8.0, pts/fio-1.7.1, pts/iozone-1.8.0 via the Phoronix Test Suite. ODROID-U3: Processor: Exynos ARMv7 rev 0 @ 1.70GHz (4 Cores), Motherboard: ODROID-U2/U3, Memory: 2048MB, Disk: 32GB NCard + 16GB SDW16G, Monitor: EP-HDMI-RX OS: Ubuntu 14.04, Kernel: 3.8.13.30 (armv7l), Compiler: GCC 4.8.2, File-System: ext4, Screen Resolution: 1280x720 ODROID-C1: Processor: ARMv7 rev 1 @ 1.54GHz (4 Cores), Motherboard: ODROIDC, Memory: 847MB, Disk: 16GB SDW16G OS: Ubuntu 14.04, Kernel: 3.10.70-74 (armv7l), Compiler: GCC 4.9.2, File-System: ext4, Screen Resolution: 1920x2160 AIO-Stress 0.21 Test: Random Write MB/s > Higher Is Better ODROID-U3 . 10.46 |============================== ODROID-C1 . 21.23 |============================================================ SQLite 3.7.3 Test Target: Default Test Directory Seconds < Lower Is Better ODROID-U3 . 168.02 |================================================ ODROID-C1 . 205.20 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 24.18 |==================================== ODROID-C1 . 40.81 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 27.10 |========================================= ODROID-C1 . 39.52 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 10.70 |=========================== ODROID-C1 . 23.50 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Libaio - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 45.31 |========================================================= ODROID-C1 . 47.98 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 10.62 |======================== ODROID-C1 . 27.07 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Libaio - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 26.85 |========================================= ODROID-C1 . 39.22 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Libaio - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 9.31 |===================== ODROID-C1 . 26.12 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Libaio - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 8.56 |=================== ODROID-C1 . 27.25 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 29.41 |=================================== ODROID-C1 . 49.95 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 24.44 |=================================== ODROID-C1 . 41.48 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 52.13 |================================================== ODROID-C1 . 62.54 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 13.00 |================================= ODROID-C1 . 23.77 |============================================================ Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: POSIX AIO - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 27.06 |========================================= ODROID-C1 . 40.07 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 10.30 |========================== ODROID-C1 . 23.74 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Libaio - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 71.55 |============================================================ ODROID-C1 . 63.20 |===================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 15.99 |============================== ODROID-C1 . 32.41 |============================================================ Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: POSIX AIO - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 10.98 |======================== ODROID-C1 . 27.07 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Libaio - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 51.53 |================================================= ODROID-C1 . 62.78 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Libaio - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 24.41 |============================================ ODROID-C1 . 33.57 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Libaio - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 24.60 |============================================= ODROID-C1 . 33.08 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 29.34 |=================================== ODROID-C1 . 50.76 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: POSIX AIO - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 51.67 |================================================= ODROID-C1 . 62.72 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: No - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 14.98 |====================================== ODROID-C1 . 23.94 |============================================================ Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: POSIX AIO - Buffered: Yes - Block Size: 64KB - Disk Target: Default Test Directory - Result: MB/s MB/s > Higher Is Better ODROID-U3 . 23.77 |============================================ ODROID-C1 . 32.46 |============================================================ IOzone 3.405 Record Size: 1MB - File Size: 512MB - Disk Test: Read Performance MB/s > Higher Is Better ODROID-U3 . 781.23 |=========================================================== ODROID-C1 . 738.03 |======================================================== IOzone 3.405 Record Size: 1MB - File Size: 512MB - Disk Test: Write Performance MB/s > Higher Is Better ODROID-U3 . 10.89 |===================== ODROID-C1 . 31.43 |============================================================