痢n0129 2 x Intel Xeon Silver 4114 testing with a Dell 0N6JWX and mgadrmfb on CentOS Linux 7 via the Phoronix Test Suite. DELLBOSS VD: Processor: 2 x Intel Xeon Silver 4114 @ 2.20GHz (20 Cores / 40 Threads), Motherboard: Dell 0N6JWX, Chipset: Intel Device 2020, Memory: 4 x 16384 MB DDR4-2400MHz M393A2K43BB1-CTD, Disk: 120GB DELLBOSS VD + 2 x 480GB PERC H740P Adp, Graphics: mgadrmfb, Monitor: DELL P2417H, Network: Broadcom Limited BCM57416 NetXtreme-E 10GBase-T RDMA OS: CentOS Linux 7, Kernel: 3.10.0-693.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623 + CUDA 8.0, File-System: xfs, Screen Resolution: 1600x900 Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 56.13 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 3507 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 53.90 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 3368 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 107.47 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 6717 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 45.55 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 2847 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 108.58 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 6786 |=========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 183.69 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 11480 |========================================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 359.07 |========================================================= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 22442 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 56.43 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 3526 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 56.41 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 3525 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 243.45 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 15215 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 111.34 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 6958 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 226.32 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 14144 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 108.60 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 6787 |=========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 240.07 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 15004 |========================================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 204.14 |========================================================= Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: Yes - Direct: Yes - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 12759 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / MB/s > Higher Is Better DELLBOSS VD . 56.48 |========================================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: No - Block Size: 16KB - Disk Target: / IOPS > Higher Is Better DELLBOSS VD . 3530 |===========================================================