Тест загальної швидкодії системи MDADM VMware testing on CentOS Linux 7 via the Phoronix Test Suite. VMWare MDADM RAID10 HDD: Processor: 4 x Intel Xeon L5640 @ 2.27GHz (8 Cores), Motherboard: Intel 440BX, Chipset: Intel 440BX/ZX/DX, Memory: 1 x 4096 MB DRAM, Disk: 3GB VMware Virtual S + 4 x 1999GB MR9266-8i, Graphics: VMware SVGA II, Network: VMware VMXNET3 OS: CentOS Linux 7, Kernel: 3.10.0-514.16.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware RAID10, HDD, MDADM, Hypervizor: Processor: 2 x Intel Xeon L5640 @ 2.27GHz (24 Cores), Motherboard: Supermicro X8DT6, Chipset: Intel 5520 I/O + ICH10R, Memory: 12 x 4096 MB DDR3-1066MHz Micron 36JSZF51272PZ1G1F1, Disk: 120GB TEAM L3 SSD 120G + 3 x 4001GB Western Digital WD40EZRZ-00W + 250GB Samsung SSD 850 + 4 x 1999GB MR9266-8i, Graphics: Matrox s MGA G200eW WPCM450, Network: Emulex OneConnect 10Gb NIC OS: CentOS 7.3.1611, Kernel: 3.10.0-514.26.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1280x1024 RAID10, HDD, MDADM, KVM BASED VIRTIO: Processor: 8 x Intel Xeon L5640 @ 2.27GHz (8 Cores), Motherboard: Red Hat KVM, Chipset: Intel 440FX- 82441FX PMC, Memory: 1 x 8192 MB RAM, Disk: 200GB, Graphics: Cirrus Logic GD 5446, Network: Intel 82540EM Gigabit OS: CentOS Linux 7, Kernel: 3.10.0-514.16.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768, System Layer: KVM RAID5, HDD, MD KVM BASED Virtualization: Processor: 8 x Intel Xeon L5640 @ 2.27GHz (8 Cores), Motherboard: Red Hat KVM, Chipset: Intel 440FX- 82441FX PMC, Memory: 1 x 8192 MB RAM, Disk: 7450GB, Graphics: Cirrus Logic GD 5446, Network: Intel 82540EM Gigabit OS: CloudLinux 7.3, Kernel: 3.10.0-614.10.2.lve1.4.56.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768, System Layer: KVM RAID10, HDD, 9266i, KVM BASED VIRTIO: Processor: 8 x Intel Xeon L5640 @ 2.27GHz (8 Cores), Motherboard: Red Hat KVM, Chipset: Intel 440FX- 82441FX PMC, Memory: 1 x 8192 MB RAM, Disk: 3722GB, Graphics: Cirrus Logic GD 5446, Network: Intel 82540EM Gigabit OS: CentOS Linux 7, Kernel: 3.10.0-514.16.1.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1024x768, System Layer: KVM RAID 10, HDD, 9266i, Hypervizor: Processor: 2 x Intel Xeon L5640 @ 2.27GHz (24 Cores), Motherboard: Supermicro X8DT6, Chipset: Intel 5520 I/O + ICH10R, Memory: 12 x 4096 MB DDR3-1066MHz Micron 36JSZF51272PZ1G1F1, Disk: 120GB TEAM L3 SSD 120G + 3 x 4001GB Western Digital WD40EZRZ-00W + 250GB Samsung SSD 850 + 3998GB MR9266-8i, Graphics: Matrox s MGA G200eW WPCM450, Network: Emulex OneConnect 10Gb NIC OS: CentOS 7.3.1611, Kernel: 3.10.0-514.26.2.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1280x1024 AIO-Stress 0.21 Test: Random Write MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 317.34 |====== RAID10, HDD, MDADM, Hypervizor .......... 1424.06 |=========================== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 701.00 |============= RAID5, HDD, MD KVM BASED Virtualization . 323.78 |====== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 473.76 |========= RAID 10, HDD, 9266i, Hypervizor ......... 1454.99 |============================ FFmpeg 2.8.1 H.264 HD To NTSC DV Seconds < Lower Is Better VMWare MDADM RAID10 HDD ................. 18.77 |======================== RAID10, HDD, MDADM, Hypervizor .......... 22.70 |============================= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 20.55 |========================== RAID5, HDD, MD KVM BASED Virtualization . 23.37 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 22.33 |============================= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 1.46 |= RAID10, HDD, MDADM, Hypervizor .......... 1.41 |= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 47.30 |========================== RAID5, HDD, MD KVM BASED Virtualization . 22.40 |============ RAID10, HDD, 9266i, KVM BASED VIRTIO .... 55.24 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 2.07 |= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 364 |= RAID10, HDD, MDADM, Hypervizor .......... 352 |= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 11826 |========================== RAID5, HDD, MD KVM BASED Virtualization . 5600 |============ RAID10, HDD, 9266i, KVM BASED VIRTIO .... 13809 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 517 |= Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 415.60 |=== RAID10, HDD, MDADM, Hypervizor .......... 410.31 |=== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 3234.35 |==================== RAID5, HDD, MD KVM BASED Virtualization . 3441.00 |====================== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 4460.27 |============================ RAID 10, HDD, 9266i, Hypervizor ......... 312.74 |== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 25 |=== RAID10, HDD, MDADM, Hypervizor .......... 25 |=== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 202 |======================= RAID5, HDD, MD KVM BASED Virtualization . 215 |========================= RAID10, HDD, 9266i, KVM BASED VIRTIO .... 278 |================================ RAID 10, HDD, 9266i, Hypervizor ......... 19 |== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 2.31 |= RAID10, HDD, MDADM, Hypervizor .......... 2.34 |= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 34.48 |===================== RAID5, HDD, MD KVM BASED Virtualization . 6.74 |==== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 49.69 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 2.32 |= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 577 |= RAID10, HDD, MDADM, Hypervizor .......... 585 |= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 8620 |===================== RAID5, HDD, MD KVM BASED Virtualization . 1685 |==== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 12423 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 579 |= Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 272.13 |== RAID10, HDD, MDADM, Hypervizor .......... 257.40 |== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 1837.47 |================= RAID5, HDD, MD KVM BASED Virtualization . 191.47 |== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 3117.50 |============================ RAID 10, HDD, 9266i, Hypervizor ......... 212.11 |== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 16 |=== RAID10, HDD, MDADM, Hypervizor .......... 15 |== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 114 |=================== RAID5, HDD, MD KVM BASED Virtualization . 11 |== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 194 |================================ RAID 10, HDD, 9266i, Hypervizor ......... 12 |== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 38.05 |============ RAID10, HDD, MDADM, Hypervizor .......... 84.27 |=========================== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 50.88 |================ RAID5, HDD, MD KVM BASED Virtualization . 42.43 |============== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 53.84 |================= RAID 10, HDD, 9266i, Hypervizor ......... 93.32 |============================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 9513 |============ RAID10, HDD, MDADM, Hypervizor .......... 21067 |=========================== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 12719 |================ RAID5, HDD, MD KVM BASED Virtualization . 10608 |============== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 13460 |================= RAID 10, HDD, 9266i, Hypervizor ......... 23330 |============================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 346.13 |== RAID10, HDD, MDADM, Hypervizor .......... 855.05 |===== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 3261.92 |==================== RAID5, HDD, MD KVM BASED Virtualization . 3490.00 |====================== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 4473.63 |============================ RAID 10, HDD, 9266i, Hypervizor ......... 328.04 |== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 20 |== RAID10, HDD, MDADM, Hypervizor .......... 52 |====== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 203 |======================= RAID5, HDD, MD KVM BASED Virtualization . 217 |========================= RAID10, HDD, 9266i, KVM BASED VIRTIO .... 279 |================================ RAID 10, HDD, 9266i, Hypervizor ......... 20 |== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 19.05 |=========== RAID10, HDD, MDADM, Hypervizor .......... 22.60 |============= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 40.55 |======================= RAID5, HDD, MD KVM BASED Virtualization . 20.15 |=========== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 53.40 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 24.52 |============== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 4761 |=========== RAID10, HDD, MDADM, Hypervizor .......... 5650 |============= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 10136 |======================= RAID5, HDD, MD KVM BASED Virtualization . 5037 |=========== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 13349 |============================== RAID 10, HDD, 9266i, Hypervizor ......... 6128 |============== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory MB/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 293.94 |=== RAID10, HDD, MDADM, Hypervizor .......... 287.21 |=== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 1170.58 |========== RAID5, HDD, MD KVM BASED Virtualization . 144.48 |= RAID10, HDD, 9266i, KVM BASED VIRTIO .... 3135.28 |============================ RAID 10, HDD, 9266i, Hypervizor ......... 226.56 |== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Sync - Buffered: No - Direct: Yes - Block Size: 16MB - Disk Target: Default Test Directory IOPS > Higher Is Better VMWare MDADM RAID10 HDD ................. 17 |=== RAID10, HDD, MDADM, Hypervizor .......... 17 |=== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 72 |============ RAID5, HDD, MD KVM BASED Virtualization . 8 |= RAID10, HDD, 9266i, KVM BASED VIRTIO .... 196 |================================ RAID 10, HDD, 9266i, Hypervizor ......... 13 |== FS-Mark 3.3 Test: 1000 Files, 1MB Size Files/s > Higher Is Better VMWare MDADM RAID10 HDD ................. 181.68 |============================= RAID10, HDD, MDADM, Hypervizor .......... 181.97 |============================= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 137.22 |====================== RAID5, HDD, MD KVM BASED Virtualization . 16.20 |=== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 106.53 |================= RAID 10, HDD, 9266i, Hypervizor ......... 112.13 |================== Gzip Compression 2GB File Compression Seconds < Lower Is Better VMWare MDADM RAID10 HDD ................. 21.05 |===================== RAID10, HDD, MDADM, Hypervizor .......... 21.06 |===================== RAID10, HDD, MDADM, KVM BASED VIRTIO .... 27.59 |============================ RAID5, HDD, MD KVM BASED Virtualization . 29.94 |============================== RAID10, HDD, 9266i, KVM BASED VIRTIO .... 27.57 |============================ RAID 10, HDD, 9266i, Hypervizor ......... 21.00 |===================== SQLite 3.8.10.2 Test Target: Default Test Directory Seconds < Lower Is Better VMWare MDADM RAID10 HDD ................. 18.82 |= RAID10, HDD, MDADM, Hypervizor .......... 16.55 |= RAID10, HDD, MDADM, KVM BASED VIRTIO .... 27.16 |= RAID5, HDD, MD KVM BASED Virtualization . 904.31 |============================= RAID10, HDD, 9266i, KVM BASED VIRTIO .... 32.88 |= RAID 10, HDD, 9266i, Hypervizor ......... 14.35 |