FNOX SAN Testing FIO FNOX SAN Testing fio disk V7000gen2-ssd-raid5-comp: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware V7000gen2-ssd-raid5: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware V7000-hdd-raid10: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware V7000gen2-ssd-raid10: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware V7000gen2-hdd-raid10: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware V7000gen2-hdd-raid10-comp: Processor: Intel Xeon E5-2660 0 @ 2.20GHz (4 Cores), Motherboard: Intel 440BX, Memory: 1 x 4096 MB DRAM, Disk: 21GB Virtual disk + 11GB Virtual disk OS: CentOS Linux 7, Kernel: 3.10.0-229.el7.x86_64 (x86_64), Compiler: GCC 4.8.5 20150623, File-System: xfs, Screen Resolution: 1176x885, System Layer: VMware Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS IOPS > Higher Is Better V7000gen2-ssd-raid5-comp .. 51346 |================================== V7000gen2-ssd-raid5 ....... 50552 |================================= V7000-hdd-raid10 .......... 11189 |======= V7000gen2-ssd-raid10 ...... 67017 |============================================ V7000gen2-hdd-raid10 ...... 38157 |========================= V7000gen2-hdd-raid10-comp . 56896 |===================================== Flexible IO Tester 2.1.13 Type: Random Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s MB/s > Higher Is Better V7000gen2-ssd-raid5-comp .. 206.38 |================================ V7000gen2-ssd-raid5 ....... 205.49 |================================ V7000-hdd-raid10 .......... 151.02 |======================== V7000gen2-ssd-raid10 ...... 274.17 |=========================================== V7000gen2-hdd-raid10 ...... 203.35 |================================ V7000gen2-hdd-raid10-comp . 232.39 |==================================== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS IOPS > Higher Is Better V7000gen2-ssd-raid5-comp .. 19617 |================ V7000gen2-ssd-raid5 ....... 38763 |================================ V7000-hdd-raid10 .......... 13730 |=========== V7000gen2-ssd-raid10 ...... 53830 |============================================ V7000gen2-hdd-raid10 ...... 31914 |========================== V7000gen2-hdd-raid10-comp . 17517 |============== Flexible IO Tester 2.1.13 Type: Random Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s MB/s > Higher Is Better V7000gen2-ssd-raid5-comp .. 78.88 |================ V7000gen2-ssd-raid5 ....... 154.75 |=============================== V7000-hdd-raid10 .......... 55.20 |=========== V7000gen2-ssd-raid10 ...... 217.09 |=========================================== V7000gen2-hdd-raid10 ...... 128.91 |========================== V7000gen2-hdd-raid10-comp . 72.97 |============== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS IOPS > Higher Is Better V7000gen2-ssd-raid5-comp .. 68145 |================================== V7000gen2-ssd-raid5 ....... 70857 |=================================== V7000-hdd-raid10 .......... 58762 |============================= V7000gen2-ssd-raid10 ...... 88290 |============================================ V7000gen2-hdd-raid10 ...... 71767 |==================================== V7000gen2-hdd-raid10-comp . 76378 |====================================== Flexible IO Tester 2.1.13 Type: Sequential Read - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s MB/s > Higher Is Better V7000gen2-ssd-raid5-comp .. 285.52 |=================================== V7000gen2-ssd-raid5 ....... 287.98 |=================================== V7000-hdd-raid10 .......... 220.02 |=========================== V7000gen2-ssd-raid10 ...... 352.19 |=========================================== V7000gen2-hdd-raid10 ...... 287.98 |=================================== V7000gen2-hdd-raid10-comp . 305.22 |===================================== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: IOPS IOPS > Higher Is Better V7000gen2-ssd-raid5-comp .. 28274 |=================== V7000gen2-ssd-raid5 ....... 44469 |============================== V7000-hdd-raid10 .......... 15701 |========== V7000gen2-ssd-raid10 ...... 66058 |============================================ V7000gen2-hdd-raid10 ...... 44938 |============================== V7000gen2-hdd-raid10-comp . 15079 |========== Flexible IO Tester 2.1.13 Type: Sequential Write - IO Engine: Libaio - Buffered: No - Direct: Yes - Block Size: 4KB - Disk Target: /root/pgdisk - Result: MB/s MB/s > Higher Is Better V7000gen2-ssd-raid5-comp .. 112.66 |================== V7000gen2-ssd-raid5 ....... 177.95 |============================= V7000-hdd-raid10 .......... 65.52 |=========== V7000gen2-ssd-raid10 ...... 263.43 |=========================================== V7000gen2-hdd-raid10 ...... 181.47 |============================== V7000gen2-hdd-raid10-comp . 62.04 |==========